Characterization of ultrasound-potentiated fibrinolysis in vitro
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We have characterized the effects of ultrasound on fibrinolysis in vitro to investigate the mechanism of ultrasonic potentiation of fibrinolysis and to identify potentially useful ultrasound parameters for therapeutic application. Radiolabeled clots in thin walled tubes were exposed to ultrasound fields in a water bath at 37 degrees C, and lysis was measured by solubilization of radiolabel. Ultrasound accelerated lysis of plasma, whole blood, and purified fibrin clots mediated by recombinant tissue-type plasminogen activator (rt-PA), urokinase, or streptokinase, but ultrasound by itself caused no clot solubilization. The degree of ultrasonic potentiation was dependent on plasminogen activator concentration, increasing from 2.2-fold at a streptokinase concentration of 75 U/mL to 5.5-fold at 250 U/mL in a 1 MHz ultrasound field at 4 W/cm2. Ultrasound exposure resulted in heating due to absorption by the plastic tube, but the temperature increase was insufficient to account for the increase in clot lysis rate, indicating that the primary effect was nonthermal. Ultrasound did not accelerate hydrolysis of a peptide substrate by rt-PA and did not alter the rate of plasmic degradation of fibrinogen, indicating that the augmentation of enzymatic fibrinolysis required the presence of a fibrin gel. The acceleration of fibrinolysis by ultrasound was greater at higher intensities and duty cycles and was maximum at frequencies between 1 and 2.2 MHz, but decreased at 3.4 MHz. These findings suggest that ultrasound accelerates enzymatic fibrinolysis by increasing transport of reactants through a cavitation-related mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fraker, P. J., & Speck, J. C. (1978) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(78)91322-0 · Cited by 4,558
Bovill, E. G., Terrin, M. L., Stump, D. C., Berke, A. D., Frederick, M., Collen, D., Feit, F., Gore, J. M., Hillis, L. D., Lambrew, C. T., et al. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-115-4-256 · Cited by 479
Enhancement of fibrinolysis in vitro by ultrasound.
Francis, C. W., Onundarson, P. T., Carstensen, E. L., Blinc, A., Meltzer, R. S., Schwarz, K., & Marder, V. (1992) · Journal of Clinical Investigation · doi:10.1172/jci116088 · Cited by 234
Self-citationEffect of ultrasound on tissue-type plasminogen activator-induced thrombolysis.
Lauer, C. G., Burge, R., Tang, D. B., Bass, B. G., Gomez, E. R., & Alving, B. M. (1992) · Circulation · doi:10.1161/01.cir.86.4.1257 · Cited by 216
Weinstein, M., & Doolittle, R. F. (1972) · Biochimica et Biophysica Acta (BBA) - Enzymology · doi:10.1016/0005-2744(72)90250-1 · Cited by 126
Fibrin has larger pores when formed in the presence of erythrocytes
Carr, M. E., & Hardin, C. L. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.5.h1069 · Cited by 118
Ultrasonic microstreaming and related phenomena.
Nyborg, W. L. (1982) · Europe PMC (PubMed Central) · Cited by 111
Ultrasonically induced gas bubble production in agar based gels: Part I, experimental investigation
Daniels, S., Blondel, D., Crum, L. A., ter Haar, G., & DYSON, M. L. (1987) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(87)90179-7 · Cited by 38
Cited by
Ultrasound-Enhanced Systemic Thrombolysis for Acute Ischemic Stroke
Alexandrov, A. V., Molina, C. A., Grotta, J. C., Garami, Z., Ford, S. R., Alvarez-Sabin, J., Montaner, J., Saqqur, M., Demchuk, A. M., Moyé, L. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041175 · Cited by 1,046
Ultrasound accelerates transport of recombinant tissue plasminogen activator into clots
Francis, C. W., Blinc, A., Lee, S., & Cox, C. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00119-x · Cited by 365
Self-citationAlbumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis
Tachibana, K., & Tachibana, S. (1995) · Circulation · doi:10.1161/01.cir.92.5.1148 · Cited by 343
Encapsulated ultrasound microbubbles: Therapeutic application in drug/gene delivery
Liu, Y., Miyoshi, H., & Nakamura, M. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.05.018 · Cited by 319
Ultrasound Reversibly Disaggregates Fibrin Fibers
Braaten, J. V., Goss, R. A., & Francis, C. W. (1997) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1657688 · Cited by 279
Self-citation
Metadata
- Authors
- Blinc, A., Francis, C., Trudnowski, J., & Carstensen, E.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1993-05-15
- Volume
- 81
- Issue
- 10
- Pages
- 2636-2643
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2407998854
- Cited by
- 223
- References
- 8
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.