Standardization of cytokine flow cytometry assays
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background: Cytokine flow cytometry (CFC) or intracellular cytokine staining (ICS) can quantitate antigen-specific T cell responses in settings such as experimental vaccination. Standardization of ICS among laboratories performing vaccine studies would provide a common platform by which to compare the immunogenicity of different vaccine candidates across multiple international organizations conducting clinical trials. As such, a study was carried out among several laboratories involved in HIV clinical trials, to define the inter-lab precision of ICS using various sample types, and using a common protocol for each experiment (see additional files online). Results: Three sample types (activated, fixed, and frozen whole blood; fresh whole blood; and cryopreserved PBMC) were shipped to various sites, where ICS assays using cytomegalovirus (CMV) pp65 peptide mix or control antigens were performed in parallel in 96-well plates. For one experiment, antigens and antibody cocktails were lyophilised into 96-well plates to simplify and standardize the assay setup. Results (CD4+cytokine+ cells and CD8+cytokine+ cells) were determined by each site. Raw data were also sent to a central site for batch analysis with a dynamic gating template. Mean inter-laboratory coefficient of variation (C.V.) ranged from 17–44% depending upon the sample type and analysis method. Cryopreserved peripheral blood mononuclear cells (PBMC) yielded lower inter-lab C.V.'s than whole blood. Centralized analysis (using a dynamic gating template) reduced the inter-lab C.V. by 5–20%, depending upon the experiment. The inter-lab C.V. was lowest (18–24%) for samples with a mean of >0.5% IFNγ + T cells, and highest (57–82%) for samples with a mean of <0.1% IFNγ + cells. Conclusion: ICS assays can be performed by multiple laboratories using a common protocol with good inter-laboratory precision, which improves as the frequency of responding cells increases. Cryopreserved PBMC may yield slightly more consistent results than shipped whole blood. Analysis, particularly gating, is a significant source of variability, and can be reduced by centralized analysis and/or use of a standardized dynamic gating template. Use of pre-aliquoted lyophilized reagents for stimulation and staining can provide further standardization to these assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Funnekotter, B. (2005) · Eureka! · doi:10.1017/9789048505418.012 · Cited by 1,666
Brown, R. A., & Motulsky, H. (1997) · Biometrics · doi:10.2307/2533525 · Cited by 800
Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective
Findlay, J. W. A., Smith, W. C., Lee, J. W., Nordblom, G. D., Das, I., DeSilva, B. S., Khan, M. N., & Bowsher, R. R. (2000) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(99)00244-7 · Cited by 589 · cited 1×
“ICS is also comparable to cytokine ELISA, the latter having reported interassay C.V.'s of 32 ].”
MethodPantaleo, G., & Koup, R. A. (2004) · Nature Medicine · doi:10.1038/nm0804-806 · Cited by 444 · cited 1×
“While most current HIV trials are not powered to determine efficacy, and cytokine production has not been validated as a surrogate marker of protection from HIV infection or progression, there is nevertheless a desire to measure immunogenicity of candidate vaccines as well as safety in early clinical trials [5].”
BackgroundSelf-citationUse of overlapping peptide mixtures as antigens for cytokine flow cytometry
Maecker, H. T., Dunn, H. S., Suni, M. A., Khatamzas, E., Pitcher, C. J., Bunde, T., Persaud, N., Trigona, W., Fu, T.-M., Sinclair, E., et al. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00416-1 · Cited by 356 · cited 1×
“Cryopreserved PBMC are much more amenable to peptide (and superantigen) stimulation than to whole protein stimulation [9]; while whole blood assays are equally amenable to stimulation with either type of antigen.”
Self-citation(1972) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/49.1.119 · Cited by 351
Currier, J. R., Kuta, E. G., Turk, E., Earhart, L. B., Loomis-Price, L., Janetzki, S., Ferrari, G., Birx, D. L., & Cox, J. H. (2002) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00535-x · Cited by 320 · cited 5×
“Cytokine-positive cells in response to CEF peptides or CMV pp65 peptide mix are expressed as a percentage of CD4 + or CD8 + T cells.”
InfluentialSelf-citationKern, F., Bunde, T., Faulhaber, N., Kiecker, F., Khatamzas, E., Rudawski, I., Pruss, A., Gratama, J., Volkmer‐Engert, R., Ewert, R., et al. (2002) · The Journal of Infectious Diseases · doi:10.1086/340637 · Cited by 277 · cited 1×
“The blood was incubated for 6 hours in the presence of brefeldin A, either with no stimulus, Staphylococcal enterotoxin B (SEB), or a mixture of overlapping peptides corresponding to the CMV pp65 protein [8-10].”
