i-Tracker: For quantitative proteomics using iTRAQ™
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: iTRAQ™ technology for protein quantitation using mass spectrometry is a recent, powerful means of determining relative protein levels in up to four samples simultaneously. Although protein identification of samples generated using iTRAQ may be carried out using any current identification software, the quantitation calculations have been restricted to the ProQuant software supplied by Applied Biosciences. i-Tracker software has been developed to extract reporter ion peak ratios from non-centroided tandem MS peak lists in a format easily linked to the results of protein identification tools such as Mascot and Sequest. Such functionality is currently not provided by ProQuant, which is restricted to matching quantitative information to the peptide identifications from Applied Biosciences' Interrogator™ software. Results: i-Tracker is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems. Conclusion: i-Tracker allows quantitative information gained using the iTRAQ protocol to be linked with peptide identifications from popular tandem MS identification tools and hence is both a timely and useful tool for the proteomics community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 1×
“However, for the purpose of reporting iTRAQ results it is desirable to verify the proteins identified using a second, more widely used, MSMS search engine such as Mascot [5] or Sequest [6].”
MethodOng, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 5×
“The principal advantage of iTRAQ over ICAT, SILAC and metabolic labelling is that four samples can be analyzed simultaneously, thereby reducing the amount of mass spectrometry time needed for analysis.”
BackgroundInfluentialRoss, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 2×
“iTRAQTM is a recently developed protein quantitation technique that utilizes four isobaric amine specific tags [4].”
MethodMathematical Methods for Physics and Engineering
Riley, K. F., Hobson, M. P., & Bence, S. J. (2006) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810763 · Cited by 923
Metabolic labeling of C. elegans and D. melanogaster for quantitative proteomics
Krijgsveld, J., Ketting, R. F., Mahmoudi, T., Johansen, J., Artal-Sanz, M., Verrijzer, C. P., Plasterk, R. H. A., & Heck, A. J. R. (2003) · Nature Biotechnology · doi:10.1038/nbt848 · Cited by 408
Localization of Organelle Proteins by Isotope Tagging (LOPIT)
Dunkley, T. P. J., Watson, R., Griffin, J. L., Dupree, P., & Lilley, K. S. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400009-mcp200 · Cited by 352
Self-citationExtractor for ESI quadrupole TOF tandem MS data enabled for high throughput batch processing
Boehm, A., Galvin, R. P., & Sickmann, A. (2004) · BMC Bioinformatics · doi:10.1186/1471-2105-5-162 · Cited by 28
Cited by
Proteogenomic Characterization Reveals Therapeutic Vulnerabilities in Lung Adenocarcinoma
Gillette, M. A., Satpathy, S., Cao, S., Dhanasekaran, S. M., Vasaikar, S. V., Krug, K., Petralia, F., Li, Y., Liang, W.-W., Reva, B., et al. (2020) · Cell · doi:10.1016/j.cell.2020.06.013 · Cited by 820
“Relative abundances of proteins and VM-sites were determined in Spectrum Mill using TMT reporter ion intensity ratios from each PSM. TMT reporter ion intensities were corrected for isotopic impurities in the SpectrumMill Protein/Peptide summarymodule using the afRICA correctionmethod, which implements determinant calc…”
MethodIsobaric Labeling-Based Relative Quantification in Shotgun Proteomics
Rauniyar, N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500880b · Cited by 596
Dayon, L., Hainard, A., Licker, V., Turck, N., Kuhn, K., Hochstrasser, D. F., Burkhard, P. R., & Sanchez, J.-C. (2008) · Analytical Chemistry · doi:10.1021/ac702422x · Cited by 561
Proteogenomic Landscape of Breast Cancer Tumorigenesis and Targeted Therapy
Krug, K., Jaehnig, E. J., Satpathy, S., Blumenberg, L., Karpova, A., Anurag, M., Miles, G., Mertins, P., Geffen, Y., Tang, L. C., et al. (2020) · Cell · doi:10.1016/j.cell.2020.10.036 · Cited by 537
Mapping the Arabidopsis organelle proteome
Dunkley, T. P. J., Hester, S., Shadforth, I. P., Runions, J., Weimar, T., Hanton, S. L., Griffin, J. L., Bessant, C., Brandizzi, F., Hawes, C., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0506958103 · Cited by 520
Self-citationNühse, T. S., Bottrill, A. R., Jones, A. M. E., & Peck, S. C. (2007) · The Plant Journal · doi:10.1111/j.1365-313x.2007.03192.x · Cited by 511
Addressing Accuracy and Precision Issues in iTRAQ Quantitation
Karp, N. A., Huber, W., Sadowski, P. G., Charles, P. D., Hester, S. V., & Lilley, K. S. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900628-mcp200 · Cited by 495
Self-citationMertins, P., Tang, L. C., Krug, K., Clark, D. J., Gritsenko, M. A., Chen, L., Clauser, K. R., Clauss, T. R., Shah, P., Gillette, M. A., et al. (2018) · Nature Protocols · doi:10.1038/s41596-018-0006-9 · Cited by 479
Mueller, L. N., Brusniak, M.-Y., Mani, D. R., & Aebersold, R. (2008) · Journal of Proteome Research · doi:10.1021/pr700758r · Cited by 449
A proteogenomic portrait of lung squamous cell carcinoma
Satpathy, S., Krug, K., Jean Beltran, P. M., Savage, S. R., Petralia, F., Kumar-Sinha, C., Dou, Y., Reva, B., Kane, M. H., Avanessian, S. C., et al. (2021) · Cell · doi:10.1016/j.cell.2021.07.016 · Cited by 377
Shotgun proteomics using the iTRAQ isobaric tags
Aggarwal, K. (2006) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/ell018 · Cited by 345
Quantitation in Mass-Spectrometry-Based Proteomics
Schulze, W. X., & Usadel, B. (2010) · Annual Review of Plant Biology · doi:10.1146/annurev-arplant-042809-112132 · Cited by 344
A Curated Resource for Phosphosite-specific Signature Analysis
Krug, K., Mertins, P., Zhang, B., Hornbeck, P., Raju, R., Ahmad, R., Szucs, M., Mundt, F., Forestier, D., Jane-Valbuena, J., et al. (2019) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000943 · Cited by 338
Bioinformatics Methods for Mass Spectrometry-Based Proteomics Data Analysis
Chen, C., Hou, J., Tanner, J. J., & Cheng, J. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082873 · Cited by 280
“There is also a wide range of free software available, including iTracker [78], IsobariQ [77] and Libra [98].”
