Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 143

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Exercise ventilatory inefficiency in mild to end-stage COPD

Neder, J. Alberto, Arbex, Flavio F., Alencar, Maria Clara N., O’Donnell, Conor D.J., Cory, Julia, Webb, Kathy A., O’Donnell, Denis E.·2015·European Respiratory Journal

Abstract

Ventilatory inefficiency during exercise is a key pathophysiological feature of chronic obstructive pulmonary disease. Currently, it is unknown how this physiological marker relates to clinically relevant outcomes as resting ventilatory impairment progresses across disease stages. Slope and intercept of the linear region of the ventilation–carbon dioxide output relationship and the ratio between these variables, at the lowest point (nadir), were contrasted in 316 patients with Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages 1–4 (forced expiratory volume in 1 s, ranging from 148% pred to 12% pred) and 69 aged- and gender-matched controls, Compared to controls, slope and intercept were higher in GOLD stages 1 and 2, leading to higher nadirs (p<0.05). Despite even larger intercepts in GOLD stages 3 and 4, slopes diminished as disease evolved (from mean±sd 35±6 in GOLD stage 1 to 24±5 in GOLD stage 3, p<0.05). As a result, there were no significant differences in nadirs among patient groups. Higher intercepts, across all stages (p<0.01), and to a lesser extent lower slopes in GOLD stages 2–4 (p<0.05), were related to greater mechanical constraints, worsening pulmonary gas exchange, higher dyspnoea scores, and poorer exercise capacity. Increases in the ventilation intercept best indicate the progression of exercise ventilatory inefficiency across the whole spectrum of chronic obstructive pulmonary disease severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00135514

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 37

  1. Whipp, 1982, Cardiopulmonary coupling during exercise, J Exp Biol, 100, 175, 10.1242/jeb.100.1.175 · DOI
  2. Whipp BJ , Ward SA . The coupling of ventilation to pulmonary gas exchange during exercise. In: Whipp BJ, Wasserman K., eds. Pulmonary Physiology and Pathophysiology of Exercise. New York, Dekker, 1991:pp. 271–307.
  3. Wasserman K , Casaburi R . Acid-base regulation during exercise in humans. In: Whipp B.J. Wasserman K, eds. Pulmonary Physiology and Pathophysiology of Exercise. New York, Dekker, 1991; pp. 405–448.
  4. Whipp BJ . The control of exercise hyperpnea. In: Hornbein T, ed. The Regulation of Breathing. Dekker, New York, 1981; pp. 1069–1139.
  5. 10.1007/978-0-387-73693-8_3 · DOI
  6. 10.1164/arrd.1984.129.2P2.S17 · DOI
  7. 10.1164/rccm.201006-0965CI · DOI
  8. 10.1177/2047487313494293 · DOI
  9. 10.1016/j.resp.2011.07.013 · DOI
  10. 10.1016/j.resp.2012.12.013 · DOI
  11. 10.1164/rccm.201211-1970OC · DOI · Paper page
  12. 10.1016/j.hrtlng.2013.12.005 · DOI
  13. 10.1016/j.ahj.2010.07.014 · DOI
  14. 10.1159/000110207 · DOI · Paper page
  15. 10.1007/s00508-008-1103-5 · DOI
  16. Torchio, 2010, Exercise ventilatory inefficiency and mortality in patients with chronic obstructive pulmonary disease undergoing surgery for non-small cell lung cancer, Eur J Cardiothorac Surg, 38, 14919, 10.1016/j.ejcts.2010.01.032 · DOI
  17. Habedank D , Ewert R , Hummel M , et al. The effects of bilateral lung transplantation on ventilatory efficiency, oxygen uptake and the right heart: a two-yr follow-up. Clin Transplant 11;25: E38–E45. · DOI
  18. 10.1164/rccm.201203-0538OC · DOI
  19. 10.1016/j.ccm.2013.09.008 · DOI · Paper page
  20. 10.1164/rccm.2202033 · DOI
  21. 10.4187/respcare.01342 · DOI
  22. 10.1016/j.resp.2014.03.002 · DOI
  23. 10.4187/respcare.02629 · DOI
  24. 10.1371/journal.pone.0087395 · DOI
  25. 10.1164/ajrccm.164.8.2103007 · DOI
  26. 10.1249/00005768-198205000-00012 · DOI · Paper page
  27. Oren, 1981, Effect of CO2 set point on ventilatory response to exercise, J Appl Physiol Respir Environ Exerc Physiol, 51, 185
  28. 10.1016/j.resp.2011.08.009 · DOI
  29. Ward, 1980, Ventilatory control during exercise with increased external dead space, J Appl Physiol Respir Environ Exerc Physiol, 48, 225
  30. Poon, 1992, Potentiation of exercise ventilatory response by airway CO2 and dead space loading, J Appl Physiol, 73, 591, 10.1152/jappl.1992.73.2.591 · DOI
  31. 10.1164/rccm.201203-0404OC · DOI
  32. 10.1016/j.resp.2012.12.004 · DOI
  33. 10.1016/j.resp.2013.07.004 · DOI
  34. 10.1378/chest.106.5.1476 · DOI
  35. 10.1378/chest.92.5.832 · DOI
  36. 10.1007/s004210100422 · DOI
  37. Palange, 2000, Ventilatory and metabolic adaptations to walking and cycling in patients with COPD, J Appl Physiol, 88, 1715, 10.1152/jappl.2000.88.5.1715 · DOI

Cited by

See all 143

Metadata

Authors
Neder, J. A., Arbex, F. F., Alencar, M. C. N., O’Donnell, C. D. J., Cory, J., Webb, K. A., & O’Donnell, D. E.
Venue
European Respiratory Journal
Published
2014-10-30
Volume
45
Issue
2
Pages
377-387
ISSN
  • 0903-1936
  • 1399-3003
Cited by
143
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.