CoChat

Nasal high–flow oxygen therapy in patients with hypoxic respiratory failure: effect on functional and subjective respiratory parameters compared to conventional oxygen therapy and non-invasive ventilation (NIV)

Open access
Schwabbauer, Norbert, Berg, Björn, Blumenstock, Gunnar, Haap, Michael, Hetzel, Jürgen, Riessen, Reimer · 2014 · BMC Anesthesiology
Cited by 167

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Aim of the study was to compare the short-term effects of oxygen therapy via a high-flow nasal cannula (HFNC) on functional and subjective respiratory parameters in patients with acute hypoxic respiratory failure in comparison to non-invasive ventilation (NIV) and standard treatment via a Venturi mask. METHODS: Fourteen patients with acute hypoxic respiratory failure were treated with HFNC (FiO2 0.6, gas flow 55 l/min), NIV (FiO2 0.6, PEEP 5 cm H2O Hg, tidal volume 6-8 ml/kg ideal body weight,) and Venturi mask (FiO2 0.6, oxygen flow 15 l/min,) in a randomized order for 30 min each. Data collection included objective respiratory and circulatory parameters as well as a subjective rating of dyspnea and discomfort by the patients on a 10-point scale. In a final interview, all three methods were comparatively evaluated by each patient using a scale from 1 (=very good) to 6 (=failed) and the patients were asked to choose one method for further treatment. RESULTS: PaO2 was highest under NIV (129 ± 38 mmHg) compared to HFNC (101 ± 34 mmHg, p <0.01 vs. NIV) and VM (85 ± 21 mmHg, p <0.001 vs. NIV, p <0.01 vs. HFNC, ANOVA). All other functional parameters showed no relevant differences. In contrast, dyspnea was significantly better using a HFNC (2.9 ± 2.1, 10-point Borg scale) compared to NIV (5.0 ± 3.3, p <0.05), whereas dyspnea rating under HFNC and VM (3.3 ± 2.3) was not significantly different. A similar pattern was found when patients rated their overall discomfort on the 10 point scale: HFNC 2.7 ± 1.8, VM 3.1 ± 2.8 (ns vs. HFNC), NIV 5.4 ± 3.1 (p <0.05 vs. HFNC). In the final evaluation patients gave the best ratings to HFNC 2.3 ± 1.4, followed by VM 3.2 ± 1.7 (ns vs. HFNC) and NIV 4.5 ± 1.7 (p <0.01 vs. HFNC and p <0.05 vs. VM). For further treatment 10 patients chose HFNC, three VM and one NIV. CONCLUSIONS: In hypoxic respiratory failure HFNC offers a good balance between oxygenation and comfort compared to NIV and Venturi mask and seems to be well tolerated by patients. TRIAL REGISTRATION: GERMAN CLINICAL TRIALS REGISTER: DRKS00005132.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2253-14-66

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Schwabbauer, N., Berg, B., Blumenstock, G., Haap, M., Hetzel, J., & Riessen, R.
Venue
BMC Anesthesiology
Published
2014-08-07
Volume
14
Issue
1
Pages
66-66
ISSN
1471-2253 (ISSN-L)
OpenAlex
W2131662900
Cited by
167
References
23
FWCI
10.66
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.