Effects of hyperinflation on the oxygen pulse as a marker of cardiac performance in COPD
Open accessAbstract
A decreased inspiratory capacity (IC)/total lung capacity (TLC) ratio is associated with dynamic hyperinflation and decreased exercise capacity. The present authors hypothesised that static (low IC/TLC) and dynamic hyperinflation impair cardiac function as assessed by oxygen pulse at rest and during cardiopulmonary exercise testing (CPET). Lung function, body mass index, hand grip strength and CPET parameters were measured (oxygen uptake (mL·kg−1·min−1) and oxygen pulse (mL·beat−1)) in 87 chronic obstructive pulmonary disease (COPD) patients (American Thoracic Society/European Respiratory Society/Global Initiative for Chronic Obstructive Lung Disease stage 3–4) and 46 controls. The patients were divided into those with IC/TLC >25% or ≤25%. The IC/TLC ratio at rest and at peak exercise was associated significantly with oxygen pulse. Patients with IC/TLC ≤25% (n = 45) had significantly lower exercise capacity, peak oxygen pulse, peak minus baseline oxygen pulse, peak IC, peak IC/TLC ratio and % change from baseline to peak IC/TLC ratio compared with patients with IC/TLC >25% and controls. During CPET, the oxygen pulse was lower at iso-work in patients with IC/TLC ≤25% than in those with IC/TLC >25%. Resting hyperinflation (inspiratory capacity/total lung capacity) is associated with lower oxygen pulse, peak exercise inspiratory capacity/total lung capacity and exercise capacity in patients with severe chronic obstructive pulmonary disease. The present results support an interaction between hyperinflation and decreased cardiac function that may contribute to exercise limitation in these patients.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Collectively, cardiovascular consequences of lung hyperinflation likely contribute, in highly variable combinations, to the reduced cardiac performance observed in some COPD patients during exercise.
“Collectively, these cardiovascular consequences of lung hyperinflation likely contribute, in highly variable combinations, to the reduced cardiac performance observed in some COPD patients during exercise.20,85”
From Pathogenesis of hyperinflation in chronic obstructive pulmonary disease (2014) · cites this paper as [85]
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627 · see citing works
O'Donnell, D. E., Voduc, N., Fitzpatrick, M., & Webb, K. A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00072703 · Cited by 365 · see citing works
Diaz, O., Villafranca, C., Ghezzo, H., Borzone, G., Leiva, A., Milic-Emil, J., & Lisboa, C. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16b14.x · Cited by 300 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Pathogenesis of hyperinflation in chronic obstructive pulmonary disease
Saey, Gagnon, P., Guenette, J., Langer, D., Laviolette, L., Mainguy, V., Maltais, F., & Ribeiro, F. (2014) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s38934 · Cited by 180 · see citing works
“20,85 However, it should be acknowledged that not all studies have been able to demonstrate a direct link between dynamic hyperinflation and cardiac performance during exercise.”
Ora, J., Laveneziana, P., Ofir, D., Deesomchok, A., Webb, K. A., & O'Donnell, D. E. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200904-0530oc · Cited by 139 · see citing works
Laveneziana, P., Palange, P., Ora, J., Martolini, D., & O’Donnell, D. E. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1169-4 · Cited by 60 · see citing works
- Authors
- Vassaux, C., Torre-Bouscoulet, L., Zeineldine, S., Cortopassi, F., Paz-Díaz, H., Celli, B. R., & Pinto-Plata, V. M.
- Affiliations
- Tufts University (US)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2008-06-11
- Volume
- 32
- Issue
- 5
- Pages
- 1275-1282
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2128487428
- Cited by
- 136
- References
- 3
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 5 · 2022: 2 · 2021: 2 · 2020: 7 · 2019: 9 · 2018: 9 · 2017: 6 · 2016: 7 · 2015: 14 · 2014: 6 · 2013: 17 · 2012: 12
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Keywords
- hyperinflation, chronic obstructive pulmonary disease, oxygen pulse, cardiac function, inspiratory capacity, total lung capacity, exercise capacity, cardiopulmonary exercise testing, exercise limitation
- MeSH terms
- Adult, Aged, Female, Forced Expiratory Volume, Humans, Lung, Male, Middle Aged, Oxygen, Respiratory Function Tests, Exercise, Body Mass Index, Multivariate Analysis, Case-Control Studies, Pulmonary Disease, Chronic Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review