CoChat

A tale of three next generation sequencing platforms: comparison of Ion torrent, pacific biosciences and illumina MiSeq sequencers

Open access

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Next generation sequencing (NGS) technology has revolutionized genomic and genetic research. The pace of change in this area is rapid with three major new sequencing platforms having been released in 2011: Ion Torrent's PGM, Pacific Biosciences' RS and the Illumina MiSeq. Here we compare the results obtained with those platforms to the performance of the Illumina HiSeq, the current market leader. In order to compare these platforms, and get sufficient coverage depth to allow meaningful analysis, we have sequenced a set of 4 microbial genomes with mean GC content ranging from 19.3 to 67.7%. Together, these represent a comprehensive range of genome content. Here we report our analysis of that sequence data in terms of coverage distribution, bias, GC distribution, variant detection and accuracy. RESULTS: Sequence generated by Ion Torrent, MiSeq and Pacific Biosciences technologies displays near perfect coverage behaviour on GC-rich, neutral and moderately AT-rich genomes, but a profound bias was observed upon sequencing the extremely AT-rich genome of Plasmodium falciparum on the PGM, resulting in no coverage for approximately 30% of the genome. We analysed the ability to call variants from each platform and found that we could call slightly more variants from Ion Torrent data compared to MiSeq data, but at the expense of a higher false positive rate. Variant calling from Pacific Biosciences data was possible but higher coverage depth was required. Context specific errors were observed in both PGM and MiSeq data, but not in that from the Pacific Biosciences platform. CONCLUSIONS: All three fast turnaround sequencers evaluated here were able to generate usable sequence. However there are key differences between the quality of that data and the applications it will support.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2164-13-341

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Genome coverage plots for 15x depth randomly downsampled sequence coverage from the sequencing platforms tested. A) The percentage of the B. pertussis genome covered at different read depths; B) The number of bases covered at different depths for B. pertussis;C) The percentage of the S. aureus genome covered at different read depths; D) The number of bases covered at different depths for S. aureus;E) The percentage of the P. falciparum genome covered at different read depths; and F) The number of bases covered at different depths for P. falciparum.
Figure 1 Genome coverage plots for 15x depth randomly downsampled sequence coverage from the sequencing platforms tested. A) The percentage of the B. pertussis genome covered at different read depths; B) The number of bases covered at different depths for B. pertussis;C) The percentage of the S. aureus genome covered at different read depths; D) The number of bases covered at different depths for S. aureus;E) The percentage of the P. falciparum genome covered at different read depths; and F) The number of bases covered at different depths for P. falciparum.CC BY · PubMed Central
Figure 2 Artemis genome browser[8]screenshots illustrating the variation in sequence coverage of a selected region of P. falciparum chromosome 11, with 15x depth of randomly normalized sequence from the platforms tested. In each window, the top graph shows the percentage GC content at each position, with the numbers on the right denoting the minimum, average and maximum values. The middle graph in each window is a coverage plot for the dataset from each instrument; the colour code is shown above graph a). Each of the middle graphs shows the depth of reads mapped at each position, and below that in B-D are the coordinates of the selected region in the genome with gene models on the (+) strand above and (−) strand below. A) View of the first 200 kb of chromosome 11. Graphs are smoothed with window size of 1000. A heatmap of the errors, normalized by the amount of mapping reads is included just below the GC content graph (PacBio top line, PGM middle and MiSeq bottom). B) Coverage over region of extreme GC content, ranging from 70% to 0%. C) Coverage over the gene PF3D7_1103500. D) Example of intergenic region between genes PF3D7_1104200 and PF3D7_1104300. The window size of B, C and D is 50 bp.
Figure 2 Artemis genome browser[8]screenshots illustrating the variation in sequence coverage of a selected region of P. falciparum chromosome 11, with 15x depth of randomly normalized sequence from the platforms tested. In each window, the top graph shows the percentage GC content at each position, with the numbers on the right denoting the minimum, average and maximum values. The middle graph in each window is a coverage plot for the dataset from each instrument; the colour code is shown above graph a). Each of the middle graphs shows the depth of reads mapped at each position, and below that in B-D are the coordinates of the selected region in the genome with gene models on the (+) strand above and (−) strand below. A) View of the first 200 kb of chromosome 11. Graphs are smoothed with window size of 1000. A heatmap of the errors, normalized by the amount of mapping reads is included just below the GC content graph (PacBio top line, PGM middle and MiSeq bottom). B) Coverage over region of extreme GC content, ranging from 70% to 0%. C) Coverage over the gene PF3D7_1103500. D) Example of intergenic region between genes PF3D7_1104200 and PF3D7_1104300. The window size of B, C and D is 50 bp.CC BY · PubMed Central
Figure 3 The effect of substituting Platinum HiFi PCR supermix with Kapa HiFi in the PGM library prep amplification step. A) The percentage of the P. falciparum genome covered at different read depths. The blue line shows the data obtained with the recommended Platinum enzyme and the green line with Kapa HiFi. The red line depicts ideal coverage behavior. B) The number of bases covered at different depths. C) Sequence representation vs. GC-content plots.
Figure 3 The effect of substituting Platinum HiFi PCR supermix with Kapa HiFi in the PGM library prep amplification step. A) The percentage of the P. falciparum genome covered at different read depths. The blue line shows the data obtained with the recommended Platinum enzyme and the green line with Kapa HiFi. The red line depicts ideal coverage behavior. B) The number of bases covered at different depths. C) Sequence representation vs. GC-content plots.CC BY · PubMed Central
Figure 4 Illustration of platform-specific errors. The panels show Artemis BAM views with reads (horizontal bars) mapping to defined regions of chromosome 11 of P. falciparum from PacBio (P; top), Ion Torrent (I; middle) and MiSeq (M; bottom). Red vertical dashes are 1 base differences to the reference and white points are indels. A) Illustration of errors in Illumina data after a long homopolymer tract. Ion torrent data has a drop of coverage and multiple indels are visible in PacBio data. B) Example of errors associated with short homopolymer tracts. Multiple insertions are visible in the PacBio Data, deletions are observed in the PGM data and the MiSeq sequences read generally correct through the homopolymer tract. C) Example of strand specific deletions (red circles) observed in Ion Torrent data.
Figure 4 Illustration of platform-specific errors. The panels show Artemis BAM views with reads (horizontal bars) mapping to defined regions of chromosome 11 of P. falciparum from PacBio (P; top), Ion Torrent (I; middle) and MiSeq (M; bottom). Red vertical dashes are 1 base differences to the reference and white points are indels. A) Illustration of errors in Illumina data after a long homopolymer tract. Ion torrent data has a drop of coverage and multiple indels are visible in PacBio data. B) Example of errors associated with short homopolymer tracts. Multiple insertions are visible in the PacBio Data, deletions are observed in the PGM data and the MiSeq sequences read generally correct through the homopolymer tract. C) Example of strand specific deletions (red circles) observed in Ion Torrent data.CC BY · PubMed Central
Figure 5 Accuracy of SNP detection from the S. aureus datasets generated from each platform, compared against the reference genome of its close relativeS. aureus USA300_FPR3757. Both the Torrent server variant calling pipeline and SAMtools were used for Ion Torrent data; SAMtools was used for Illumina data and SMRT portal pipeline for PacBio data. A) The percentage of SNPs detected using each platform overall (blue bar), and outside of repeats, indels and mobile genetic elements (red bar). B) The number of incorrect SNP calls for each platform overall (blue bar), and outside of repeats, indels and mobile genetic elements (red bar).
Figure 5 Accuracy of SNP detection from the S. aureus datasets generated from each platform, compared against the reference genome of its close relativeS. aureus USA300_FPR3757. Both the Torrent server variant calling pipeline and SAMtools were used for Ion Torrent data; SAMtools was used for Illumina data and SMRT portal pipeline for PacBio data. A) The percentage of SNPs detected using each platform overall (blue bar), and outside of repeats, indels and mobile genetic elements (red bar). B) The number of incorrect SNP calls for each platform overall (blue bar), and outside of repeats, indels and mobile genetic elements (red bar).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 2,031

