Physiological changes during low- and high-intensity noninvasive ventilation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In a physiological randomised cross-over study performed in stable hypercapnic chronic obstructive disease patients, we assessed the short-term effects of two settings of noninvasive ventilation. One setting was aimed at maximally reducing arterial carbon dioxide tension (Pa,CO 2) (high-intensity (Hi) noninvasive positive pressure ventilation (NPPV)): mean±sd 27.6±2.1 cmH 2 O of inspiratory positive airway pressure, 4±0 cmH 2 O of expiratory positive airway pressure and respiratory rate of 22 breaths·min−1. The other was performed according to the usual parameters used in earlier studies (low-intensity (Li)-NPPV): 17.7±1.6 cmH 2 O of inspiratory positive airway pressure, 4±0 cmH 2 O of expiratory positive airway pressure and respiratory rate of 12 breaths·min−1. Both modes of ventilation significantly improved gas exchange compared with spontaneous breathing (SB), but to a greater extent using Hi-NPPV (Pa,CO 259.3±7.5, 55.2±6.9 and 49.4±7.8 mmHg for SB, Li-NPPV and Hi-NPPV, respectively). Similarly, Hi-NPPV induced a greater reduction in the pressure–time product of the diaphragm per minute from 323±149 cmH 2 O·s·min−1 during SB to 132±139 cmH 2 O·s·min−1 during Li-NPPV and 40±69 cmH 2 O·s·min−1 during Hi-NPPV, while in nine out of 15 patients, it completely abolished SB activity. Hi-NPPV also induced a marked reduction in cardiac output (CO) measured noninvasively with a Finometer PRO (Finapres Medical Systems BV, Amsterdam, the Netherlands) compared with Li-NPPV. We conclude that while Hi-NPPV is more effective than Li-NPPV in improving gas exchange and in reducing inspiratory effort, it induces a marked reduction in CO, which needs to be considered when Hi-NPPV is applied to patients with pre-existing cardiac disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Two-Period Change-Over Design and Its Use in Clinical Trials
Grizzle, J. E. (1965) · Biometrics · doi:10.2307/2528104 · Cited by 784 · cited 1×
“The protection test for carry-over effects was also performed [16, 17].”
Method
Cited by
Köhnlein, T., Windisch, W., Köhler, D., Drabik, A., Geiseler, J., Hartl, S., Karg, O., Laier-Groeneveld, G., Nava, S., Schönhofer, B., et al. (2014) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(14)70153-5 · Cited by 815
Self-citationErgan, B., Oczkowski, S., Rochwerg, B., Carlucci, A., Chatwin, M., Clini, E., Elliott, M., Gonzalez-Bermejo, J., Hart, N., Lujan, M., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01003-2019 · Cited by 306
Self-citationThe right interface for the right patient in noninvasive ventilation: a systematic review
Pierucci, P., Portacci, A., Carpagnano, G. E., Banfi, P., Crimi, C., Misseri, G., & Gregoretti, C. (2022) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2022.2121706 · Cited by 40
“by the patient but with higher levels of unintentional leakages [120,121].”
BackgroundSelf-citationEffects of skin surface temperature on photoplethysmograph
Jeong, I. C., Yoon, H., Kang, H., & Yeom, H. (2014) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.5.4.429 · Cited by 33
“Cardiovascular Parameter Sensors Finometer (Model-1, FMS, Netherlands) was used to continuously measure BP, HR, SV, CO and TPR while changing SST [10-14].”
Method
Metadata
- Authors
- Lukácsovits, J., Carlucci, A., Hill, N., Ceriana, P., Pisani, L., Schreiber, A., Pierucci, P., Losonczy, G., & Nava, S.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2011-09-01
- Volume
- 39
- Issue
- 4
- Pages
- 869-875
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2098620423
- Cited by
- 114
- References
- 1
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiological changes during low- and high-intensity noninvasive ventilation. https://app.cochat.ai/papers/10.1183/09031936.00056111
- The paper
- Lukácsovits, J., Carlucci, A., Hill, N., Ceriana, P., Pisani, L., Schreiber, A., Pierucci, P., Losonczy, G., & Nava, S. (2012). Physiological changes during low- and high-intensity noninvasive ventilation. European Respiratory Journal. https://doi.org/10.1183/09031936.00056111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.