CoChat

Force-frequency relationships of in vivo human and in vitro rat diaphragm using paired stimuli

Open access
Yan, S, Gauthier, AP, Similowski, T, Faltus, R, Macklem, PT, Bellemare, F · 1993 · European Respiratory Journal
Cited by 39

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Supramaximal stimuli, with time intervals of 100 ms (10 Hz) to 10 ms (100 Hz), were delivered in pairs to the phrenic nerves, bilaterally, in five seated normal subjects, while transdiaphragmatic pressure swings (Pdi,s) were recorded at relaxed end-expiratory lung volume with airways closed. In fresh diaphragms, Pdi,s increased between 10-20 Hz and reached a plateau between 20-30 Hz. Diaphragmatic fatigue decreased Pdi,s at all frequencies. Pdi,s was assumed to be the sum of two successive responses (T1+T2), T1 being constant at any frequency and equal to a single twitch, T2 being obtained by subtraction. We found that T2 amplitude, which was significantly reduced after fatigue, was fully returned to normal after 15 min rest at high, not at low, stimulation frequencies. The ratio of T2 at 10 Hz over 100 Hz (T2(10/100)) thus decreased from 1.33 +/- 0.05 before fatigue to 0.97 +/- 0.12 after fatigue, and to 0.81 +/- 0.06 after 15 min rest. Similar results were obtained in isolated rat diaphragmatic strips stimulated and fatigued in vitro, from which we found a highly linear relationship (r = 0.94, p < 0.001) between the ratio of T2(10/100) and that of tetanic force at 10 Hz over 100 Hz (P10/100). We conclude that phrenic nerve paired twitches provide similar information when obtained from phrenic tetanic stimulation in terms of diaphragmatic contractility, and the decrease in T2(10/100) ratio indicates diaphragm low frequency fatigue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.93.06020211

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 39

Metadata

Authors
Yan, S., Gauthier, A., Similowski, T., Faltus, R., Macklem, P., & Bellemare, F.
Venue
European Respiratory Journal
Published
1993-02-01
Volume
6
Issue
2
Pages
211-218
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W1957461011
Cited by
39
References
2
FWCI
0.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Force-frequency relationships of in vivo human and in vitro rat diaphragm using paired stimuli. https://app.cochat.ai/papers/10.1183/09031936.93.06020211
The paper
Yan, S., Gauthier, A., Similowski, T., Faltus, R., Macklem, P., & Bellemare, F. (1993). Force-frequency relationships of in vivo human and in vitro rat diaphragm using paired stimuli. European Respiratory Journal. https://doi.org/10.1183/09031936.93.06020211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.