Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 388

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Desirable performance characteristics for BCR-ABL measurement on an international reporting scale to allow consistent interpretation of individual patient response and comparison of response rates between clinical trials

Open access
Branford, Susan, Fletcher, Linda, Cross, Nicholas C. P., Müller, Martin C., Hochhaus, Andreas, Kim, Dong-Wook, Radich, Jerald P., Saglio, Giuseppe, Pane, Fabrizio, Kamel-Reid, Suzanne, Wang, Y. Lynn, Press, Richard D., Lynch, Kevin, Rudzki, Zbigniew, Goldman, John M., Hughes, Timothy·2008·Blood

Abstract

An international basis for comparison of BCR-ABL mRNA levels is required for the common interpretation of data derived from individual laboratories. This will aid clinical decisions for individual patients with chronic myeloid leukemia (CML) and assist interpretation of results from clinical studies. We aligned BCR-ABL values generated by 38 laboratories to an international scale (IS) where a major molecular response (MMR) is 0.1% or less. Alignment was achieved by application of laboratory-specific conversion factors calculated by comparisons performed with patient samples against a reference method. A validation procedure was completed for 19 methods. We determined performance characteristics (bias and precision) for consistent interpretation of MMR after IS conversion. When methods achieved an average BCR-ABL difference of plus or minus 1.2-fold from the reference method and 95% limits of agreement within plus or minus 5-fold, the MMR concordance was 91%. These criteria were met by 58% of methods. When not met, the MMR concordance was 74% or less. However, irrespective of precision, when the bias was plus or minus 1.2-fold as achieved by 89% of methods, there was good agreement between the overall MMR rates. This indicates that the IS can deliver accurate comparison of molecular response rates between clinical trials when measured by different laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood-2008-04-150680

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 388

Metadata

Authors
Branford, S., Fletcher, L., Cross, N. C. P., Müller, M. C., Hochhaus, A., Kim, D.-W., Radich, J. P., Saglio, G., Pane, F., Kamel-Reid, S., Wang, Y. L., Press, R. D., Lynch, K., Rudzki, Z., Goldman, J. M., & Hughes, T.
Venue
Blood
Published
2008-10-15
Volume
112
Issue
8
Pages
3330-3338
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W1981809014
Cited by
388
References
38
FWCI
18.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Desirable performance characteristics for BCR-ABL measurement on an international reporting scale to allow consistent interpretation of individual patient response and comparison of response rates between clinical trials. https://app.cochat.ai/papers/10.1182/blood-2008-04-150680
The paper
Branford, S., Fletcher, L., Cross, N. C. P., Müller, M. C., Hochhaus, A., Kim, D.-W., Radich, J. P., Saglio, G., Pane, F., Kamel-Reid, S., Wang, Y. L., Press, R. D., Lynch, K., Rudzki, Z., Goldman, J. M., & Hughes, T. (2008). Desirable performance characteristics for BCR-ABL measurement on an international reporting scale to allow consistent interpretation of individual patient response and comparison of response rates between clinical trials. Blood. https://doi.org/10.1182/blood-2008-04-150680

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.