flowClust: a Bioconductor package for automated gating of flow cytometry data
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: As a high-throughput technology that offers rapid quantification of multidimensional characteristics for millions of cells, flow cytometry (FCM) is widely used in health research, medical diagnosis and treatment, and vaccine development. Nevertheless, there is an increasing concern about the lack of appropriate software tools to provide an automated analysis platform to parallelize the high-throughput data-generation platform. Currently, to a large extent, FCM data analysis relies on the manual selection of sequential regions in 2-D graphical projections to extract the cell populations of interest. This is a time-consuming task that ignores the high-dimensionality of FCM data. RESULTS: In view of the aforementioned issues, we have developed an R package called flowClust to automate FCM analysis. flowClust implements a robust model-based clustering approach based on multivariate t mixture models with the Box-Cox transformation. The package provides the functionality to identify cell populations whilst simultaneously handling the commonly encountered issues of outlier identification and data transformation. It offers various tools to summarize and visualize a wealth of features of the clustering results. In addition, to ensure its convenience of use, flowClust has been adapted for the current FCM data format, and integrated with existing Bioconductor packages dedicated to FCM analysis. CONCLUSION: flowClust addresses the issue of a dearth of software that helps automate FCM analysis with a sound theoretical foundation. It tends to give reproducible results, and helps reduce the significant subjectivity and human time cost encountered in FCM analysis. The package contributes to the cytometry community by offering an efficient, automated analysis platform which facilitates the active, ongoing technological advancement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444 · cited 1×
“Please refer to [30] for a detailed account of an Expectation-Maximization (EM) algorithm [36] for the simultaneous estimation of all unknown parameters Ψ = ( Ψ 1 ,..., Ψ G ) where Ψ g = ( w g , μ g , Σ g , ν g , λ g ).”
Estimating the Dimension of a Model
Schwarz, G. (1978) · The Annals of Statistics · doi:10.1214/aos/1176344136 · Cited by 47,033 · cited 1×
“When the number of clusters is unknown, we use the Bayesian Information Criterion (BIC) [37], which gives good results in the context of mixture models [29,38].”
MethodBioconductor: open software development for computational biology and bioinformatics
Gentleman, R. C., Carey, V. J., Bates, D. M., Bolstad, B., Dettling, M., Dudoit, S., Ellis, B., Gautier, L., Ge, Y., Gentry, J., et al. (2004) · Genome Biology · doi:10.1186/gb-2004-5-10-r80 · Cited by 12,172 · cited 2×
“…utilization of system resources and makes use of the Basic Linear Algebra Subprograms (BLAS) library, which facilitates multithreaded processes when an optimized library is provided. flowClust is released through Bioconductor [24], along with those R packages mentioned in the Background section.”
MethodMcLachlan, G., & Peel, D. (2000) · Wiley Series in Probability and Statistics · doi:10.1002/0471721182 · Cited by 10,991
Model-Based Clustering, Discriminant Analysis, and Density Estimation
Fraley, C., & Raftery, A. E. (2002) · Journal of the American Statistical Association · doi:10.1198/016214502760047131 · Cited by 4,257 · cited 4×
“…clustering approach, we have developed the flowClust package (Additional file 1) to help resolve the current bottleneck. flowClust implements a robust model-based clustering approach [27-29] which extends the multivariate t mixture model with the Box-Cox transformation originally proposed in [30].”
BackgroundMethodInfluentialStatistical Analysis of Finite Mixture Distributions.
Lindsay, B. G., Titterington, D. M., Smith, A. F. M., & Makov, U. E. (1987) · Journal of the American Statistical Association · doi:10.2307/2289504 · Cited by 2,905
How Many Clusters? Which Clustering Method? Answers Via Model-Based Cluster Analysis
Fraley, C. (1998) · The Computer Journal · doi:10.1093/comjnl/41.8.578 · Cited by 2,549 · cited 1×
“When the number of clusters is unknown, we use the Bayesian Information Criterion (BIC) [37], which gives good results in the context of mixture models [29,38].”
