The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A comparison of plaster, digital and reconstructed study model accuracy
Abstract
OBJECTIVES: To evaluate the accuracy and reproducibility of a three-dimensional (3D) optical laser-scanning device to record the surface detail of plaster study models. To determine the accuracy of physical model replicas constructed from the 3D digital files. DESIGN AND SETTING: A method comparison study using 30 dental study models held in the Orthodontic Department, School of Dentistry, Cardiff University. MATERIALS AND METHODS: Each model was captured three-dimensionally, using a commercially available Minolta VIVID 900 non-contact 3D surface laser scanner (Konica Minolta Inc., Tokyo, Japan), a rotary stage and Easy3DScan integrating software (TowerGraphics, Lucca, Italy). Linear measurements were recorded between landmarks, directly on each of the plaster models and indirectly on the 3D digital surface models, on two separate occasions by a single examiner. Physical replicas of two digital models were also reconstructed from their scanned data files, using a rapid prototyping (RP) manufacturing process, and directly evaluated for dimensional accuracy. RESULTS: The mean difference between measurements made directly on the plaster models and those made on the 3D digital surface models was 0.14 mm, and was not statistically significant (P = 0.237). The mean difference between measurements made on both the plaster and virtual models and those on the RP models, in the z plane was highly statistically significant (P <0.001). CONCLUSIONS: The Minolta VIVID 900 digitizer is a reliable device for capturing the surface detail of plaster study models three-dimensionally in a digital format but physical models of appropriate detail and accuracy cannot be reproduced from scanned data using the RP technique described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Advancements in CAD/CAM technology: Options for practical implementation
Alghazzawi, T. F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.01.003 · Cited by 637
Current and emerging applications of 3D printing in medicine
Liaw, C.-Y., & Guvendiren, M. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7279 · Cited by 604
Hazeveld, A., Huddleston Slater, J. J. R., & Ren, Y. (2014) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.05.011 · Cited by 357
Metadata
- Authors
- Keating, A. P., Knox, J., Bibb, R., & Zhurov, A. I.
- Venue
- Journal of Orthodontics
- Publisher
- Informa UK Limited
- Published
- 2008-09
- Volume
- 35
- Issue
- 3
- Pages
- 191-201
- ISSN
- 1465-3125 (ISSN-L)
- 1465-3133
- OpenAlex
- W2024153804
- Cited by
- 225
- References
- 2
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of plaster, digital and reconstructed study model accuracy. https://app.cochat.ai/papers/10.1179/146531207225022626
- The paper
- Keating, A. P., Knox, J., Bibb, R., & Zhurov, A. I. (2008). A comparison of plaster, digital and reconstructed study model accuracy. Journal of Orthodontics. https://doi.org/10.1179/146531207225022626
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.