Silicone Oil Droplets are More Common in Fluid From BD Insulin Syringes as Compared to Other Syringes
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: During 2016 and 2017, numerous retina specialists reported silicone oil droplets after intravitreal injection, primarily associated with insulin syringes with a fixed needle. By contrast, adverse events were relatively rare for tuberculin syringes. We hypothesized that fixed-needle syringe injections have more silicone droplets due to the lack of dead space at the syringe–needle junction. Methods: Fluid from Becton Dickenson (BD) insulin syringes, BD tuberculin syringes, Henke Sass Wolf (HSW) insulin syringes, and HSW silicone-free syringes was examined microscopically for silicone oil droplets. Fluid was sampled at the beginning, middle, and end of injection; and droplets were photographed and quantified. Results: Silicone oil droplets were identified in 30% of the BD insulin syringes, measuring 0.9 ± 0.2 mm 3; no oil droplets were found in BD tuberculin syringes or HSW silicone-free syringes (analysis of variance, P < .05). All 6 samples with silicone oil droplets were from the end of injection (full depression of the plunger), while samples from the beginning and middle of injections did not have droplets. Challenging syringes with extra silicone oil resulted in increased droplets for fixed-needle syringes (but not for syringes with detachable needles). Conclusion: Significant silicone oil droplets were present in BD insulin syringes and were expressed at the end of injection (with plunger depressed maximally), supporting the hypothesis that insulin syringe injections have more droplets due to the lack of dead space where the plunger meets the hub of the needle. However, there are additional factors such as the amount or type of silicone lubricant in a syringe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liu, L., Ammar, D. A., Ross, L. A., Mandava, N., Kahook, M. Y., & Carpenter, J. F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6431 · Cited by 199
Cited by
Melo, G. B., Cruz, N. F. S. D., Emerson, G. G., Rezende, F. A., Meyer, C. H., Uchiyama, S., Carpenter, J., Shiroma, H. F., Farah, M. E., Maia, M., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100862 · Cited by 114
Self-citationComplications of intravitreal injections: 2022
Patel, D., Patel, S. N., Chaudhary, V., & Garg, S. J. (2022) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000850 · Cited by 92
Release of silicone oil droplets from syringes
Melo, G. B., Dias Junior, C. D. S., Carvalho, M. R., Cardoso, A. L., Morais, F. B., Figueira, A. C. M., Lima Filho, A. A. S., Emerson, G. G., & Maia, M. (2019) · International Journal of Retina and Vitreous · doi:10.1186/s40942-018-0153-8 · Cited by 50
Self-citationLode, H. E., Gjølberg, T. T., Foss, S., Sivertsen, M. S., Brustugun, J., Andersson, Y., Jørstad, Ø. K., Moe, M. C., & Andersen, J. T. (2019) · Scientific Reports · doi:10.1038/s41598-019-54226-7 · Cited by 40
Agitation of the syringe and release of silicone oil
Dias Júnior, C. D. S., Cardoso, A. L., Figueiredo, A. G. D. A., Ota, S., & Melo, G. B. (2020) · Eye · doi:10.1038/s41433-020-0800-9 · Cited by 17
Metadata
- Authors
- Emerson, G. G.
- Venue
- Journal of VitreoRetinal Diseases
- Publisher
- SAGE Publications
- Published
- 2017-10-11
- Volume
- 1
- Issue
- 6
- Pages
- 401-406
- ISSN
- 2474-1264 (ISSN-L)
- 2474-1272
- OpenAlex
- W2763443722
- Cited by
- 24
- References
- 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Silicone Oil Droplets are More Common in Fluid From BD Insulin Syringes as Compared to Other Syringes. https://app.cochat.ai/papers/10.1177/2474126417735963
- The paper
- Emerson, G. G. (2017). Silicone Oil Droplets are More Common in Fluid From BD Insulin Syringes as Compared to Other Syringes. Journal of VitreoRetinal Diseases. https://doi.org/10.1177/2474126417735963
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.