Noninvasive monitoring of respiratory mechanics during sleep
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The sleep apnoea–hypopnoea syndrome is characterised by recurrent obstructions of the upper airway, resulting in sleep disruption and arterial oxygen desaturations. Noninvasive assessment of respiratory mechanics during sleep is helpful in facilitating the diagnosis and treatment of patients with sleep apnoea–hypopnoea syndrome. This series summarises the different tools that are currently available to noninvasively assess respiratory mechanics during sleep breathing disturbances. These techniques are classified according to the main variable monitored: ventilation, breathing effort or airway obstruction. Changes in patient ventilation are assessed by recording flow or volume signals by means of pneumotachographs, thermistors or thermocouples, nasal prongs or thoraco-abdominal bands. Common tools to noninvasively assess breathing efforts are the thoraco-abdominal bands and the pulse transit time technique. Upper airway obstruction is noninvasively characterised by its upstream resistance and its critical pressure or by means of the forced oscillation technique. Given the technical and practical limitations of each technique, combining different tools improves the reliability and robustness of patient assessment during sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathophysiology of obstructive sleep apnoea
Deegan, P., & McNicholas, W. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08071161 · Cited by 330
Respiratory monitoring using an air-mattress system
Chow, P., Nagendra, G., Abisheganaden, J., & Wang, Y. T. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/3/301 · Cited by 45
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Respiration rate and volume measurements using wearable strain sensors
Chu, M., Nguyen, T., Pandey, V., Zhou, Y., Pham, H. N., Bar-Yoseph, R., Radom-Aizik, S., Jain, R., Cooper, D. M., & Khine, M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0083-3 · Cited by 403
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography
Terrill, P. I., Edwards, B. A., Nemati, S., Butler, J. P., Owens, R. L., Eckert, D. J., White, D. P., Malhotra, A., Wellman, A., & Sands, S. A. (2015) · European Respiratory Journal · doi:10.1183/09031936.00062914 · Cited by 289
“Nasal pressure (square-root transformed) was taken as a surrogate of ventilatory flow [24], and was integrated (uncalibrated tidal volume × respiratory rate) and normalised by the mean to provide V E data for subsequent analysis.”
MethodSands, S. A., Edwards, B. A., Terrill, P. I., Taranto-Montemurro, L., Azarbarzin, A., Marques, M., Hess, L. B., White, D. P., & Wellman, A. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201707-1435oc · Cited by 291
“The nasal pressure signal was square-root transformed (9, 21, 22) to provide an uncalibrated surrogate of ventilatory flow that was then used to estimate the traits as described above.”
Method
Metadata
- Authors
- Farré, R., Montserrat, J. M., & Navajas, D.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-12
- Volume
- 24
- Issue
- 6
- Pages
- 1052-1060
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2071356443
- Cited by
- 107
- References
- 2
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive monitoring of respiratory mechanics during sleep. https://app.cochat.ai/papers/10.1183/09031936.04.00072304
- The paper
- Farré, R., Montserrat, J. M., & Navajas, D. (2004). Noninvasive monitoring of respiratory mechanics during sleep. European Respiratory Journal. https://doi.org/10.1183/09031936.04.00072304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.