Abstract
An Fe–35 wt-%Mn alloy, aimed to be used as a metallic degradable biomaterial for stent applications, was prepared via a powder metallurgy route. The effects of processing conditions on the microstructure, mechanical properties, magnetic susceptibility and corrosion behaviour were investigated and the results were compared to those of the SS316L alloy, a gold standard for stent applications. The Fe35Mn alloy was found to be essentially austenitic with fine MnO particles aligned along the rolling direction. The alloy is ductile with a strength approaching that of wrought SS316L. It exhibits antiferromagnetic behaviour and its magnetic susceptibility is not altered by plastic deformation, providing an excellent MRI compatibility. Its corrosion rate was evaluated in a modified Hank's solution, and found superior to that of pure iron (slow in vivo degradation rate). In conclusion, the mechanical, magnetic and corrosion characteristics of the Fe35Mn alloy are considered suitable for further development of a new class of degradable metallic biomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Smithells Metals Reference Book
(1992) · Elsevier eBooks · doi:10.1016/c2009-0-25363-3 · Cited by 3,613
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.029 · Cited by 558
Kujala, S., Ryhänen, J., Danilov, A., & Tuukkanen, J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00359-4 · Cited by 284
McGregor, D. B., Baan, R. A., Partensky, C., Rice, J. M., & Wilbourn, J. D. (2000) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00312-3 · Cited by 215
Mumtaz, K., Takahashi, S., Echigoya, J., Kamada, Y., Zhang, L. F., Kikuchi, H., Ara, K., & Sato, M. (2003) · Journal of Materials Science · doi:10.1023/b:jmsc.0000007731.38154.e1 · Cited by 121
Cotes, S. M., Guillermet, A. F., & Sade, M. L. (2004) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-004-0111-y · Cited by 88
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Self-citationBiodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Self-citationBiodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Current status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Self-citationLiu, B., & Zheng, Y. F. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.001 · Cited by 396
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Self-citationThe role of additive manufacturing for biomedical applications: A critical review
Kumar, R., Kumar, M., & Chohan, J. S. (2021) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2021.02.022 · Cited by 367
Current status and perspectives of zinc-based absorbable alloys for biomedical applications
Hernández-Escobar, D., Champagne, S., Yilmazer, H., Dikici, B., Boehlert, C. J., & Hermawan, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.034 · Cited by 309
Self-citationBiodegradable metallic bone implants
Shuai, C., Li, S., Peng, S., Feng, P., Lai, Y., & Gao, C. (2019) · Materials Chemistry Frontiers · doi:10.1039/c8qm00507a · Cited by 275
Various manufacturing methods and ideal properties of scaffolds for tissue engineering applications
Suamte, L., Tirkey, A., Barman, J., & Jayasekhar Babu, P. (2023) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2022.100011 · Cited by 259
Novel processing of iron–manganese alloy-based biomaterials by inkjet 3-D printing
Chou, D.-T., Wells, D., Hong, D., Lee, B., Kuhn, H., & Kumta, P. N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.04.016 · Cited by 259
Metals for Biomedical Applications
Hermawan, H., Ramdan, D., & P. Djuansjah, J. R. (2011) · Biomedical Engineering - From Theory to Applications · doi:10.5772/19033 · Cited by 238
Self-citationBinder-jetting 3D printing and alloy development of new biodegradable Fe-Mn-Ca/Mg alloys
Hong, D., Chou, D.-T., Velikokhatnyi, O. I., Roy, A., Lee, B., Swink, I., Issaev, I., Kuhn, H. A., & Kumta, P. N. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.08.032 · Cited by 234
Porous Biodegradable Metals for Hard Tissue Scaffolds: A Review
Yusop, A. H., Bakir, A. A., Shaharom, N. A., Abdul Kadir, M. R., & Hermawan, H. (2012) · International Journal of Biomaterials · doi:10.1155/2012/641430 · Cited by 225
“Magnesium- (Mg-) based and iron- (Fe-) based metals have been used, which include Mg-RE (rare earth elements) [29–33], Mg-Ca- [34, 35], pure Fe [36, 37], Fe-Mn alloys [38, 39], and Fe foam for bone replacement scaffold [40].”
MethodSelf-citationMetallic Architectures from 3D‐Printed Powder‐Based Liquid Inks
Jakus, A. E., Taylor, S. L., Geisendorfer, N. R., Dunand, D. C., & Shah, R. N. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201503921 · Cited by 209
In Vitro Cytotoxicity, Adhesion, and Proliferation of Human Vascular Cells Exposed to Zinc
Shearier, E. R., Bowen, P. K., He, W., Drelich, A., Drelich, J., Goldman, J., & Zhao, F. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00035 · Cited by 209
A fully biodegradable and self-electrified device for neuroregenerative medicine
Wang, L., Lu, C., Yang, S., Sun, P., Wang, Y., Guan, Y., Liu, S., Cheng, D., Meng, H., Wang, Q., et al. (2020) · Science Advances · doi:10.1126/sciadv.abc6686 · Cited by 195
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
“In particular, there has been a great deal of focus on magnesium (Mg) [13,14] and iron (Fe) [15,16] and their alloys as candidate materials.”
BackgroundHagihara, K., Okubo, M., Yamasaki, M., & Nakano, T. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.03.019 · Cited by 188
Moravej, M., Purnama, A., Fiset, M., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.01.008 · Cited by 184
Self-citationDesign, printing, and engineering of regenerative biomaterials for personalized bone healthcare
Jia, Z., Xu, X., Zhu, D., & Zheng, Y. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101072 · Cited by 176
Continuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Gastaldi, D., Sassi, V., Petrini, L., Vedani, M., Trasatti, S., & Migliavacca, F. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.003 · Cited by 173
Recent advancements in Fe-based biodegradable materials for bone repair
Gorejová, R., Haverová, L., Oriňaková, R., Oriňak, A., & Oriňak, M. (2019) · Journal of Materials Science · doi:10.1007/s10853-018-3011-z · Cited by 166
Biodegradable stents for coronary artery disease treatment: Recent advances and future perspectives
Hu, T., Yang, C., Lin, S., Yu, Q., & Wang, G. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.04.100 · Cited by 163
Purnama, A., Hermawan, H., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.027 · Cited by 161
Self-citation
Metadata
- Authors
- Hermawan, H., Alamdari, H., Mantovani, D., & Dubé, D.
- Venue
- Powder Metallurgy
- Publisher
- SAGE Publications
- Published
- 2008-03
- Volume
- 51
- Issue
- 1
- Pages
- 38-45
- ISSN
- 0032-5899 (ISSN-L)
- 1743-2901
- OpenAlex
- W1975578424
- Cited by
- 287
- References
- 11
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.