Standardisation and application of the single-breath determination of nitric oxide uptake in the lung
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Diffusing capacity of the lung for nitric oxide (DLNO), otherwise known as the transfer factor, was first measured in 1983. This document standardises the technique and application of single-breath DLNO. This panel agrees that 1) pulmonary function systems should allow for mixing and measurement of both nitric oxide (NO) and carbon monoxide (CO) gases directly from an inspiratory reservoir just before use, with expired concentrations measured from an alveolar “collection” or continuously sampled via rapid gas analysers; 2) breath-hold time should be 10 s with chemiluminescence NO analysers, or 4–6 s to accommodate the smaller detection range of the NO electrochemical cell; 3) inspired NO and oxygen concentrations should be 40–60 ppm and close to 21%, respectively; 4) the alveolar oxygen tension (PAO 2) should be measured by sampling the expired gas; 5) a finite specific conductance in the blood for NO (θNO) should be assumed as 4.5 mL·min-1·mmHg-1·mL-1 of blood; 6) the equation for 1/θCO should be (0.0062·PAO 2+1.16)·(ideal haemoglobin/measured haemoglobin) based on breath-holding PAO 2and adjusted to an average haemoglobin concentration (male 14.6 g·dL−1, female 13.4 g·dL−1); 7) a membrane diffusing capacity ratio (DMNO/DMCO) should be 1.97, based on tissue diffusivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
(1993) · PubMed · Cited by 3,827
Standardisation of the single-breath determination of carbon monoxide uptake in the lung
MacIntyre, N., Crapo, R. O., Viegi, G., Johnson, D. C., van der Grinten, C. P. M., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034905 · Cited by 2,255
General considerations for lung function testing
Miller, M. R., Crapo, R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., Grinten, C. P. M. V. D., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034505 · Cited by 2,026
Low-pressure solubility of gases in liquid water
Wilhelm, E., Battino, R., & Wilcock, R. J. (1977) · Chemical Reviews · doi:10.1021/cr60306a003 · Cited by 1,807
Roughton, F. J. W., & Forster, R. E. (1957) · Journal of Applied Physiology · doi:10.1152/jappl.1957.11.2.290 · Cited by 999
2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung
Graham, B. L., Brusasco, V., Burgos, F., Cooper, B. G., Jensen, R., Kendrick, A., MacIntyre, N. R., Thompson, B. R., & Wanger, J. (2017) · European Respiratory Journal · doi:10.1183/13993003.00016-2016 · Cited by 972
Standardization of the measurement of transfer factor (diffusing capacity)
Cotes, J. E., Chinn, D. J., Quanjer, P. H., Roca, J., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.041s1693 · Cited by 680
The diffusion of gases through the lungs of man
Krogh, M. (1915) · The Journal of Physiology · doi:10.1113/jphysiol.1915.sp001710 · Cited by 432
The kinetics and equilibria of the reactions of nitric oxide with sheep haemoglobin
Gibson, Q. H., & Roughton, F. J. W. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005777 · Cited by 395
Hughes, J. M. B., & Pride, N. B. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201112-2160ci · Cited by 259
Self-citationJones, R. S., & Meade, F. (1961) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1961.sp001525 · Cited by 233
Erythrocytes Possess an Intrinsic Barrier to Nitric Oxide Consumption
Vaughn, M. W., Huang, K.-T., Kuo, L., & Liao, J. C. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.4.2342 · Cited by 225
Borland, C., & Higenbottam, T. (1989) · European Respiratory Journal · doi:10.1183/09031936.93.02010056 · Cited by 222
Self-citationGuenard, H., Varene, N., & Vaida, P. (1987) · Respiration Physiology · doi:10.1016/s0034-5687(87)80036-1 · Cited by 214
Mechanism of chemiluminescent reaction between nitric oxide and ozone
Clough, P. N., & Thrush, B. A. (1967) · Transactions of the Faraday Society · doi:10.1039/tf9676300915 · Cited by 201
Carlsen, E., & Comroe, J. H. (1958) · The Journal of General Physiology · doi:10.1085/jgp.42.1.83 · Cited by 175
Clutton-Brock, J. (1967) · British Journal of Anaesthesia · doi:10.1093/bja/39.5.388 · Cited by 154
Measurement of exhaled nitric oxide in man.