Metadata

Authors
Quail, M., Smith, M. E., Coupland, P., Otto, T. D., Harris, S. R., Connor, T. R., Bertoni, A., Swerdlow, H. P., & Gu, Y.
Affiliations
Wellcome Sanger Institute (GB)
Corresponding author
Quail, Michael
Venue
BMC Genomics
Published
2012
Volume
13
Issue
1
Pages
341
ISSN
1471-2164 (ISSN-L)
OpenAlex
W2124715997
Cited by
2,031
References
32
Citations by year
2026: 33 · 2025: 50 · 2024: 105 · 2023: 78 · 2022: 91 · 2021: 130 · 2020: 150 · 2019: 144 · 2018: 188 · 2017: 207 · 2016: 254 · 2015: 226 · 2014: 218 · 2013: 144 · 2012: 9
FWCI
76.69
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BMC Genomics (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
  • ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Wellcome Trust (grant number 098051, 098051)
  • European Commission
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Genomics and Rare Diseases
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genetics, Bioinformatics, and Biomedical Research
Keywords
Ion Torrent PGM, Illumina MiSeq, Illumina HiSeq, microbial genomes, AT-rich genome, Plasmodium falciparum, GC content, variant calling, false positive rate, sequencing error rate
MeSH terms
Base Composition, Base Sequence, Bordetella pertussis, Plasmodium falciparum, Staphylococcus aureus, Gene Library, Genome, Bacterial, Sequence Analysis, DNA, Genome, Protozoan, Polymorphism, Single Nucleotide, Databases, Genetic, Nucleotide Motifs

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A tale of three next generation sequencing platforms: comparison of Ion torrent, pacific biosciences and illumina MiSeq sequencers. https://app.cochat.ai/papers/10.1186/1471-2164-13-341
The paper
Quail, M., Smith, M. E., Coupland, P., Otto, T. D., Harris, S. R., Connor, T. R., Bertoni, A., Swerdlow, H. P., & Gu, Y. (2012). A tale of three next generation sequencing platforms: comparison of Ion torrent, pacific biosciences and illumina MiSeq sequencers. BMC Genomics. https://doi.org/10.1186/1471-2164-13-341

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.