The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Lung exposure to nanoparticles modulates an asthmatic response in a mouse model
Open accessAbstract
The aim of this study was to investigate the modulation of an asthmatic response by titanium dioxide (TiO 2) or gold (Au) nanoparticles (NPs) in a murine model of diisocyanate-induced asthma. On days 1 and 8, BALB/c mice received 0.3% toluene diisocyanate (TDI) or the vehicle acetone–olive oil (AOO) on the dorsum of both ears (20 μL). On day 14, the mice were oropharyngeally dosed with 40 μL of a NP suspension (0.4 mg·mL−1(∼0.8 mg·kg−1) TiO 2 or Au). 1 day later (day 15), the mice received an oropharyngeal challenge with 0.01% TDI (20 μL). On day 16, airway hyperreactivity (AHR), bronchoalveolar lavage (BAL) cell and cytokine analysis, lung histology, and total serum immunoglobulin E were assessed. NP exposure in sensitised mice led to a two- (TiO 2) or three-fold (Au) increase in AHR, and a three- (TiO 2) or five-fold (Au) increase in BAL total cell counts, mainly comprising neutrophils and macrophages. The NPs taken up by BAL macrophages were identified by energy dispersive X-ray spectroscopy. Histological analysis revealed increased oedema, epithelial damage and inflammation. In conclusion, these results show that a low, intrapulmonary doses of TiO 2 or Au NPs can aggravate pulmonary inflammation and AHR in a mouse model of diisocyanate-induced asthma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Size-dependent toxicity of metal oxide particles—A comparison between nano- and micrometer size
Karlsson, H. L., Gustafsson, J., Cronholm, P., & Möller, L. (2009) · Toxicology Letters · doi:10.1016/j.toxlet.2009.03.014 · Cited by 949
Hussain, S., Boland, S., Baeza-Squiban, A., Hamel, R., Thomassen, L. C. J., Martens, J. A., Billon-Galland, M. A., Fleury-Feith, J., Moisan, F., Pairon, J.-C., et al. (2009) · Toxicology · doi:10.1016/j.tox.2009.04.001 · Cited by 347
Self-citation
Cited by
Cancer therapy with iron oxide nanoparticles: Agents of thermal and immune therapies
Soetaert, F., Korangath, P., Serantes, D., Fiering, S., & Ivkov, R. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.06.025 · Cited by 406
Nanomaterials Versus Ambient Ultrafine Particles: An Opportunity to Exchange Toxicology Knowledge
Stone, V., Miller, M. R., Clift, M. J. D., Elder, A., Mills, N. L., Møller, P., Schins, R. P. F., Vogel, U., Kreyling, W. G., Alstrup Jensen, K., et al. (2017) · Environmental Health Perspectives · doi:10.1289/ehp424 · Cited by 370
Self-citationToxicity of Nano-Titanium Dioxide (TiO2-NP) Through Various Routes of Exposure: a Review
Shakeel, M., Jabeen, F., Shabbir, S., Asghar, M. S., Khan, M. S., & Chaudhry, A. S. (2016) · Biological Trace Element Research · doi:10.1007/s12011-015-0550-x · Cited by 320
Roulet, A., Armand, L., Dagouassat, M., Rogerieux, F., Simon-Deckers, A., Belade, E., Van Nhieu, J. T., Lanone, S., Pairon, J.-C., Lacroix, G., et al. (2012) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-12-38 · Cited by 21
Metadata
- Authors
- Hussain, S., Vanoirbeek, J. A. J., Luyts, K., De Vooght, V., Verbeken, E., Thomassen, L. C. J., Martens, J. A., Dinsdale, D., Boland, S., Marano, F., Nemery, B., & Hoet, P. H. M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2010-06-07
- Volume
- 37
- Issue
- 2
- Pages
- 299-309
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2160700027
- Cited by
- 160
- References
- 2
- FWCI
- 12.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung exposure to nanoparticles modulates an asthmatic response in a mouse model. https://app.cochat.ai/papers/10.1183/09031936.00168509
- The paper
- Hussain, S., Vanoirbeek, J. A. J., Luyts, K., De Vooght, V., Verbeken, E., Thomassen, L. C. J., Martens, J. A., Dinsdale, D., Boland, S., Marano, F., Nemery, B., & Hoet, P. H. M. (2011). Lung exposure to nanoparticles modulates an asthmatic response in a mouse model. European Respiratory Journal. https://doi.org/10.1183/09031936.00168509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.