Implementing a Laboratory Automation System: Experience of a Large Clinical Laboratory
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Laboratories today face increasing pressure to automate their operations as they are challenged by a continuing increase in workload, need to reduce expenditure, and difficulties in recruitment of experienced technical staff. Was the implementation of a laboratory automation system (LAS) in the Clinical Biochemistry Laboratory at Singapore General Hospital successful? There is no simple answer, so the following topics comparing and contrasting pre- and post-LAS have been explored: turnaround time (TAT), laboratory errors, and staff satisfaction. The benefits and limitations of LAS from the laboratory experience were also reviewed. The mean TAT for both stat and routine samples decreased post-LAS (30% and 13.4%, respectively). In the 90th percentile TAT chart, a 29% reduction was seen in the processing of stat samples on the LAS. However, no significant difference in the 90th percentile TAT was observed with routine samples. It was surprising to note that laboratory errors increased post-LAS. Considerable effort was needed to overcome the initial difficulties associated with adjusting to a new system, new software, and new working procedures. Although some of the known advantages and limitations of LAS have been validated, the claimed benefits such as improvements in TAT, laboratory errors, and staff morale were not evident in the initial months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Cited by
Automation and artificial intelligence in the clinical laboratory
Naugler, C., & Church, D. L. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1561640 · Cited by 112
“In the implementation period when staff are becoming familiarized with a total automation system, there may also be a “ bleed-in ” period where laboratory errors increase [31].”
BackgroundIalongo, C., Porzio, O., Giambini, I., & Bernardini, S. (2016) · SLAS Technology · doi:10.1177/2211068215581488 · Cited by 42
Angeletti, S., De Cesaris, M., Hart, J. G., Urbano, M., Vitali, M. A., Fragliasso, F., & Dicuonzo, G. (2015) · SLAS Technology · doi:10.1177/2211068214566458 · Cited by 38
“Laboratory automation has been described as an important means of improving the efficiency of the laboratory and TAT observance.(9,13,14) In the present study, TAT was analyzed before and after laboratory automation implementation to evaluate the impact of automation on stat samples management.”
MethodResult
Metadata
- Authors
- Lam, C. W., & Jacob, E.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2012-02
- Volume
- 17
- Issue
- 1
- Pages
- 16-23
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W1981302947
- Cited by
- 41
- References
- 1
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementing a Laboratory Automation System: Experience of a Large Clinical Laboratory. https://app.cochat.ai/papers/10.1177/2211068211430186
- The paper
- Lam, C. W., & Jacob, E. (2012). Implementing a Laboratory Automation System: Experience of a Large Clinical Laboratory. SLAS Technology. https://doi.org/10.1177/2211068211430186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.