A respiratory gas exchange simulator for routine calibration in metabolic studies
Open accessThe DOI matches its Crossref record.
Abstract
We have developed a method for simulating respiratory gas exchange for on-line calibration of metabolic measurement systems. It utilizes a pump which intakes a mixture of atmospheric air and a known flow of precision-analysed calibration gas (21% CO2, 79% N2). It expels the resulting mixture with flow wave form and profiles of gas concentration which closely resemble those of normal expiration. Control of the calibration mixture's inflow allows the investigator to set any desired metabolic rate regardless of the minute ventilatory rate. This separation of metabolic from ventilatory rates provides a stringent test of the computational performance of the respiratory gas exchange measurement systems. The apparatus can reproduce any range of respiratory and metabolic performance (currently ranging from 0.2-5 l.min-1 O2 uptake and CO2 output) with accuracy +/- 2%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Levett, D. Z. H., Jack, S., Swart, M., Carlisle, J., Wilson, J., Snowden, C., Riley, M., Danjoux, G., Ward, S. A., Older, P., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.020 · Cited by 466
Casaburi, R., Porszasz, J., Burns, M. R., Carithers, E. R., Chang, R. S., & Cooper, C. B. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154855 · Cited by 445
Metadata
- Authors
- Huszczuk, A., Whipp, B., & Wasserman, K.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1990-04-01
- Volume
- 3
- Issue
- 4
- Pages
- 465-468
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2147375204
- Cited by
- 119
- References
- 0
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A respiratory gas exchange simulator for routine calibration in metabolic studies. https://app.cochat.ai/papers/10.1183/09031936.93.03040465
- The paper
- Huszczuk, A., Whipp, B., & Wasserman, K. (1990). A respiratory gas exchange simulator for routine calibration in metabolic studies. European Respiratory Journal. https://doi.org/10.1183/09031936.93.03040465
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.