McMichael, A. J., & Hanke, T. (2003) · Nature Medicine · doi:10.1038/nm0703-874 · Cited by 240 · cited 1×
“Numerous phase I and phase II clinical trials have been initiated using candidate prophylactic HIV vaccines (reviewed in [4]).”
BackgroundKarlsson, A. C., Martin, J. N., Younger, S. R., Bredt, B. M., Epling, L., Ronquillo, R., Varma, A., Deeks, S. G., McCune, J. M., Nixon, D. F., et al. (2003) · Journal of Immunological Methods · doi:10.1016/j.jim.2003.09.001 · Cited by 223 · cited 1×
“have been published [15-21].”
Self-citation
Cited by
Standardizing immunophenotyping for the Human Immunology Project
Maecker, H. T., McCoy, J. P., & Nussenblatt, R. (2012) · Nature Reviews Immunology · doi:10.1038/nri3158 · Cited by 1,176
Self-citationVariation in the Human Immune System Is Largely Driven by Non-Heritable Influences
Brodin, P., Jojic, V., Gao, T., Bhattacharya, S., Angel, C. J. L., Furman, D., Shen-Orr, S., Dekker, C. L., Swan, G. E., Butte, A. J., et al. (2015) · Cell · doi:10.1016/j.cell.2014.12.020 · Cited by 1,065
“Immunological assays were performed by the Human Immune Monitoring Center, where assays are continually benchmarked to minimize technical variability (http://iti.stanford.edu/himc/) (Maecker et al., 2005).”
MethodSelf-citationGuidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationCritical assessment of automated flow cytometry data analysis techniques
The FlowCAP Consortium, Aghaeepour, N., The DREAM Consortium, Finak, G., Hoos, H., Mosmann, T. R., Brinkman, R., Gottardo, R., & Scheuermann, R. H. (2013) · Nature Methods · doi:10.1038/nmeth.2365 · Cited by 598
flowCore: a Bioconductor package for high throughput flow cytometry
Hahne, F., LeMeur, N., Brinkman, R. R., Ellis, B., Haaland, P., Sarkar, D., Spidlen, J., Strain, E., & Gentleman, R. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-106 · Cited by 581
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Self-citationMIFlowCyt: The minimum information about a flow cytometry experiment
Lee, J. A., Spidlen, J., Boyce, K., Cai, J., Crosbie, N., Dalphin, M., Furlong, J., Gasparetto, M., Goldberg, M., Goralczyk, E. M., et al. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20623 · Cited by 533
“of existing FCM data because of poor annotation (2).”
BackgroundGuidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
Automated identification of stratifying signatures in cellular subpopulations
Bruggner, R. V., Bodenmiller, B., Dill, D. L., Tibshirani, R. J., & Nolan, G. P. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1408792111 · Cited by 473
Neonatal Innate TLR-Mediated Responses Are Distinct from Those of Adults
Kollmann, T. R., Crabtree, J., Rein-Weston, A., Blimkie, D., Thommai, F., Wang, X. Y., Lavoie, P. M., Furlong, J., Fortuno, E. S., Hajjar, A. M., et al. (2009) · The Journal of Immunology · doi:10.4049/jimmunol.0901481 · Cited by 466
Flow cytometry controls, instrument setup, and the determination of positivity
Maecker, H. T., & Trotter, J. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20333 · Cited by 366
Self-citationStandardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium
Finak, G., Langweiler, M., Jaimes, M., Malek, M., Taghiyar, J., Korin, Y., Raddassi, K., Devine, L., Obermoser, G., Pekalski, M. L., et al. (2016) · Scientific Reports · doi:10.1038/srep20686 · Cited by 285
Self-citationIntracellular cytokine optimization and standard operating procedure
Lamoreaux, L., Roederer, M., & Koup, R. (2006) · Nature Protocols · doi:10.1038/nprot.2006.268 · Cited by 268
“Basic ICS procedures have been described previously in the literature, but our assay uniquely focuses on the detection of low-frequency cell populations, which may be responsible for protective immunity in vaccine trial”
MethodSelf-citationHorton, H., Thomas, E. P., Stucky, J. A., Frank, I., Moodie, Z., Huang, Y., Chiu, Y.-L., McElrath, M. J., & De Rosa, S. C. (2007) · Journal of Immunological Methods · doi:10.1016/j.jim.2007.03.002 · Cited by 258
Self-citationBrignone, C., Escudier, B., Grygar, C., Marcu, M., & Triebel, F. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-0068 · Cited by 226
“Statistical tests were used to determine whether a given response obtained on day 85 (D85) can be discriminated from a given background at baseline, using the formula power calculation as follows (17):”
MethodPerfetto, S. P., Chattopadhyay, P. K., Lamoreaux, L., Nguyen, R., Ambrozak, D., Koup, R. A., & Roederer, M. (2006) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.04.007 · Cited by 223
Self-citationFinak, G., Frelinger, J., Jiang, W., Newell, E. W., Ramey, J., Davis, M. M., Kalams, S. A., De Rosa, S. C., & Gottardo, R. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003806 · Cited by 197
“The subjectivity of manual gating introduces variability into the data and significantly impacts the reproducibility, robustness and comparability of results, particularly in multi-center trials [7,8].”
