We have previously shown that AutoSet satisfactorily improves sleep-disordered breathing and sleep architecture in subjects with obstructive sleep apnoea (OSA) syndrome. The aim of this study was to determine, in subjects treated with long-term conventional fixed pressure continuous positive airway pressure (CPAP) at the AutoSet recommended pressure, whether: the long-term compliance is satisfactory; the improvement persists once initial rebound is over; the titration pressure is stable with time; and the titration pressure is comparable with manual titration pressure using a similar end-point. Twenty males with OSA, previously studied with full polysomnography on their diagnostic night, at manual and AutoSet titration, and at the AutoSet recommended fixed pressure, were re-studied after a mean of 3 and 8 months of treatment at the recommended fixed pressure. Re-study included home respiratory monitoring (Nellcor EdenTrace), and repeated manual and AutoSet titration with polysomnography. Compliance was assessed with hour-meter readings. Mean (+/-SEM) usage was 5.7 +/- 0.1 h.night-1 at 3 and 8 months. The arousal index remained normalized. Diagnostic respiratory disturbance index (RDI) was 60.3 +/- 5.7 events.h-1. On AutoSet at fixed CPAP, RDI was initially 2.6 +/- 0.7 events.h-1, then rose slightly (p < 0.001) to 4.3 +/- 0.6 events.h-1 at 3 months, and was 3.6 +/- 0.5 events.h-1 at 8 months. AutoSet titration pressure was: 9.9 +/- 0.4 cmH2O initially, 10.6 +/- 0.4 cmH2O at 3 months, and 9.7 +/- 0.5 cmH2O at 8 months (NS). Manual titration pressure at 8 months was 10.4 +/- 0.4 cmH2O. The standard deviation of the discrepancy with AutoSet was 0.84 cmH2O. In conclusion, the AutoSet recommended pressure varies little with time, and closely predicts the final manual titration pressure; the improvement in respiratory disturbance index was largely maintained, and compliance was good, although probably enhanced by close supervision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.97.10092073

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 77

Metadata

Authors
Teschler, H., Farhat, A., Exner, V, Konietzko, N., & Berthon-Jones, M.
Venue
European Respiratory Journal
Published
1997-09-01
Volume
10
Issue
9
Pages
2073-2078
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2166611413
Cited by
77
References
4
FWCI
4.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AutoSet nasal CPAP titration: constancy of pressure, compliance and effectiveness at 8 month follow-up. https://app.cochat.ai/papers/10.1183/09031936.97.10092073
The paper
Teschler, H., Farhat, A., Exner, V, Konietzko, N., & Berthon-Jones, M. (1997). AutoSet nasal CPAP titration: constancy of pressure, compliance and effectiveness at 8 month follow-up. European Respiratory Journal. https://doi.org/10.1183/09031936.97.10092073

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.