CoChat

The effect of fluid overload on sleep apnoea severity in haemodialysis patients

Open access

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

As in heart failure, obstructive and central sleep apnoea (OSA and CSA, respectively) are common in end-stage renal disease. Fluid overload characterises end-stage renal disease and heart failure, and in heart failure plays a role in the pathogenesis of OSA and CSA. We postulated that in end-stage renal disease patients, those with sleep apnoea would have greater fluid volume overload than those without. End-stage renal disease patients on thrice-weekly haemodialysis underwent overnight polysomnography on a nondialysis day to determine their apnoea–hypopnoea index (AHI). Extracellular fluid volume of the total body, neck, thorax and right leg were measured using bioelectrical impedance. 28 patients had an AHI ≥15 (sleep apnoea group; OSA:CSA 21:7) and 12 had an AHI <15 (no sleep apnoea group). Total body extracellular fluid volume was 2.6 L greater in the sleep apnoea group than in the no sleep apnoea group (p=0.006). Neck, thorax, and leg fluid volumes were also greater in the sleep apnoea than the no sleep apnoea group (p<0.05), despite no difference in body mass index (p=0.165). These findings support a role for fluid overload in the pathogenesis of both OSA and CSA in end-stage renal disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/13993003.01789-2016

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

Metadata

Authors
Lyons, O. D., Inami, T., Perger, E., Yadollahi, A., Chan, C. T., & Bradley, T. D.
Affiliations
University Health Network (CA)
Venue
European Respiratory Journal
Published
2017-04
Volume
49
Issue
4
Pages
1601789
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2604987518
Cited by
56
References
32
Citations by year
2026: 3 · 2025: 2 · 2024: 8 · 2023: 12 · 2022: 6 · 2021: 4 · 2020: 5 · 2019: 10 · 2018: 3 · 2017: 3
FWCI
4.26
Type
journal article
Language
en
Open access
Locations
  • European Respiratory Journal (publishedVersion)
  • PubMed (publishedVersion)
  • BOA (University of Milano-Bicocca) (submittedVersion)
Funders
  • Canadian Institutes of Health Research (Operating grant MOP-82731)
  • Canadian Thoracic Society (Peter Macklem Fellowship)
  • European Respiratory Society (Peter Macklem Fellowship)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
fluid overload, sleep apnea, obstructive sleep apnea, central sleep apnea, hemodialysis, end-stage renal disease, extracellular volume, apnea-hypopnea index, polysomnography, bioimpedance
MeSH terms
Adult, Female, Heart Failure, Renal Dialysis, Humans, Kidney Failure, Chronic, Male, Middle Aged, Severity of Illness Index, Sleep Apnea Syndromes, Body Mass Index, Logistic Models, Electric Impedance, Polysomnography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.