Borland, C. D. R., Cox, Y., & Higenbottam, T. (1993) · Thorax · doi:10.1136/thx.48.11.1160 · Cited by 152
Self-citationRecruitment of Lung Diffusing Capacity
Hsia, C. C. W. (2002) · CHEST Journal · doi:10.1378/chest.122.5.1774 · Cited by 150
Self-citationTamhane, R. M., Johnson, R. L., & Hsia, C. C. W. (2001) · CHEST Journal · doi:10.1378/chest.120.6.1850 · Cited by 134
Self-citationEuropean reference equations for CO and NO lung transfer
Aguilaniu, B., Maitre, J., Glénet, S. N., Gégout‐Petit, A., & Guénard, H. J.-P. (2008) · European Respiratory Journal · doi:10.1183/09031936.00063207 · Cited by 128
Self-citationDiminished Alveolar Microvascular Reserves in Type 2 Diabetes Reflect Systemic Microangiopathy
Chance, W. W., Rhee, C., Yılmaz, C., Dane, D. M., Pruneda, M. L., Raskin, P., & Hsia, C. C. W. (2008) · Diabetes Care · doi:10.2337/dc07-2323 · Cited by 127
Self-citationHughes, J. M. B., & Bates, D. V. (2003) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2003.08.004 · Cited by 117
Self-citationDiffusion of Gases Across the Alveolar Membrane
Forster, R. E. (1987) · Comprehensive physiology · doi:10.1002/cphy.cp030405 · Cited by 100
Exercise Pathophysiology in Patients With Chronic Mountain Sickness
Groepenhoff, H., Overbeek, M. J., Mulè, M., van der Plas, M. N., Argiento, P., Villafuerte, F. C., Beloka, S., Faoro, V., Macarlupú, J. L., Guénard, H. J.-P., et al. (2012) · CHEST Journal · doi:10.1378/chest.11-2845 · Cited by 89
Self-citationSignificant blood resistance to nitric oxide transfer in the lung
Borland, C. D. R., Dunningham, H., Bottrill, F. E., Vuylsteke, A., Yılmaz, C., Dane, D. M., & Hsia, C. C. W. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00904.2009 · Cited by 80
Self-citationReference values of pulmonary diffusing capacity for nitric oxide in an adult population
Zavorsky, G. S., Cao, J., & Murias, J. M. (2007) · Nitric Oxide · doi:10.1016/j.niox.2007.10.002 · Cited by 74
Self-citationZavorsky, G. S., Quiron, K. B., Massarelli, P. S., & Lands, L. C. (2004) · CHEST Journal · doi:10.1378/chest.125.3.1019 · Cited by 74
Self-citationNitric Oxide Diffusing Capacity and Alveolar Microvascular Recruitment in Sarcoidosis
Phansalkar, A. R., Hanson, C. M., Shakir, A. R., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1287oc · Cited by 71
Diffusing capacity for nitric oxide: Reference values and dependence on alveolar volume
van der Lee, I., Zanen, P., Stigter, N., et al. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2006.12.001 · Cited by 67
Farha, S., Laskowski, D. M., George, D., Park, M. M., Tang, W. H. W., Dweik, R. A., & ERZURUM, S. C. (2013) · Respiratory Research · doi:10.1186/1465-9921-14-6 · Cited by 66
Rate at which CO replaces O2 from O2Hb in red cells of different species
Holland, R. A. B. (1969) · Respiration Physiology · doi:10.1016/0034-5687(69)90068-1 · Cited by 63
Mechanisms of Slower Nitric Oxide Uptake by Red Blood Cells and Other Hemoglobin-containing Vesicles
Azarov, I., Liu, C., Reynolds, H., Tsekouras, Z., Lee, J. S., Gladwin, M. T., & Kim‐Shapiro, D. B. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.228650 · Cited by 59
Effects of gravity on lung diffusing capacity and cardiac output in prone and supine humans
Rohdin, M., Petersson, J., Sundblad, P., Mure, M., Glenny, R. W., Lindahl, S. G. E., & Linnarsson, D. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01154.2002 · Cited by 57
Deciphering the nitric oxide to carbon monoxide lung transfer ratio: physiological implications
Glénet, S. N., de Bisschop, C., Vargas, F., & Guénard, H. J.-P. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.133405 · Cited by 56
Self-citationPulmonary circulation and gas exchange at exercise in Sherpas at high altitude
