Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas
Open accessThe DOI matches its Crossref record.
Abstract
The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'th): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th. V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow, V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Obstructive sleep apnoea in the general population: highly prevalent but minimal symptoms
Arnardottir, E. S., Bjornsdottir, E., Olafsdottir, K. A., Benediktsdottir, B., & Gislason, T. (2016) · European Respiratory Journal · doi:10.1183/13993003.01148-2015 · Cited by 261
Tidal breath analysis for infant pulmonary function testing
Bates, J. H. T., Schmalisch, G., Filbrun, D., Stocks, J., & on behalf of theErs/ats Task Force on Standards for Infant Respiratory Function Testing (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16f26.x · Cited by 241
“Attention is restricted to this device in the present document, although several new devices, such as ultrasonic flowmeters and hot wire anemometers [17], are currently being developed and validated for use in infant respiratory function measurements.”
BackgroundStradling, J. R. (2004) · Thorax · doi:10.1136/thx.2003.007161 · Cited by 221
Randomised trial of nasal surgery for fixed nasal obstruction in obstructive sleep apnoea
Koutsourelakis, I., Georgoulopoulos, G., Perraki, E., Vagiakis, E., Roussos, C., & Zakynthinos, S. G. (2008) · European Respiratory Journal · doi:10.1183/09031936.00087607 · Cited by 131
“Although these devices are nonobtrusive and easily tolerated, they cannot quantify ventilation, partly because their signal–flow relationship is nonlinear, resulting in underestimation of nasal ventilation and overestimation of oral ventilation, especially at low flows [ 29 , 30].”
BackgroundObstructive sleep apnoea and oral breathing in patients free of nasal obstruction
Koutsourelakis, I., Vagiakis, E., Roussos, C., & Zakynthinos, S. (2006) · European Respiratory Journal · doi:10.1183/09031936.00058406 · Cited by 87
“However, the flow signal they provide is not a direct measure of actual flow [ 14 ] and thus, the detection of airflow provides only qualitative information [15].”
BackgroundCalibration Model for Apnea-Hypopnea Indices: Impact of Alternative Criteria for Hypopneas
Ho, V., Crainiceanu, C. M., Punjabi, N. M., Redline, S., & Gottlieb, D. J. (2015) · Sleep · doi:10.5665/sleep.5234 · Cited by 87
Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
Nakano, H., Tanigawa, T., Ohnishi, Y., Uemori, H., Senzaki, K., Furukawa, T., & Nishima, S. (2008) · European Respiratory Journal · doi:10.1183/09031936.00130907 · Cited by 43
Metadata
- Authors
- Farre, R., Montserrat, J., Rotger, M., Ballester, E., & Navajas, D.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1998-01-01
- Volume
- 11
- Issue
- 1
- Pages
- 179-182
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2113944799
- Cited by
- 137
- References
- 0
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.