The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea
Open accessAbstract
Pulse transit time (PTT) is the time taken for the arterial pulse pressure wave to travel from the aortic valve to a peripheral site. For convenience, it is usually measured from the R wave on the electrocardiogram to the pulse wave arrival at the finger. Pulse transit time is inversely proportional to blood pressure, and the falls in blood pressure which occur with inspiration (pulsus paradoxus) correspond to rises (lengthening) in pulse transit time. In awake normal subjects, the size of these inspiratory rises in pulse transit time correlate well with the degree of inspiratory effort. The aim of this study was to investigate whether inspiratory rises in pulse transit time could provide a quantitative measure of inspiratory effort in patients with obstructive sleep apnoea. Eight patients with obstructive sleep apnoea, attending the laboratory for institution of nasal continuous positive airway pressure, took part in the study. Once asleep, airway pressure was varied between optimal treatment level and minimum pressure, to produce a range of inspiratory efforts whilst continuous recordings of oesophageal pressure and pulse transit time were made. There was an excellent correlation between the size of the swings in oesophageal pressure and the size of the swings in pulse transit time (mean r = 0.94). Pulse transit time may, therefore, provide a clinically useful noninvasive and quantitative measure of inspiratory effort in patients with sleep-related breathing disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
The Visual Scoring of Sleep and Arousal in Infants and Children
Grigg-Damberger, M., Gozal, D., Marcus, C. L., Quan, S. F., Rosen, C. L., Chervin, R. D., Wise, M., Picchietti, D. L., Sheldon, S. H., & Iber, C. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26819 · Cited by 361
The upper airway in sleep: physiology of the pharynx
Ayappa, I., & Rapoport, D. M. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0238 · Cited by 340
Pulse transit time: an appraisal of potential clinical applications
Smith, R. P., Argod, J., Pepin, J.-L., & Levy, P. A. (1999) · Thorax · doi:10.1136/thx.54.5.452 · Cited by 317
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Metadata
- Authors
- Pitson, D., Sandell, A., van den Hout, R., & Stradling
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1995-10-01
- Volume
- 8
- Issue
- 10
- Pages
- 1669-1674
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2126129915
- Cited by
- 164
- References
- 1
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. https://app.cochat.ai/papers/10.1183/09031936.95.08101669
- The paper
- Pitson, D., Sandell, A., van den Hout, R., & Stradling. (1995). Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. European Respiratory Journal. https://doi.org/10.1183/09031936.95.08101669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.