CPAP: a guide for clinicians in developing countries
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Despite the provision of oxygen, antibiotics and treatment guidelines, the case fatality rate for hypoxaemic pneumonia is still high in many hospitals in developing countries. Methods of delivering continuous positive airway pressure (CPAP) are now available which are simple to use, safe and relatively inexpensive. This paper describes two methods which may be appropriate where resources are limited: (i) bubble-CPAP using oxygen concentrators with an air-oxygen mix function and low resistance nasal oxygen prongs, and (ii) high-flow nasal cannula oxygen therapy. More research is needed on the implementation, cost and effectiveness of CPAP in the management of pneumonia and in neonatal care in developing countries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction of bubble CPAP in a teaching hospital in Malawi
Van Den Heuvel, M., Blencowe, H., Mittermayer, K., Rylance, S., Couperus, A., Heikens, G. T., & Bandsma, R. H. J. (2011) · Annals of Tropical Paediatrics · doi:10.1179/1465328110y.0000000001 · Cited by 52
Cited by
Chisti, M. J., Salam, M. A., Smith, J. H., Ahmed, T., Pietroni, M. A. C., Shahunja, K. M., Shahid, A. S. M. S. B., Faruque, A. S. G., Ashraf, H., Bardhan, P. K., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60249-5 · Cited by 255
Self-citationMartin, S., Duke, T., & Davis, P. (2014) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/archdischild-2013-305519 · Cited by 129
Self-citationDewez, J. E., & van den Broek, N. (2017) · Tropical Doctor · doi:10.1177/0049475516630210 · Cited by 48
“CPAP is the only intervention which has the potential to be implemented on a large scale in LMICs as simple, safe and relatively inexpensive CPAP devices have been developed recently.(3) Continuous positive airway pressure (CPAP)”
BackgroundInfluentialEkhaguere, O. A., Mairami, A. B., & Kirpalani, H. (2019) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2018.04.004 · Cited by 42
Dewez, J. E., Chellani, H., Nangia, S., Metsis, K., Smith, H., Mathai, M., & van den Broek, N. (2018) · BMC Pediatrics · doi:10.1186/s12887-018-1311-8 · Cited by 20
Improved Neonatal Mortality at a District Hospital in Aweil, South Sudan
Thomson, J., Schaefer, M., Caminoa, B., Kahindi, D., & Hurtado, N. (2016) · Journal of Tropical Pediatrics · doi:10.1093/tropej/fmw071 · Cited by 15
Metadata
- Authors
- Duke, T.
- Venue
- Paediatrics and International Child Health
- Publisher
- Informa UK Limited
- Published
- 2013-12-06
- Volume
- 34
- Issue
- 1
- Pages
- 3-11
- ISSN
- 2046-9047 (ISSN-L)
- 2046-9055
- OpenAlex
- W2074989110
- Cited by
- 75
- References
- 1
- Type
- book review
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.