Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 214

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Electrofinishing of metals using eutectic based ionic liquids

Open access
Abbott, A. P., Ryder, K. S., König, U.·2008·Transactions of the IMF

Abstract

Ionic liquids are molten salts that have low melting points. This review concentrates upon eutectic mixtures of quaternary ammonium salts and metal salts (usually halides). These so-called eutectic based ionic liquids can be used for the electrodeposition and dissolution of a wide range of metals and alloys. The review highlights the technological challenges involved in the application of ionic liquids to metal finishing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1179/174591908x327590

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 214

Metadata

Authors
Abbott, A. P., Ryder, K. S., & König, U.
Venue
Transactions of the IMF
Published
2008-07
Volume
86
Issue
4
Pages
196-204
ISSN
  • 0020-2967 (ISSN-L)
  • 1745-9192
OpenAlex
W1999308483
Cited by
214
References
5
FWCI
6.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrofinishing of metals using eutectic based ionic liquids. https://app.cochat.ai/papers/10.1179/174591908x327590
The paper
Abbott, A. P., Ryder, K. S., & König, U. (2008). Electrofinishing of metals using eutectic based ionic liquids. Transactions of the IMF. https://doi.org/10.1179/174591908x327590

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.