Bioengineered human vascular networks transplanted into secondary mice reconnect with the host vasculature and re-establish perfusion
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The ability to form anastomoses with the host circulation is essential for vascular networks incorporated within cell-seeded bioengineered tissues. Here, we tested whether and how rapidly human endothelial colony forming cell (ECFC)/mesenchymal progenitor cell (MPC)–derived bioengineered vessels, originally perfused in one mouse, could become reperfused in a secondary mouse. Using in vivo labeling with a systemically injected mixture of human- and murine-specific lectins, we demonstrate that ECFC/MPC blood vessels reconnect and are perfused at day 3 after transplantation. Furthermore, we quantified the longitudinal change in perfusion volume in the same implants before and after transplantation using contrast-enhanced micro-ultrasonic imaging. Perfusion was restored at day 3 after transplantation and increased with time, suggesting an important new feature of ECFC/MPC blood vessels: the bioengineered vessels can reconnect with the vasculature when transplanted to a new site. This feature extends the potential applications of this postnatal progenitor cell-based technology for transplantable large tissue-engineered constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Creation of long-lasting blood vessels
Koike, N., Fukumura, D., Gralla, O., Au, P., Schechner, J. S., & Jain, R. K. (2004) · Nature · doi:10.1038/428138a · Cited by 701
Cited by
3D bioprinting of collagen to rebuild components of the human heart
Lee, A., Hudson, A. R., Shiwarski, D. J., Tashman, J. W., Hinton, T. J., Yerneni, S., Bliley, J. M., Campbell, P. G., & Feinberg, A. W. (2019) · Science · doi:10.1126/science.aav9051 · Cited by 1,782
Consensus guidelines for the use and interpretation of angiogenesis assays
Nowak-Sliwinska, P., Alitalo, K., Allen, E., Anisimov, A., Aplin, A. C., Auerbach, R., Augustin, H. G., Bates, D. O., van Beijnum, J. R., Bender, R. H. F., et al. (2018) · Angiogenesis · doi:10.1007/s10456-018-9613-x · Cited by 590
Self-citationImaging challenges in biomaterials and tissue engineering
Appel, A. A., Anastasio, M. A., Larson, J. C., & Brey, E. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.033 · Cited by 273
Geometric control of vascular networks to enhance engineered tissue integration and function
Baranski, J. D., Chaturvedi, R. R., Stevens, K. R., Eyckmans, J., Carvalho, B., Solorzano, R. D., Yang, M. T., Miller, J. S., Bhatia, S. N., & Chen, C. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1217796110 · Cited by 267
Postischemic Revascularization: From Cellular and Molecular Mechanisms to Clinical Applications
Silvestre, J.-S., Smadja, D. M., & Lévy, B. I. (2013) · Physiological Reviews · doi:10.1152/physrev.00006.2013 · Cited by 255
Metadata
- Authors
- Kang, K.-T., Allen, P., & Bischoff, J.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 2011-12-15
- Volume
- 118
- Issue
- 25
- Pages
- 6718-6721
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W1986363111
- Cited by
- 77
- References
- 1
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioengineered human vascular networks transplanted into secondary mice reconnect with the host vasculature and re-establish perfusion. https://app.cochat.ai/papers/10.1182/blood-2011-08-375188
- The paper
- Kang, K.-T., Allen, P., & Bischoff, J. (2011). Bioengineered human vascular networks transplanted into secondary mice reconnect with the host vasculature and re-establish perfusion. Blood. https://doi.org/10.1182/blood-2011-08-375188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.