MethodModel-Based Gaussian and Non-Gaussian Clustering
Banfield, J. D., & Raftery, A. E. (1993) · Biometrics · doi:10.2307/2532201 · Cited by 2,395 · cited 1×
“The most commonly used model-based clustering approach is based on finite Gaussian mixture models, which have been shown to give good results in various applied fields [28,29,33,34].”
MethodMixture models : inference and applications to clustering
McLachlan, G. J., & Basford, K. E. (1988) · M. Dekker eBooks · Cited by 2,094
Mixture Models: Inference and Applications to Clustering.
Lindsay, B., McLachlan, G. L., Basford, K. E., & Dekker, M. (1989) · Journal of the American Statistical Association · doi:10.2307/2289892 · Cited by 1,062
Robust mixture modelling using the t distribution
Peel, D., & McLachlan, G. J. (2000) · Statistics and Computing · doi:10.1023/a:1008981510081 · Cited by 947 · cited 2×
“In view of this, we have proposed in [30] an approach based on t mixture models [27,28] with the Box-Cox transformation to handle these two issues simultaneously.”
MethodCurrent Protocols in Cytometry
(2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471142956 · Cited by 862
Flow cytometry of apoptotic cell death
Vermes, I., Haanen, C., & Reutelingsperger, C. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00233-7 · Cited by 789 · cited 1×
“The technology is also used in cross-matching organs for transplantation and in research involving stem cells, vaccine development, apoptosis, phagocytosis, and a wide range of cellular properties including phenotype, cytokine expression, and cell-cycle status [9-14].”
MethodAnalysis of Cell Cycle by Flow Cytometry
Pozarowski, P., & Darzynkiewicz, Z. (2004) · Checkpoint Controls and Cancer · doi:10.1385/1-59259-811-0:301 · Cited by 585 · cited 1×
“The technology is also used in cross-matching organs for transplantation and in research involving stem cells, vaccine development, apoptosis, phagocytosis, and a wide range of cellular properties including phenotype, cytokine expression, and cell-cycle status [9-14].”
MethodflowCore: a Bioconductor package for high throughput flow cytometry
Hahne, F., LeMeur, N., Brinkman, R. R., Ellis, B., Haaland, P., Sarkar, D., Spidlen, J., Strain, E., & Gentleman, R. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-106 · Cited by 581
Self-citationAn Analysis of Transformations Revisited
Bickel, P. J., & Doksum, K. A. (1981) · Journal of the American Statistical Association · doi:10.1080/01621459.1981.10477649 · Cited by 551 · cited 1×
“…g ( ν g > 1), covariance matrix ν g ( ν g - 2) -1 Σ g ( ν g > 2) and ν g degrees of freedom. is the value obtained upon transforming y i with the Box-Cox parameter λ g ; the transformation used is a variant of the original Box-Cox transformation which is also defined for negative-valued data [35].”
MethodMCLUST Version 3 for R: Normal Mixture Modeling and Model-Based Clustering †
Fraley, C., & Raftery, A. E. (2007) · Cited by 389
Krutzik, P. O., Irish, J. M., Nolan, G. P., & Perez, O. D. (2004) · Clinical Immunology · doi:10.1016/j.clim.2003.11.009 · Cited by 335 · cited 1×
“The technology is also used in cross-matching organs for transplantation and in research involving stem cells, vaccine development, apoptosis, phagocytosis, and a wide range of cellular properties including phenotype, cytokine expression, and cell-cycle status [9-14].”
MethodMCLUST Version 3: An R Package for Normal Mixture Modeling and Model-Based Clustering
Fraley, C., & Raftery, A. E. (2006) · doi:10.21236/ada456562 · Cited by 331
Automated gating of flow cytometry data via robust model‐based clustering
Lo, K., Brinkman, R. R., & Gottardo, R. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20531 · Cited by 264 · cited 7×
“Please refer to [30] for a detailed account of an Expectation-Maximization (EM) algorithm [36] for the simultaneous estimation of all unknown parameters Ψ = ( Ψ 1 ,..., Ψ G ) where Ψ g = ( w g , μ g , Σ g , ν g , λ g ).”
