A respiratory gas exchange simulator for routine calibration in metabolic studies
Open accessThe DOI matches its Crossref record.
Abstract
We have developed a method for simulating respiratory gas exchange for on-line calibration of metabolic measurement systems. It utilizes a pump which intakes a mixture of atmospheric air and a known flow of precision-analysed calibration gas (21% CO2, 79% N2). It expels the resulting mixture with flow wave form and profiles of gas concentration which closely resemble those of normal expiration. Control of the calibration mixture's inflow allows the investigator to set any desired metabolic rate regardless of the minute ventilatory rate. This separation of metabolic from ventilatory rates provides a stringent test of the computational performance of the respiratory gas exchange measurement systems. The apparatus can reproduce any range of respiratory and metabolic performance (currently ranging from 0.2-5 l.min-1 O2 uptake and CO2 output) with accuracy +/- 2%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Levett, D. Z. H., Jack, S., Swart, M., Carlisle, J., Wilson, J., Snowden, C., Riley, M., Danjoux, G., Ward, S. A., Older, P., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.020 · Cited by 466
Casaburi, R., Porszasz, J., Burns, M. R., Carithers, E. R., Chang, R. S., & Cooper, C. B. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154855 · Cited by 445
Emtner, M., Porszasz, J., Burns, M., Somfay, A., & Casaburi, R. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200212-1525oc · Cited by 352
ERS statement on standardisation of cardiopulmonary exercise testing in chronic lung diseases
Radtke, T., Crook, S., Kaltsakas, G., Louvaris, Z., Berton, D., Urquhart, D. S., Kampouras, A., Rabinovich, R. A., Verges, S., Kontopidis, D., et al. (2019) · European Respiratory Review · doi:10.1183/16000617.0101-2018 · Cited by 338
O'Donovan, G., Owen, A., Bird, S. R., Kearney, E. M., Nevill, A. M., Jones, D. W., & Woolf-May, K. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01310.2004 · Cited by 276
Prediction of metabolic and cardiopulmonary responses to maximum cycle ergometry: a randomised study
Neder, J., Nery, L., Castelo, A., Andreoni, S., Lerario, M., Sachs, A., Silva, A., & Whipp, B. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.14613049 · Cited by 226
“For example, although a metabolic calibrator was used to validate the ventilatory and gas exchange measurements [27], the "true" standard criterion was not used (timed expired gas collection).”
BackgroundMethodSelf-citationEffects of hypoxic hypoxia on O2uptake and heart rate kinetics during heavy exercise
Engelen, M., Porszasz, J., Riley, M., Wasserman, K., Maehara, K., & Barstow, T. J. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2500 · Cited by 207
Self-citationScheuermann, B. W., Hoelting, B. D., Noble, M. L., & Barstow, T. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0245j.x · Cited by 182
“Pulmonary gas exchange (VO2 and VCO2) and minute expired ventilation (VE) were measured breath by breath using a metabolic measurement system (MedGraphics Cardio2, Medical Graphics Corp., St Pauls, MN, USA).”
MethodSietsema, K. E., Ben-Dov, I., Yu Zhang, Y., Sullivan, C., & Wasserman, K. (1994) · Chest · doi:10.1378/chest.105.6.1693 · Cited by 173
Self-citationValidity, reliability and stability of the portable Cortex Metamax 3B gas analysis system
Macfarlane, D. J., & Wong, P. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2230-7 · Cited by 167
“The GESV (MedGraphics, MA, USA; a similar, but updated, GESV is now sold by Vacumed, CA, USA) was a mechanical gas exchange system simulating human breathing and has a reported accuracy in producing VO2 and VCO2 of ±2% (Huszczuk et al. 1990).”
BackgroundO'Donovan, G., Owen, A., Kearney, E. M., Jones, D. W., Nevill, A. M., Woolf-May, K., & Bird, S. R. (2005) · International Journal of Obesity · doi:10.1038/sj.ijo.0803004 · Cited by 61
Metadata
- Authors
- Huszczuk, A., Whipp, B., & Wasserman, K.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1990-04-01
- Volume
- 3
- Issue
- 4
- Pages
- 465-468
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2147375204
- Cited by
- 119
- References
- 0
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.