xMSanalyzer: automated pipeline for improved feature detection and downstream analysis of large-scale, non-targeted metabolomics data
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: Detection of low abundance metabolites is important for de novo mapping of metabolic pathways related to diet, microbiome or environmental exposures. Multiple algorithms are available to extract m/z features from liquid chromatography-mass spectral data in a conservative manner, which tends to preclude detection of low abundance chemicals and chemicals found in small subsets of samples. The present study provides software to enhance such algorithms for feature detection, quality assessment, and annotation. Results: xMSanalyzer is a set of utilities for automated processing of metabolomics data. The utilites can be classified into four main modules to: 1) improve feature detection for replicate analyses by systematic re-extraction with multiple parameter settings and data merger to optimize the balance between sensitivity and reliability, 2) evaluate sample quality and feature consistency, 3) detect feature overlap between datasets, and 4) characterize high-resolution m/z matches to small molecule metabolites and biological pathways using multiple chemical databases. The package was tested with plasma samples and shown to more than double the number of features extracted while improving quantitative reliability of detection. MS/MS analysis of a random subset of peaks that were exclusively detected using xMSanalyzer confirmed that the optimization scheme improves detection of real metabolites. Conclusions: xMSanalyzer is a package of utilities for data extraction, quality control assessment, detection of overlapping and unique metabolites in multiple datasets, and batch annotation of metabolites. The program was designed to integrate with existing packages such as apLCMS and XCMS, but the framework can also be used to enhance data extraction for other LC/MS data software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262
Pluskal, T., Castillo, S., Villar-Briones, A., & Orešič, M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-395 · Cited by 3,845
Mass spectrometry‐based metabolomics
Dettmer, K., Aronov, P. A., & Hammock, B. D. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20108 · Cited by 2,241
METLIN—a metabolite mass spectral database
Smith, C. A., Maille, G. O., Want, E. J., Qin, C., Trauger, S. A., Brandon, T. R., Custodio, D. E., Abagyan, R., & Siuzdak, G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000179845.53213.39 · Cited by 2,226
MZmine: toolbox for processing and visualization of mass spectrometry based molecular profile data
Katajamaa, M., Miettinen, J., & Orešič, M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btk039 · Cited by 831
OpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Sensitivity Analysis for Chemical Models
Saltelli, A., Ratto, M., Tarantola, S., & Campolongo, F. (2005) · Chemical Reviews · doi:10.1021/cr040659d · Cited by 639
Kind, T., & Fiehn, O. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-234 · Cited by 637
Metabolite identification via the Madison Metabolomics Consortium Database
Cui, Q., Lewis, I. A., Hegeman, A. D., Anderson, M. E., Li, J., Schulte, C. F., Westler, W. M., Eghbalnia, H. R., Sussman, M. R., & Markley, J. L. (2008) · Nature Biotechnology · doi:10.1038/nbt0208-162 · Cited by 632
apLCMS—adaptive processing of high-resolution LC/MS data
Yu, T., Park, Y., Johnson, J. M., & Jones, D. P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp291 · Cited by 406
Self-citation
Cited by
Honokiol blocks and reverses cardiac hypertrophy in mice by activating mitochondrial Sirt3
Pillai, V. B., Samant, S., Sundaresan, N. R., Raghuraman, H., Kim, G., Bonner, M. Y., Arbiser, J. L., Walker, D. I., Jones, D. P., Gius, D., et al. (2015) · Nature Communications · doi:10.1038/ncomms7656 · Cited by 445
Self-citationAn expanded evaluation of protein function prediction methods shows an improvement in accuracy
Jiang, Y., Oron, T. R., Clark, W. T., Bankapur, A. R., D’Andrea, D., Lepore, R., Funk, C. S., Kahanda, I., Verspoor, K. M., Ben-Hur, A., et al. (2016) · Genome Biology · doi:10.1186/s13059-016-1037-6 · Cited by 396
Self-citationSampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Self-citationIPO: a tool for automated optimization of XCMS parameters
Libiseller, G., Dvorzak, M., Kleb, U., Gander, E., Eisenberg, T., Madeo, F., Neumann, S., Trausinger, G., Sinner, F., Pieber, T., et al. (2015) · BMC Bioinformatics · doi:10.1186/s12859-015-0562-8 · Cited by 342
xMSannotator: An R Package for Network-Based Annotation of High-Resolution Metabolomics Data
Uppal, K., Walker, D. I., & Jones, D. P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01214 · Cited by 297
Self-citationGo, Y.-M., & Jones, D. P. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.r113.464131 · Cited by 260
“The recent development of high resolution metabolomics using high resolutionMS and advanced data extraction (96, 97) has provided the capability to measure 20,000 chemicals in biologic extracts.”
BackgroundSelf-citationThe Exposome: Molecules to Populations
Niedzwiecki, M. M., Walker, D. I., Vermeulen, R., Chadeau-Hyam, M., Jones, D. P., & Miller, G. W. (2019) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010818-021315 · Cited by 248
Self-citationGo, Y.-M., Walker, D. I., Liang, Y., Uppal, K., Soltow, Q. A., Tran, V., Strobel, F., Quyyumi, A. A., Ziegler, T. R., Pennell, K. D., et al. (2015) · Toxicological Sciences · doi:10.1093/toxsci/kfv198 · Cited by 244
“The data were processed for peak extraction and quantification of ion intensities using xMSanalyzer (MS(1) mode) (Uppal et al., 2013) with apLCMS (Yu et al.”