MethodInfluentialSelf-citationFlow cytometric measurement of intracellular cytokines
Pala, P., Hussell, T., & Openshaw, P. J. M. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00230-1 · Cited by 222 · cited 1×
“The technology is also used in cross-matching organs for transplantation and in research involving stem cells, vaccine development, apoptosis, phagocytosis, and a wide range of cellular properties including phenotype, cytokine expression, and cell-cycle status [9-14].”
MethodCurrent Protocols In Cytometry
Robinson (1997) · Cited by 208
Beyond six colors: A new era in flow cytometry
De Rosa, S. C., Brenchley, J. M., & Roederer, M. (2003) · Nature Medicine · doi:10.1038/nm0103-112 · Cited by 208
Programming With Data: A Guide to the S Language
Bates, D. M. (1999) · Technometrics · doi:10.1080/00401706.1999.10485682 · Cited by 204
Phagocytosis: measurement by flow cytometry
Lehmann, A. K., Sørnes, S., & Halstensen, A. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00237-4 · Cited by 191 · cited 1×
“The technology is also used in cross-matching organs for transplantation and in research involving stem cells, vaccine development, apoptosis, phagocytosis, and a wide range of cellular properties including phenotype, cytokine expression, and cell-cycle status [9-14].”
MethodProbability binning comparison: A metric for quantitating univariate distribution differences
Roederer, M., Treister, A., Moore, W., & Herzenberg, L. A. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<37::aid-cyto1142>3.0.co;2-e · Cited by 186 · cited 1×
“There is considerable demand for the development of appropriate software tools, as manual analysis of individual samples is error-prone, non-reproducible, non-standardized, not open to re-evaluation, and requires an inordinate amount of time, making it a limiting aspect of the technology [1,7,15-21].”
BackgroundImmunophenotyping of acute leukemias and myelodysplastic syndromes
Órfão, A., Ortuño, F. J., de Santiago, M., López, A., & Miguel, J. F. S. (2004) · Cytometry Part A · doi:10.1002/cyto.a.10104 · Cited by 118 · cited 1×
“helper-T lymphocytes needed to monitor the course and treatment of HIV infection, in the diagnosis and monitoring of leukemia and lymphoma patients, the evaluation of peripheral blood hematopoietic stem cell grafts, and many other diseases [1-8].”
BackgroundProbability binning comparison: a metric for quantitating multivariate distribution differences
Roederer, M., Moore, W., Treister, A., Hardy, R. R., & Herzenberg, L. A. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<47::aid-cyto1143>3.0.co;2-a · Cited by 97 · cited 1×
“There is considerable demand for the development of appropriate software tools, as manual analysis of individual samples is error-prone, non-reproducible, non-standardized, not open to re-evaluation, and requires an inordinate amount of time, making it a limiting aspect of the technology [1,7,15-21].”
BackgroundBrinkman, R. R., Gasparetto, M., Lee, S.-J. J., Ribickas, A. J., Perkins, J. B., Janssen, W. E., Smiley, R., & Smith, C. A. (2007) · Transplantation and Cellular Therapy · doi:10.1016/j.bbmt.2007.02.002 · Cited by 79 · cited 4×
“For demonstration, we use the graft-versus-host disease (GvHD) data (Additional file 2) [40].”
BackgroundMethodInfluentialSelf-citationUsing flowViz to visualize flow cytometry data
Sarkar, D., Meur, N. L., & Gentleman, R. C. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn021 · Cited by 71 · cited 1×
“…source software development project for the analysis of genomic data. flowCore [25], the core package among them, provides data structures and basic manipulation of FCM data. flowViz [26] offers visualization tools, while flowQ provides quality control and quality assessment tools for FCM data.”
