The DOI matches its Crossref record.
Annexin V for flow cytometric detection of phosphatidylserine expression on B cells undergoing apoptosis
Abstract
Apoptosis, or programmed cell death, is a general mechanism for removal of unwanted cells from the immune system. It is characterized by chromatin condensation, a reduction in cell volume, and endonuclease cleavage of DNA into oligonucleosomal length fragments. Apoptosis is also accompanied by a loss of membrane phospholipid asymmetry, resulting in the exposure of phosphatidylserine at the surface of the cell. Expression of phosphatidylserine at the cell surface plays an important role in the recognition and removal of apoptotic cells by macrophages. Here we describe a new method for the detection of apoptotic cells by flow cytometry, using the binding of fluorescein isothiocyanate-labeled annexin V to phosphatidylserine. When Burkitt lymphoma cell lines and freshly isolated germinal center B cells are cultured under apoptosis inducing conditions, all cells showing chromatin condensation strongly stain with annexin V, whereas normal cells are annexin V negative. Moreover, DNA fragmentation is only found in the annexin V-positive cells. The nonvital dye ethidium bromide was found to stain a subpopulation of the annexin V-positive apoptotic cells, increasing with time. Our results indicate that the phase in apoptosis that is characterized by chromatin condensation coincides with phosphatidylserine exposure. Importantly, it precedes membrane damage that might lead to release from the cells of enzymes that are harmful to the surrounding tissues. Annexin V may prove important in further unravelling the regulation of apoptosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Krasemann, S., Madore, C., Cialic, R., Baufeld, C., Calcagno, N., El Fatimy, R., Beckers, L., O’Loughlin, E., Xu, Y., Fanek, Z., et al. (2017) · Immunity · doi:10.1016/j.immuni.2017.08.008 · Cited by 2,979
Fadok, V. A., Bratton, D. L., Konowal, A., Freed, P. W., Westcott, J. Y., & Henson, P. M. (1998) · Journal of Clinical Investigation · doi:10.1172/jci1112 · Cited by 3,166
Martin, S. J., Reutelingsperger, C. P., McGahon, A. J., Rader, J. A., van Schie, R. C., LaFace, D. M., & Green, D. R. (1995) · The Journal of experimental medicine · doi:10.1084/jem.182.5.1545 · Cited by 2,824
Self-citationIdentification of a factor that links apoptotic cells to phagocytes
Hanayama, R., Tanaka, M., Miwa, K., Shinohara, A., Iwamatsu, A., & Nagata, S. (2002) · Nature · doi:10.1038/417182a · Cited by 1,401
Pathophysiologic Implications of Membrane Phospholipid Asymmetry in Blood Cells
Zwaal, R. F. A., & Schroit, A. J. (1997) · Blood · doi:10.1182/blood.v89.4.1121 · Cited by 1,340
Metadata
- Authors
- Koopman, G., Reutelingsperger, C., Kuijten, G., Keehnen, R., Pals, S., & van Oers, M.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1994-09-01
- Volume
- 84
- Issue
- 5
- Pages
- 1415-1420
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W125106425
- Cited by
- 2,681
- References
- 0
- FWCI
- 15.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Annexin V for flow cytometric detection of phosphatidylserine expression on B cells undergoing apoptosis. https://app.cochat.ai/papers/10.1182/blood.v84.5.1415.1415
- The paper
- Koopman, G., Reutelingsperger, C., Kuijten, G., Keehnen, R., Pals, S., & van Oers, M. (1994). Annexin V for flow cytometric detection of phosphatidylserine expression on B cells undergoing apoptosis. Blood. https://doi.org/10.1182/blood.v84.5.1415.1415
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.