Volatile organic compounds in the exhaled breath of young patients with cystic fibrosis
Open accessThe DOI matches its Crossref record.
Abstract
Inflammatory mediators in the exhaled breath are receiving growing medical interest as noninvasive disease markers. Volatile organic compounds have been investigated in this context, but clinical information and methodological standards are limited. The levels of ethane, propane,n-pentane, methanol, ethanol, 2-propanol, acetone, isoprene, benzene, toluene, dimethyl sulphide (DMS) and limonene were measured in repeated breath samples from 20 cystic fibrosis patients and 20 healthy controls (aged 8–29 yrs). Three end-exhaled and one ambient air sample were collected per person and analysed on a customised gas chromatography system. Intra-subject coefficients of variation ranged between 9 and 34%, and hydrocarbon breath levels were influenced by their inspired concentrations. The alveolar gradient for pentane was higher in cystic fibrosis patients than in healthy controls (0.36 versus 0.21 ppb) and inversely proportional to forced expiratory volume in one second; highest values were observed in patients with pulmonary exacerbations (0.73 versus 0.24 ppb). Cystic fibrosis patients also exhibited a lower output of DMS (3.9 versus 7.6 ppb). Group differences were not significant for ethane and the remaining substances. It was concluded that chemical breath analysis for volatile organic compounds is feasible and may hold potential for the noninvasive diagnosis and follow-up of inflammatory processes in cystic fibrosis lung disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Gut Microbiota Profiling: Metabolomics Based Approach to Unravel Compounds Affecting Human Health
Vernocchi, P., Del Chierico, F., & Putignani, L. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01144 · Cited by 426
The versatile use of exhaled volatile organic compounds in human health and disease
Boots, A. W., van Berkel, J. J. B. N., Dallinga, J. W., Smolinska, A., Wouters, E. F., & van Schooten, F. J. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027108 · Cited by 352
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Exhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Clinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review
van de Kant, K. D., van der Sande, L. J., Jöbsis, Q., van Schayck, O. C., & Dompeling, E. (2012) · Respiratory Research · doi:10.1186/1465-9921-13-117 · Cited by 252
Wilson, A. (2015) · Metabolites · doi:10.3390/metabo5010140 · Cited by 242
Current Challenges in Volatile Organic Compounds Analysis as Potential Biomarkers of Cancer
Schmidt, K., & Podmore, I. (2015) · Journal of Biomarkers · doi:10.1155/2015/981458 · Cited by 208
The Electronic Nose in Respiratory Medicine
Montuschi, P., Mores, N., Trové, A., Mondino, C., & Barnes, P. J. (2013) · Respiration · doi:10.1159/000340044 · Cited by 188
Metabolomics of Volatile Organic Compounds in Cystic Fibrosis Patients and Controls
Robroeks, C. M. H. H. T., van Berkel, J. J. B. N., Dallinga, J. W., Jöbsis, Q., Zimmermann, L. J. I., Hendriks, H. J. E., Wouters, M. F. M., van der Grinten, C. P. M., van de Kant, K. D. G., van Schooten, F.-J., et al. (2010) · Pediatric Research · doi:10.1203/pdr.0b013e3181df4ea0 · Cited by 179
“(21) studied 12 specific VOCs by means of a customized GC in CF patients and controls.”
BackgroundA Novel Breath Analysis System Based on Electronic Olfaction
Guo, D., Zhang, D., Li, N., Zhang, L., & Yang, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055864 · Cited by 178
Barucha, A., Mauch, R. M., Duckstein, F., Zagoya, C., & Mainz, J. G. (2022) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2022.2104249 · Cited by 6
“The authors propose serial measurements before and after antibiotic treatment to gather more evidence for the usefulness of n-pentane analysis [23].”
BackgroundMethodInfluential
Metadata
- Authors
- Barker, M., Hengst, M., Schmid, J., Buers, H.-J., Mittermaier, B., Klemp, D., & Koppmann, R.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2006-02-02
- Volume
- 27
- Issue
- 5
- Pages
- 929-936
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2170149258
- Cited by
- 181
- References
- 0
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.