The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparison of three next-generation sequencing platforms for metagenomic sequencing and identification of pathogens in blood
Open accessAbstract
BACKGROUND: The introduction of benchtop sequencers has made adoption of whole genome sequencing possible for a broader community of researchers than ever before. Concurrently, metagenomic sequencing (MGS) is rapidly emerging as a tool for interrogating complex samples that defy conventional analyses. In addition, next-generation sequencers are increasingly being used in clinical or related settings, for instance to track outbreaks. However, information regarding the analytical sensitivity or limit of detection (LoD) of benchtop sequencers is currently lacking. Furthermore, the specificity of sequence information at or near the LoD is unknown. RESULTS: In the present study, we assess the ability of three next-generation sequencing platforms to identify a pathogen (viral or bacterial) present in low titers in a clinically relevant sample (blood). Our results indicate that the Roche-454 Titanium platform is capable of detecting Dengue virus at titers as low as 1X102.5 pfu/mL, corresponding to an estimated 5.4X104 genome copies/ml maximum. The increased throughput of the benchtop sequencers, the Ion Torrent PGM and Illumina MiSeq platforms, enabled detection of viral genomes at concentrations as low as 1X104 genome copies/mL. Platform-specific biases were evident in sequence read distributions as well as viral genome coverage. For bacterial samples, only the MiSeq platform was able to provide sequencing reads that could be unambiguously classified as originating from Bacillus anthracis. CONCLUSION: The analytical sensitivity of all three platforms approaches that of standard qPCR assays. Although all platforms were able to detect pathogens at the levels tested, there were several noteworthy differences. The Roche-454 Titanium platform produced consistently longer reads, even when compared with the latest chemistry updates for the PGM platform. The MiSeq platform produced consistently greater depth and breadth of coverage, while the Ion Torrent was unequaled for speed of sequencing. None of the platforms were able to verify a single nucleotide polymorphism responsible for antiviral resistance in an Influenza A strain isolated from the 2009 H1N1 pandemic. Overall, the benchtop platforms perform well for identification of pathogens from a representative clinical sample. However, unlike identification, characterization of pathogens is likely to require higher titers, multiple libraries and/or multiple sequencing runs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quail, M., Smith, M. E., Coupland, P., Otto, T. D., Harris, S. R., Connor, T. R., Bertoni, A., Swerdlow, H. P., & Gu, Y. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-341 · Cited by 2,031 · cited 3×
“A closer examination of the mapped reads seems to show a slight correlation with areas of low G/C-content, but follow on experiments would be required to conclusively elucidate the impact of G/Ccontent in this context.”
Henderson, G., Cox, F., Kittelmann, S., Miri, V. H., Zethof, M., Noel, S. J., Waghorn, G. C., & Janssen, P. H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0074787 · Cited by 328
Cited by
Next generation sequencing and its applications in forensic genetics
Børsting, C., & Morling, N. (2015) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2015.02.002 · Cited by 460
Tan, B., Ng, C., Nshimyimana, J. P., Loh, L. L., Gin, K. Y.-H., & Thompson, J. R. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2015.01027 · Cited by 297
Ogunade, I. M., Jiang, Y., Pech Cervantes, A. A., Kim, D. H., Oliveira, A. S., Vyas, D., Weinberg, Z. G., Jeong, K. C., & Adesogan, A. T. (2018) · Journal of Dairy Science · doi:10.3168/jds.2017-12876 · Cited by 272
Comparing Apples and Oranges?: Next Generation Sequencing and Its Impact on Microbiome Analysis
Clooney, A. G., Fouhy, F., Sleator, R. D., O’ Driscoll, A., Stanton, C., Cotter, P. D., & Claesson, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148028 · Cited by 270
Next-Generation Sequencing for Infectious Disease Diagnosis and Management
Lefterova, M. I., Suarez, C. J., Banaei, N., & Pinsky, B. A. (2015) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2015.07.004 · Cited by 207
Metadata
- Authors
- Frey, K. G., Herrera-Galeano, J. E., Redden, C. L., Luu, T. V., Servetas, S. L., Mateczun, A. J., Mokashi, V. P., & Bishop-Lilly, K. A.
- Venue
- BMC Genomics
- Published
- 2014-02-04
- Volume
- 15
- Issue
- 1
- Pages
- 96-96
- ISSN
- 1471-2164 (ISSN-L)
- OpenAlex
- W2117654562
- Cited by
- 177
- References
- 2
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of three next-generation sequencing platforms for metagenomic sequencing and identification of pathogens in blood. https://app.cochat.ai/papers/10.1186/1471-2164-15-96
- The paper
- Frey, K. G., Herrera-Galeano, J. E., Redden, C. L., Luu, T. V., Servetas, S. L., Mateczun, A. J., Mokashi, V. P., & Bishop-Lilly, K. A. (2014). Comparison of three next-generation sequencing platforms for metagenomic sequencing and identification of pathogens in blood. BMC Genomics. https://doi.org/10.1186/1471-2164-15-96
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.