BackgroundFunctional signatures in antiviral T-cell immunity for monitoring virus-associated diseases
Pantaleo, G., & Harari, A. (2006) · Nature Reviews Immunology · doi:10.1038/nri1840 · Cited by 196
“Second, there is a lack of reliable, standardized quantitative assays of T-cell function, and the T-cell assays that are available are time consuming (requiring 1 to 6 days) and are not automate”
Self-citationWeinberg, A., Song, L.-Y., Wilkening, C., Sevin, A., Blais, B., Louzao, R., Stein, D., Defechereux, P., Durand, D., Riedel, E., et al. (2009) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00342-08 · Cited by 194
“Assays have to be adapted and validated for the use of cryopreserved PBMC (4, 6, 9, 11, 17, 19), and the quality of the frozen cells has to be monitored (5) to ensure reliable results in functional and phenotypic assays.”
MethodEzzelle, J., Rodriguez-Chavez, I. R., Darden, J. M., Stirewalt, M., Kunwar, N., Hitchcock, R., Walter, T., & D'Souza, M. P. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.10.010 · Cited by 172
Self-citationOntogeny of Toll-Like Receptor Mediated Cytokine Responses of Human Blood Mononuclear Cells
Corbett, N. P., Blimkie, D., Ho, K. C., Cai, B., Sutherland, D. P., Kallos, A., Crabtree, J., Rein-Weston, A., Lavoie, P. M., Turvey, S. E., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015041 · Cited by 170
“Compensation beads (CompBeads; BD Biosciences) were used to standardize voltage settings and used as single-stain positive and negative controls as described previously [9,11,31].”
MethodDetection of Intracellular Cytokines by Flow Cytometry
Yin, Y., Mitson‐Salazar, A., & Prussin, C. (2015) · Current Protocols in Immunology · doi:10.1002/0471142735.im0624s110 · Cited by 162
“Indeed, ICCS has emerged as a major platform to for multicenter vaccine and viral immunology studies (Maecker et al., 2005; Lamoreaux et al., 2006).”
BackgroundA model for harmonizing flow cytometry in clinical trials
the FOCIS Human Immunophenotyping Consortium, Maecker, H. T., & McCoy, J. P. (2010) · Nature Immunology · doi:10.1038/ni1110-975 · Cited by 155
Self-citationMethods to quantify biological contaminants in microalgae cultures
Di Caprio, F. (2020) · Algal Research · doi:10.1016/j.algal.2020.101943 · Cited by 87
Ivison, S., Malek, M., Garcia, R. V., Broady, R., Halpin, A., Richaud, M., Brant, R. F., Wang, S.-I., Goupil, M., Guan, Q., et al. (2018) · JCI Insight · doi:10.1172/jci.insight.121867 · Cited by 49
Metadata
- Authors
- Maecker, H. T., Rinfret, A., D'Souza, P., Darden, J., Roig, E., Landry, C., Hayes, P., Birungi, J., Anzala, O., Garcia, M., Harari, A., Frank, I., Baydo, R., Baker, M., Holbrook, J., Ottinger, J., Lamoreaux, L., Epling, C. L., Sinclair, E., Suni, M. A., Punt, K., Calarota, S., El-Bahi, S., Alter, G., Maila, H., Kuta, E., Cox, J., Gray, C., Altfeld, M., Nougarede, N., Boyer, J., Tussey, L., Tobery, T., Bredt, B., Roederer, M., Koup, R., Maino, V. C., Weinhold, K., Pantaleo, G., Gilmour, J., Horton, H., & Sekaly, R. P.
- Venue
- BMC Immunology
- Published
- 2005-06-24
- Volume
- 6
- Issue
- 1
- Pages
- 13-13
- ISSN
- 1471-2172 (ISSN-L)
- OpenAlex
- W1941148137
- Cited by
- 241
- References
- 30
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.