CoChat

Videomicroscopy of methacholine-induced contraction of individual airways in precision-cut lung slices

Open access
Martin, C, Uhlig, S, Ullrich, V · 1996 · European Respiratory Journal
Cited by 171

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Contraction of airways of different size can be studied in viable lung slices by videomicroscopy. However, at present, application of this technique is limited by the heterogeneous responses obtained. We investigated the use of precision-cut lung slices to examine contraction of individual airways. Lung slices of 250 +/- 20 microns were prepared from Wistar rats and cultured in a roller incubator in serum-free minimum essential medium (MEM). Under these conditions, the slices were viable for at least 70 h, as indicated by leakage of lactate dehydrogenase into the supernatant, thymidine incorporation and ciliary beating. The slices were placed in a newly developed incubation chamber and mounted by a nylon thread that was fixed to a platinum wire. The whole chamber was positioned on a microscope stage, and contraction of single airways was followed under a microscope that was coupled to a CCD-camera. Reduction in airway area was taken as an index of bronchoconstriction and was determined by a computer program. Addition of methacholine resulted in a concentration-dependent (concentration producing half the maximal effect (EC50) = 0.64 +/- 0.08 (mean +/- SD) microM; n = 64) contraction of single airways. In the presence of hydrocortisone, the EC50 was about six times greater, i.e. 3.7 +/- 0.9 microM (n = 7), and the effect of the steroid was largely abolished by propanolol (EC50 = 1.1 +/- 0.1 microM; n = 7). Airways with an area smaller than 35,000 microns2 were nearly nine times more sensitive to methacholine (EC50 = 0.1 +/- 0.03 microM; n = 20) than larger ones (EC50 = 87 +/- 0.27 microM; n = 22). We conclude that cultured precision-cut lung slices are a useful model for routine study of contraction of individual airways of various sizes. The measurements were precise and reproducible and showed that smaller airways are more sensitive to methacholine than larger ones.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.96.09122479

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Martin, C., Uhlig, S., & Ullrich, V
Venue
European Respiratory Journal
Published
1996-12-01
Volume
9
Issue
12
Pages
2479-2487
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2122669560
Cited by
171
References
10
FWCI
0.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.