MethodGrowth control of the eukaryote cell: a systems biology study in yeast
Castrillo, J. I., Zeef, L. A., Hoyle, D. C., Zhang, N., Hayes, A., Gardner, D. C., Cornell, M. J., Petty, J., Hakes, L., Wardleworth, L., et al. (2007) · Journal of Biology · doi:10.1186/jbiol54 · Cited by 263
“iTRAQ reporter ion ratios were calculated from the uncentroided peak lists using i-Tracker [35,128].”
MethodSelf-citationProteomic and phosphoproteomic comparison of human ES and iPS cells
Phanstiel, D. H., Brumbaugh, J., Wenger, C. D., Tian, S., Probasco, M. D., Bailey, D. J., Swaney, D. L., Tervo, M. A., Bolin, J. M., Ruotti, V., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1699 · Cited by 259
A-to-I RNA Editing Contributes to Proteomic Diversity in Cancer
Peng, X., Xu, X., Wang, Y., Hawke, D. H., Yu, S., Han, L., Zhou, Z., Mojumdar, K., Jeong, K. J., Labrie, M., et al. (2018) · Cancer Cell · doi:10.1016/j.ccell.2018.03.026 · Cited by 223
“We employed x-Tracker to extract ion intensity for each peptide identified (Shadforth et al., 2005).”
General Statistical Framework for Quantitative Proteomics by Stable Isotope Labeling
Navarro, P., Trevisan-Herraz, M., Bonzon-Kulichenko, E., Núñez, E., Martínez-Acedo, P., Pérez-Hernández, D., Jorge, I., Mesa, R., Calvo, E., Carrascal, M., et al. (2014) · Journal of Proteome Research · doi:10.1021/pr4006958 · Cited by 217
Reinhardt, T. A., Sacco, R. E., Nonnecke, B. J., & Lippolis, J. D. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.02.013 · Cited by 191
“000,0,0] in all samples according to the algorithm described in i-Tracker [32].”
MethodKeshishian, H., Burgess, M. W., Specht, H., Wallace, L., Clauser, K. R., Gillette, M. A., & Carr, S. A. (2017) · Nature Protocols · doi:10.1038/nprot.2017.054 · Cited by 190
Proteomics of Plant Pathogenic Fungi
González-Fernández, R., Prats, E., & Jorrín-Novo, J. V. (2010) · Journal of Biomedicine and Biotechnology · doi:10.1155/2010/932527 · Cited by 173
“The fragmentation of the attached tag generates a low molecular mass reporter ion that can be used to relatively quantify the peptides and the proteins from which they originated [198].”
BackgroundSmout, M. J., Sotillo, J., Laha, T., Papatpremsiri, A., Rinaldi, G., Pimenta, R. N., Chan, L. Y., Johnson, M. S., Turnbull, L., Whitchurch, C. B., et al. (2015) · PLOS Pathogens · doi:10.1371/journal.ppat.1005209 · Cited by 94
Gene Expression Patterns Associated With Histopathology in Toxic Liver Fibrosis
Ippolito, D. L., AbdulHameed, M. D. M., Tawa, G. J., Baer, C. E., Permenter, M. G., McDyre, B. C., Dennis, W. E., Boyle, M. H., Hobbs, C. A., Streicker, M. A., et al. (2016) · Toxicological Sciences · doi:10.1093/toxsci/kfv214 · Cited by 43
Metadata
- Authors
- Shadforth, I. P., Dunkley, T. P., Lilley, K. S., & Bessant, C.
- Venue
- BMC Genomics
- Published
- 2005-10-20
- Volume
- 6
- Issue
- 1
- Pages
- 145-145
- ISSN
- 1471-2164 (ISSN-L)
- OpenAlex
- W1583738858
- Cited by
- 281
- References
- 9
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.