BackgroundMethodSelf-citationComputational Metabolomics: A Framework for the Million Metabolome
Uppal, K., Walker, D. I., Liu, K., Li, S., Go, Y.-M., & Jones, D. P. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00179 · Cited by 244
“Advanced computational methods facilitate detection of more than 35,000 ions from biological samples by LCMS; 13 feasibility studies show, however, that variation of data extraction parameters, e.g., increasing tolerance for coefficient of variation and % missing values, can allow detection of…”
InfluentialSelf-citationJin, R., McConnell, R., Catherine, C., Xu, S., Walker, D. I., Stratakis, N., Jones, D. P., Miller, G. W., Peng, C., Conti, D. V., et al. (2020) · Environment International · doi:10.1016/j.envint.2019.105220 · Cited by 219
“2013) with modifications by xMSanalyzer,(Uppal et al. 2013) which included batch correction using ComBat,(Johnson et al.”
MethodSelf-citationReference Standardization for Quantification and Harmonization of Large-Scale Metabolomics
Liu, K. H., Nellis, M., Uppal, K., Ma, C., Tran, V., Liang, Y., Walker, D. I., & Jones, D. P. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00338 · Cited by 203
Self-citationGOLabeler: improving sequence-based large-scale protein function prediction by learning to rank
You, R., Zhang, Z., Xiong, Y., Sun, F., Mamitsuka, H., & Zhu, S. (2018) · Bioinformatics · doi:10.1093/bioinformatics/bty130 · Cited by 199
Metabolomics technology and bioinformatics for precision medicine
Azad, R. K., & Shulaev, V. (2019) · Briefings in Bioinformatics · doi:10.1093/bib/bbx170 · Cited by 180
Chen, Z., Yang, T., Walker, D. I., Thomas, D. C., Qiu, C., Chatzi, L., Alderete, T. L., Kim, J. S., Conti, D. V., Breton, C. V., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.106091 · Cited by 176
“(Uppal et al., 2013) Uniquely detected ions consisted of m/z, retention time and ion abundance, referred to as metabolomic features.”
BackgroundKell, D. B., & Goodacre, R. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.07.014 · Cited by 169
Chang, C.-J., Barr, D. B., Ryan, P. B., Panuwet, P., Smarr, M. M., Liu, K., Kannan, K., Yakimavets, V., Tan, Y., Ly, V., et al. (2022) · Environment International · doi:10.1016/j.envint.2021.106964 · Cited by 166
Self-citationAlderete, T. L., Jin, R., Walker, D. I., Valvi, D., Chen, Z., Jones, D. P., Peng, C., Gilliland, F. D., Berhane, K., Conti, D. V., et al. (2019) · Environment International · doi:10.1016/j.envint.2019.02.047 · Cited by 162
“, 2009) with modifications by xMSanalyzer (Uppal et al., 2013).”
Self-citationLiang, D., Moutinho, J. L., Golan, R., Yu, T., Ladva, C. N., Niedzwiecki, M., Walker, D. I., Sarnat, S. E., Chang, H. H., Greenwald, R., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.07.044 · Cited by 158
“mzML files using ProteoWizard and extracted using apLCMS with modifications by xMSanalyzer (Uppal et al., 2013; Yu et al., 2009).”
Self-citationA roadmap for the XCMS family of software solutions in metabolomics
Mahieu, N. G., Genenbacher, J. L., & Patti, G. J. (2016) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2015.11.009 · Cited by 151
Guo, P., Furnary, T., Vasiliou, V., Yan, Q., Nyhan, K., Jones, D. P., Johnson, C. H., & Liew, Z. (2022) · Environment International · doi:10.1016/j.envint.2022.107159 · Cited by 145
Self-citationHigh-resolution metabolomics of occupational exposure to trichloroethylene
Walker, D. I., Uppal, K., Zhang, L., Vermeulen, R., Smith, M., Hu, W., Purdue, M. P., Tang, X., Reiss, B., Kim, S., et al. (2016) · International Journal of Epidemiology · doi:10.1093/ije/dyw218 · Cited by 107
“Data were extracted with apLCMS(38) and xMSanalyser.(22) Full details and quality control are included in Supplementary Text 1.”
MethodSelf-citationMaternal serum metabolome and traffic-related air pollution exposure in pregnancy
Yan, Q., Liew, Z., Uppal, K., Cui, X., Ling, C., Heck, J. E., von Ehrenstein, O. S., Wu, J., Walker, D. I., Jones, D. P., et al. (2019) · Environment International · doi:10.1016/j.envint.2019.05.066 · Cited by 91
Self-citationMetabolomics of Childhood Exposure to Perfluoroalkyl Substances: A Cross-Sectional Study
Kingsley, S. L., Walker, D. I., Calafat, A. M., Chen, A., Papandonatos, G. D., Xu, Y., Jones, D. P., Lanphear, B. P., Pennell, K. D., & Braun, J. M. (2019) · Metabolomics · doi:10.1007/s11306-019-1560-z · Cited by 90
Self-citationCardiovascular Risk and Resilience Among Black Adults: Rationale and Design of the MECA Study
Islam, S. J., Kim, J. H., Topel, M., Liu, C., Ko, Y., Mujahid, M. S., Sims, M., Mubasher, M., Ejaz, K., Morgan‐Billingslea, J., et al. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.015247 · Cited by 23
Self-citationChang, C.-J., Young, A. S., Keil, A., Mullins, C. E., Liang, D., Zhao, S., Jones, D. P., Hu, X., Walker, D. I., & White, A. J. (2025) · Environment International · doi:10.1016/j.envint.2025.109590 · Cited by 16
Self-citation
Metadata
- Authors
- Uppal, K., Soltow, Q. A., Strobel, F. H., Pittard, W. S., Gernert, K. M., Yu, T., & Jones, D. P.
- Venue
- BMC Bioinformatics
- Published
- 2013-01-16
- Volume
- 14
- Issue
- 1
- Pages
- 15-15
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2012660994
- Cited by
- 372
- References
- 25
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.