The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
xMSanalyzer: automated pipeline for improved feature detection and downstream analysis of large-scale, non-targeted metabolomics data
Open accessAbstract
Background: Detection of low abundance metabolites is important for de novo mapping of metabolic pathways related to diet, microbiome or environmental exposures. Multiple algorithms are available to extract m/z features from liquid chromatography-mass spectral data in a conservative manner, which tends to preclude detection of low abundance chemicals and chemicals found in small subsets of samples. The present study provides software to enhance such algorithms for feature detection, quality assessment, and annotation. Results: xMSanalyzer is a set of utilities for automated processing of metabolomics data. The utilites can be classified into four main modules to: 1) improve feature detection for replicate analyses by systematic re-extraction with multiple parameter settings and data merger to optimize the balance between sensitivity and reliability, 2) evaluate sample quality and feature consistency, 3) detect feature overlap between datasets, and 4) characterize high-resolution m/z matches to small molecule metabolites and biological pathways using multiple chemical databases. The package was tested with plasma samples and shown to more than double the number of features extracted while improving quantitative reliability of detection. MS/MS analysis of a random subset of peaks that were exclusively detected using xMSanalyzer confirmed that the optimization scheme improves detection of real metabolites. Conclusions: xMSanalyzer is a package of utilities for data extraction, quality control assessment, detection of overlapping and unique metabolites in multiple datasets, and batch annotation of metabolites. The program was designed to integrate with existing packages such as apLCMS and XCMS, but the framework can also be used to enhance data extraction for other LC/MS data software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262
Pluskal, T., Castillo, S., Villar-Briones, A., & Orešič, M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-395 · Cited by 3,845
Mass spectrometry‐based metabolomics
Dettmer, K., Aronov, P. A., & Hammock, B. D. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20108 · Cited by 2,241
METLIN—a metabolite mass spectral database
Smith, C. A., Maille, G. O., Want, E. J., Qin, C., Trauger, S. A., Brandon, T. R., Custodio, D. E., Abagyan, R., & Siuzdak, G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000179845.53213.39 · Cited by 2,226
MZmine: toolbox for processing and visualization of mass spectrometry based molecular profile data
Katajamaa, M., Miettinen, J., & Orešič, M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btk039 · Cited by 831
OpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Sensitivity Analysis for Chemical Models
Saltelli, A., Ratto, M., Tarantola, S., & Campolongo, F. (2005) · Chemical Reviews · doi:10.1021/cr040659d · Cited by 639
Kind, T., & Fiehn, O. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-234 · Cited by 637
Metabolite identification via the Madison Metabolomics Consortium Database
Cui, Q., Lewis, I. A., Hegeman, A. D., Anderson, M. E., Li, J., Schulte, C. F., Westler, W. M., Eghbalnia, H. R., Sussman, M. R., & Markley, J. L. (2008) · Nature Biotechnology · doi:10.1038/nbt0208-162 · Cited by 632
apLCMS—adaptive processing of high-resolution LC/MS data
Yu, T., Park, Y., Johnson, J. M., & Jones, D. P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp291 · Cited by 406
Self-citation
Cited by
An expanded evaluation of protein function prediction methods shows an improvement in accuracy
Jiang, Y., Oron, T. R., Clark, W. T., Bankapur, A. R., D’Andrea, D., Lepore, R., Funk, C. S., Kahanda, I., Verspoor, K. M., Ben-Hur, A., et al. (2016) · Genome Biology · doi:10.1186/s13059-016-1037-6 · Cited by 396
Self-citationSampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Self-citationIPO: a tool for automated optimization of XCMS parameters
Libiseller, G., Dvorzak, M., Kleb, U., Gander, E., Eisenberg, T., Madeo, F., Neumann, S., Trausinger, G., Sinner, F., Pieber, T., et al. (2015) · BMC Bioinformatics · doi:10.1186/s12859-015-0562-8 · Cited by 342
Go, Y.-M., & Jones, D. P. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.r113.464131 · Cited by 260
Self-citationChen, Z., Yang, T., Walker, D. I., Thomas, D. C., Qiu, C., Chatzi, L., Alderete, T. L., Kim, J. S., Conti, D. V., Breton, C. V., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.106091 · Cited by 176
Metadata
- Authors
- Uppal, K., Soltow, Q. A., Strobel, F. H., Pittard, W. S., Gernert, K. M., Yu, T., & Jones, D. P.
- Venue
- BMC Bioinformatics
- Published
- 2013-01-16
- Volume
- 14
- Issue
- 1
- Pages
- 15-15
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2012660994
- Cited by
- 372
- References
- 25
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: xMSanalyzer: automated pipeline for improved feature detection and downstream analysis of large-scale, non-targeted metabolomics data. https://app.cochat.ai/papers/10.1186/1471-2105-14-15
- The paper
- Uppal, K., Soltow, Q. A., Strobel, F. H., Pittard, W. S., Gernert, K. M., Yu, T., & Jones, D. P. (2013). xMSanalyzer: automated pipeline for improved feature detection and downstream analysis of large-scale, non-targeted metabolomics data. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-14-15
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.