Faoro, V., Huez, S., Vanderpool, R. R., Groepenhoff, H., de Bisschop, C., Martinot, J., Lamotte, M., Pavelescu, A., Guénard, H. J.-P., & Naeije, R. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00236.2013 · Cited by 56
Self-citationA Novel Approach to Partition Central and Peripheral Airway Nitric Oxide
Paredi, P., Kharitonov, S. A., Meah, S., Barnes, P. J., & Usmani, O. S. (2013) · CHEST Journal · doi:10.1378/chest.13-0843 · Cited by 55
Correction of Single-Breath Helium Lung Volumes in Patients With Airflow Obstruction
Punjabi, N. M., Shade, D. M., & Wise, R. A. (1998) · CHEST Journal · doi:10.1378/chest.114.3.907 · Cited by 53
Sources of Long-term Variability in Measurements of Lung Function
Jensen, R. L., Teeter, J. G., England, R. D., Howell, H. M., White, H. J., Pickering, E. H., & Crapo, R. O. (2007) · CHEST Journal · doi:10.1378/chest.06-1999 · Cited by 51
Diurnal Variation of the Diffusing Capacity of the Lung: Is it Real?
Frey, T. M., Crapo, R. O., Jensen, R. L., & Elliott, C. G. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.6.1381 · Cited by 51
Nitric oxide and carbon monoxide lung transfer in patients with advanced liver cirrhosis
Degano, B., Mittaine, M., Guénard, H. J.-P., RAMI, J., Garcia, G., Kamar, N., Bureau, C., Péron, J., Rostaing, L. P. E., & Rivière, D. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91621.2008 · Cited by 45
Self-citationDiurnal variation in pulmonary diffusing capacity for carbon monoxide.
Cinkotai, F. F., & Thomson, M. L. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.2.539 · Cited by 43
A Theoretical Analysis of the Single Breath Diffusing Capacity for Carbon Monoxide
Graham, B. L., Dosman, J. A., & Cotton, D. J. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326726 · Cited by 41
Nitric oxide diffusing capacity versus spirometry in the early diagnosis of emphysema in smokers
van der Lee, I., Gietema, H. A., Zanen, P., et al. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.06.005 · Cited by 40
The Single-Breath Diffusing Capacity of CO and NO in Healthy Children of European Descent
Thomas, A., Hanel, B., Marott, J. L., Buchvald, F. F., Mortensen, J., & Nielsen, K. G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0113177 · Cited by 39
Alveolar-Membrane Diffusing Capacity Improves in the Morbidly Obese after Bariatric Surgery
Zavorsky, G. S., Kim, D. J., Sylvestre, J.-L., & Christou, N. V. (2008) · Obesity Surgery · doi:10.1007/s11695-007-9294-9 · Cited by 36
Self-citationThe rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests
Zavorsky, G. S. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.01.001 · Cited by 36
Self-citationThe significant blood resistance to lung nitric oxide transfer lies within the red cell
Borland, C. D. R., Bottrill, F. E., Jones, A. R. C., Sparkes, C., & Vuylsteke, A. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00786.2013 · Cited by 35
Self-citationMembrane diffusion of the lungs in patients with chronic renal failure
Moinard, J., & Guénard, H. J.-P. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06020225 · Cited by 35
Self-citationIncreased Carbon Monoxide Clearance during Exercise in Humans
Zavorsky, G. S., Smoliga, J. M., Longo, L. D., Uhranowsky, K., Cadman, C. R., Duffin, J., & Fisher, J. A. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182602a00 · Cited by 32
Self-citationMartinot, J., Mulè, M., de Bisschop, C., Overbeek, M. J., Lê-Dông, N.-N., Naeije, R., & Guénard, H. J.-P. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01455.2012 · Cited by 30
Self-citationShort term variability of single breath carbon monoxide transfer factor
Robson, A. G. (2001) · Thorax · doi:10.1136/thorax.56.5.358 · Cited by 29
Can a membrane oxygenator be a model for lung NO and CO transfer?
