The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance
Abstract
Measurement of liver iron concentration (LIC) is necessary for a range of iron-loading disorders such as hereditary hemochromatosis, thalassemia, sickle cell disease, aplastic anemia, and myelodysplasia. Currently, chemical analysis of needle biopsy specimens is the most common accepted method of measurement. This study presents a readily available noninvasive method of measuring and imaging LICs in vivo using clinical 1.5-T magnetic resonance imaging units. Mean liver proton transverse relaxation rates (R2) were measured for 105 humans. A value for the LIC for each subject was obtained by chemical assay of a needle biopsy specimen. High degrees of sensitivity and specificity of R2 to biopsy LICs were found at the clinically significant LIC thresholds of 1.8, 3.2, 7.0, and 15.0 mg Fe/g dry tissue. A calibration curve relating liver R2 to LIC has been deduced from the data covering the range of LICs from 0.3 to 42.7 mg Fe/g dry tissue. Proton transverse relaxation rates in aqueous paramagnetic solutions were also measured on each magnetic resonance imaging unit to ensure instrument-independent results. Measurements of proton transverse relaxivity of aqueous MnCl2 phantoms on 13 different magnetic resonance imaging units using the method yielded a coefficient of variation of 2.1%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Magnetic-Susceptibility Measurement of Human Iron Stores
Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M. (1982) · New England Journal of Medicine · doi:10.1056/nejm198212303072703 · Cited by 367
Cited by
Taher, A. T., Weatherall, D. J., & Cappellini, M. D. (2018) · The Lancet · doi:10.1016/s0140-6736(17)31822-6 · Cited by 807
Cao, A., & Galanello, R. (2010) · Genetics in Medicine · doi:10.1097/gim.0b013e3181cd68ed · Cited by 722
Brissot, P., Pietrangelo, A., Adams, P. C., de Graaff, B., McLaren, C. E., & Loréal, O. (2018) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2018.16 · Cited by 430
A phase 3 trial of luspatercept in patients with transfusion-dependent β-thalassemia.
Cappellini, M. D., Viprakasit, V., Taher, A. T., Georgiev, P., Kuo, K. H. M., Coates, T., Voskaridou, E., Liew, H.-K., Pazgal-Kobrowski, I., Forni, G. L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910182 · Cited by 332
Hemochromatosis: An endocrine liver disease
Pietrangelo, A. (2007) · Hepatology · doi:10.1002/hep.21886 · Cited by 212
Metadata
- Authors
- St. Pierre, T. G., Clark, P. R., Chua-anusorn, W., Fleming, A. J., Jeffrey, G. P., Olynyk, J. K., Pootrakul, P., Robins, E., & Lindeman, R.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 2005-01-15
- Volume
- 105
- Issue
- 2
- Pages
- 855-861
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2108344872
- Cited by
- 909
- References
- 2
- FWCI
- 15.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.