The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'th): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th. V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow, V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.98.11010179

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 137

Metadata

Authors
Farre, R., Montserrat, J., Rotger, M., Ballester, E., & Navajas, D.
Venue
European Respiratory Journal
Published
1998-01-01
Volume
11
Issue
1
Pages
179-182
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2113944799
Cited by
137
References
0
FWCI
3.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas. https://app.cochat.ai/papers/10.1183/09031936.98.11010179
The paper
Farre, R., Montserrat, J., Rotger, M., Ballester, E., & Navajas, D. (1998). Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas. European Respiratory Journal. https://doi.org/10.1183/09031936.98.11010179

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.