Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 297

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labeled annexin V

Open access
Kuypers, FA, Lewis, RA, Hua, M, Schott, MA, Discher, D, Ernst, JD, Lubin, BH · 1996 · Blood

Abstract

The phospholipids of the human red cell are distributed asymmetrically in the bilayer of the red cell membrane. In certain pathologic states, such as sickle cell anemia, phospholipid asymmetry is altered. Although several methods can be used to measure phospholipid organization, small organizational changes have been very difficult to assess. Moreover, these methods fail to identify subpopulations of cells that have lost their normal phospholipid asymmetry. Using fluorescently labeled annexin V in flow cytometry and fluorescent microscopy, we were able to identify and quantify red cells that had lost their phospholipid asymmetry in populations as small as 1 million cells. Moreover, loss of phospholipid organization in subpopulations as small as 0.1% of the total population could be identified, and individual cells could be studied by fluorescent microscopy. An excellent correlation was found between fluorescence-activated cell sorter (FACS) analysis results using annexin V to detect red cells with phosphatidylserine (PS) on their surface and a PS-requiring prothrombinase assay using similar red cells. Cells that bound fluorescein isothiocyanate (FITC)-labeled annexin V could be isolated from the population using magnetic beads covered with an anti-FITC antibody. Evaluation of blood samples from patients with sickle cell anemia under oxygenated conditions demonstrated the presence of subpopulations of cells that had lost phospholipid asymmetry. While only a few red cells were labeled in normal control samples (0.21% +/- 0.12%, n = 8), significantly increased (P < .001) annexin V labeling was observed in samples from patients with sickle cell anemia (2.18% +/- 1.21%, n = 13). We conclude that loss of phospholipid asymmetry may occur in small subpopulations of red cells and that fluorescently labeled annexin V can be used to quantify and isolate these cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v87.3.1179.bloodjournal8731179

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 297

Metadata

Authors
Kuypers, F., Lewis, R., Hua, M., Schott, M., Discher, D., Ernst, J., & Lubin, B.
Venue
Blood
Published
1996-02-01
Volume
87
Issue
3
Pages
1179-1187
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W105021832
Cited by
297
References
24
FWCI
8.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labeled annexin V. https://app.cochat.ai/papers/10.1182/blood.v87.3.1179.bloodjournal8731179
The paper
Kuypers, F., Lewis, R., Hua, M., Schott, M., Discher, D., Ernst, J., & Lubin, B. (1996). Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labeled annexin V. Blood. https://doi.org/10.1182/blood.v87.3.1179.bloodjournal8731179

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.