MethodPerformance of plate-based cytokine flow cytometry with automated data analysis
Suni, M. A., Dunn, H. S., Orr, P. L., de Laat, R., Sinclair, E., Ghanekar, S., Bredt, B. M., Dunne, J. F., Maino, V. C., & Maecker, H. T. (2003) · BMC Immunology · doi:10.1186/1471-2172-4-9 · Cited by 53 · cited 1×
“This process is manually timeconsuming and subjective as researchers have traditionally relied on intuition rather than standardized statistical inference [7,22,23].”
Genomics, Transcriptomics, Proteomics, and Numbers
Kiechle, F. L., & Holland-Staley, C. A. (2003) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2003-127-1089-gtpan · Cited by 38
Data Standards for Flow Cytometry
Špidlen, J., Gentleman, R. C., Haaland, P., Langille, M. G. I., Meur, N. L., Ochs, M. F., Schmitt, C., Smith, C. A., Treister, A., & Brinkman, R. R. (2006) · OMICS A Journal of Integrative Biology · doi:10.1089/omi.2006.10.209 · Cited by 34 · cited 1×
“…is considerable demand for the development of appropriate software tools, as manual analysis of individual samples is error-prone, non-reproducible, non-standardized, not open to re-evaluation, and requires an inordinate amount of time, making it a limiting aspect of the technology [1,7,15-21].”
BackgroundSelf-citationLizard, G. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20444 · Cited by 25
Twenty‐five years of clinical flow cytometry: AIDS accelerated global instrument distribution
Mandy, F. F. (2004) · Cytometry Part A · doi:10.1002/cyto.a.10102 · Cited by 24 · cited 1×
“helper-T lymphocytes needed to monitor the course and treatment of HIV infection, in the diagnosis and monitoring of leukemia and lymphoma patients, the evaluation of peripheral blood hematopoietic stem cell grafts, and many other diseases [ 1-8 ].”
BackgroundA new spreadsheet method for the analysis of bivariate flow cytometric data
Tzircotis, G., Thorne, R. F., & Isacke, C. M. (2004) · BMC Cell Biology · doi:10.1186/1471-2121-5-10 · Cited by 16
Cited by
FlowSOM: Using self‐organizing maps for visualization and interpretation of cytometry data
Van Gassen, S., Callebaut, B., Van Helden, M. J., Lambrecht, B. N., Demeester, P., Dhaene, T., & Saeys, Y. (2015) · Cytometry Part A · doi:10.1002/cyto.a.22625 · Cited by 1,919
Neural networks: An overview of early research, current frameworks and new challenges
Prieto, A., Prieto, B., Ortigosa, E. M., Ros, E., Pelayo, F., Ortega, J., & Rojas, I. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.06.014 · Cited by 391
Comparison of clustering methods for high‐dimensional single‐cell flow and mass cytometry data
Weber, L. M., & Robinson, M. D. (2016) · Cytometry Part A · doi:10.1002/cyto.a.23030 · Cited by 378
Finak, G., Frelinger, J., Jiang, W., Newell, E. W., Ramey, J., Davis, M. M., Kalams, S. A., De Rosa, S. C., & Gottardo, R. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003806 · Cited by 197
“OpenCyto Pipelines Are Flexible and Extensible OpenCyto supports a number of different built-in automated gating algorithms, including high-dimensional model-based methods (flowClust) [31], density-based methods (mindensity, flowDensity), rare cell population identification (tailgate, quantileGate), and various specia…”
MethodSelf-citationMeasurement and modeling of intrinsic transcription terminators
Cambray, G., Guimaraes, J. C., Mutalik, V. K., Lam, C., Mai, Q.-A., Thimmaiah, T., Carothers, J. M., Arkin, A. P., & Endy, D. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt163 · Cited by 188
“Raw data were filtered using an automated gating strategy (29) to ensure consistent distributions of TRCELL ratio [Equation (1), Supplementary Figure S4].”
Method
Metadata
- Authors
- Lo, K., Hahne, F., Brinkman, R. R., & Gottardo, R.
- Venue
- BMC Bioinformatics
- Published
- 2009-05-14
- Volume
- 10
- Issue
- 1
- Pages
- 145-145
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2009474665
- Cited by
- 185
- References
- 36
- FWCI
- 9.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.