The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cardiopulmonary Exercise Test Characteristics in Patients with Chronic Obstructive Pulmonary Disease and Associated Pulmonary Hypertension
Abstract
Background: Pulmonary hypertension (PH) is a well-known complication of chronic obstructive pulmonary disease (COPD). It remains unclear whether exercise parameters can be used to discriminate between COPD patients with associated PH (COPD-PH) and COPD patients without associated PH (COPD-nonPH). Objective: To study whether the existence of pulmonary hypertension in COPD is related to characteristic findings in gas exchange and circulatory parameters during cardiopulmonary exercise testing (CPET). Methods: We retrospectively analyzed CPET data in 25 COPD patients in whom right heart catheterization had been performed. Differences were assessed between COPD-PH and COPD-nonPH patients in peak oxygen uptake (VO 2 peak), ventilatory efficiency (V E/V CO2), oxygen pulse, maximal ventilation and pulse oximetry (S pO2). Results: PH was found in 10 of 25 patients (mP pa = 33 ± 7 mm Hg), in 15 patients mean pulmonary artery pressure (mP pa) was below 25 mm Hg (18 ± 3 mm Hg). CPET in COPD-PH was characterized by a higher V E/V CO2 at nadir, a higher V E/V CO2 slope, and a lower S pO2 at rest and during exercise, but values in both groups were overlapping considerably. In the whole group mP pa was associated with resting P aO2 (r = –0.70, p < 0.001), V E/V CO2 nadir (r = 0.43, p < 0.05), and inversely related to S pO2 at rest and during exercise (r = –0.58 and r = –0.64, p < 0.01, respectively). Conclusion: Although CPET characteristics showed a large overlap in both groups, the existence of PH in COPD is associated with a significantly reduced ventilatory efficiency during CPET. However, a low S pO2 at rest and a further decrease during exercise similarly suggest the presence of PH in COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the absence of cardiac disease, cardiac output has been found to increase normally as a function of oxygen uptake during submaximal exercise in COPD, although stroke volume is generally smaller and heart rate correspondingly higher than in health [68,69].”
From Lung hyperinflation in COPD: applying physiology to clinical practice (2015) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Research works printed but not linked: 23
- 10.1056%2FNEJM197204272861703 · DOI
- 10.1159%2F000195950 · DOI
- 10.1164%2Frccm.2107027 · DOI
- 10.1378%2Fchest.127.5.1531 · DOI
- 10.1136%2Fthx.2005.042994 · DOI
- 10.1183%2F09031936.04.00118303 · DOI
- 10.1136%2Fthx.36.10.752 · DOI
- 10.1136%2Fthorax.57.12.1050 · DOI
- 10.1183%2F09031936.03.00115402 · DOI
- 10.1161%2Fhc2901.093198 · DOI
- 10.1016%2Fj.jacc.2004.02.032 · DOI · Paper page
- 10.1183%2F09031936.05.00034905 · DOI
- 10.1183%2F09031936.05.00035005 · DOI · Paper page
- 10.1164%2Frccm.2202033 · DOI
- 10.1378%2Fchest.94.5.931 · DOI
- 10.1159%2F000196647 · DOI
- 10.1378%2Fchest.102.4.1028 · DOI
- 10.1016%2Fj.jacc.2006.01.048 · DOI
- 10.1378%2Fchest.83.3.446 · DOI
- 10.1186%2Fcc1049 · DOI
- 10.1378%2Fchest.97.2.268 · DOI
- 10.1161%2F01.CIR.0000091409.53101.E8 · DOI
- 10.1164%2Frccm.200401-006OC · DOI
Cited by
2015 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension
Galiè, N., Humbert, M., Vachiery, J.-L., Gibbs, S., Lang, I., Torbicki, A., Simonneau, G., Peacock, A., Vonk Noordegraaf, A., Beghetti, M., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv317 · Cited by 6,931
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Guazzi, M., Adams, V., Conraads, V., Halle, M., Mezzani, A., Vanhees, L., Arena, R., Fletcher, G. F., Forman, D. E., Kitzman, D. W., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31826fb946 · Cited by 822
Lung hyperinflation in COPD: applying physiology to clinical practice
O’Donnell, D. E., Webb, K. A., & Neder, J. A. (2015) · COPD Research and Practice · doi:10.1186/s40749-015-0008-8 · Cited by 93
Shepherd, A. I., Wilkerson, D. P., Dobson, L., Kelly, J., Winyard, P. G., Jones, A. M., Benjamin, N., Shore, A. C., & Gilchrist, M. (2015) · Nitric Oxide · doi:10.1016/j.niox.2015.01.002 · Cited by 88
Metadata
- Authors
- Holverda, S., Bogaard, H. J., Groepenhoff, H., Postmus, P. E., Boonstra, A., & Vonk-Noordegraaf, A.
- Venue
- Respiration
- Publisher
- S. Karger AG
- Published
- 2007-10-25
- Volume
- 76
- Issue
- 2
- Pages
- 160-167
- ISSN
- 0025-7931
- 1423-0356
- Cited by
- 68
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiopulmonary Exercise Test Characteristics in Patients with Chronic Obstructive Pulmonary Disease and Associated Pulmonary Hypertension. https://app.cochat.ai/papers/10.1159/000110207
- The paper
- Holverda, S., Bogaard, H. J., Groepenhoff, H., Postmus, P. E., Boonstra, A., & Vonk-Noordegraaf, A. (2008). Cardiopulmonary Exercise Test Characteristics in Patients with Chronic Obstructive Pulmonary Disease and Associated Pulmonary Hypertension. Respiration. https://doi.org/10.1159/000110207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.