Borland, C. D. R., Dunningham, H., Bottrill, F. E., & Vuylsteke, A. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00949.2005 · Cited by 28
Self-citationPulmonary capillary reserve and exercise capacity at high altitude in healthy humans
Taylor, B. J., Coffman, K. E., Summerfield, D. T., Issa, A. N., Kasak, A. J., & Johnson, B. D. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3299-1 · Cited by 26
Facing the Noise: Addressing the Endemic Variability in D LCO Testing
McCormack, M. C. (2012) · Respiratory Care · doi:10.4187/respcare.01435 · Cited by 22
Pulmonary Diffusing Capacity for Nitric Oxide During Exercise in Morbid Obesity
Zavorsky, G. S., Kim, D. J., McGregor, E. R., Starling, J. M., & Gavard, J. A. (2008) · Obesity · doi:10.1038/oby.2008.402 · Cited by 20
Self-citationCO and NO pulmonary diffusing capacity during pregnancy: Safety and diagnostic potential
Zavorsky, G. S., Blood, A. B., Power, G. G., Longo, L. D., Artal, R., & Vlastos, E. J. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.02.001 · Cited by 18
Self-citationAlexanderson, C., Olin, A., Dahlman‐Höglund, A., Finizia, C. A., & Torén, K. (2012) · American Journal of Rhinology and Allergy · doi:10.2500/ajra.2012.26.3777 · Cited by 17
Coffman, K. E., Taylor, B. J., Carlson, A. R., Wentz, R. J., & Johnson, B. D. (2015) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2015.10.016 · Cited by 16
No red cell resistance to NO? I think not!
Zavorsky, G. S. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00240.2010 · Cited by 15
Self-citationRouatbi, S., Saad, H. B., Latiri, I., Tabka, Z., & Guénard, H. J.-P. (2010) · Respiration · doi:10.1159/000316339 · Cited by 14
Self-citationBorland, C. D. R., Chamberlain, A. T., Higenbottam, T., Barber, R., & THRUSH, B. (1985) · Beiträge zur Tabakforschung international · doi:10.2478/cttr-2013-0557 · Cited by 12
Self-citationBorland, C. D. R. (1990) · PubMed · Cited by 10
Self-citationLung diffusing capacity for nitric oxide at lowered and raised ambient pressures
Linnarsson, D., Hemmingsson, T. E., FROSTELL, C. G., Muylem, A. V., Kerckx, Y., & Gustafsson, L. E. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.08.008 · Cited by 9
Dynamic vs. fixed bag filling: Impact on cardiac output rebreathing protocol
Zavorsky, G. S., Beck, K. C., Cass, L. M., Artal, R., & Wagner, P. D. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.01.006 · Cited by 8
Self-citation
Metadata
- Authors
- Zavorsky, G. S., Hsia, C. C. W., Hughes, J. M. B., Borland, C. D. R., Guénard, H., van der Lee, I., Steenbruggen, I., Naeije, R., Cao, J., & Dinh-Xuan, A. T.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2017-02
- Volume
- 49
- Issue
- 2
- Pages
- 1600962
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2587545449
- Cited by
- 163
- References
- 66
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.