Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Electronic monitoring (EM) is used increasingly to measure medication non-adherence. Unbiased EM assessment requires fulfillment of assumptions. The purpose of this study was to determine assumptions needed for internal and external validity of EM measurement. To test internal validity, we examined if (1) EM equipment functioned correctly, (2) if all EM bottle openings corresponded to actual drug intake, and (3) if EM did not influence a patient's normal adherence behavior. To assess external validity, we examined if there were indications that using EM affected the sample representativeness. METHODS: We used data from the Supporting Medication Adherence in Renal Transplantation (SMART) study, which included 250 adult renal transplant patients whose adherence to immunosuppressive drugs was measured during 3 months with the Medication Event Monitoring System (MEMS). Internal validity was determined by assessing the prevalence of nonfunctioning EM systems, the prevalence of patient-reported discrepancies between cap openings and actual intakes (using contemporaneous notes and interview at the end of the study), and by exploring whether adherence was initially uncharacteristically high and decreased over time (an indication of a possible EM intervention effect). Sample representativeness was examined by screening for differences between participants and non-participants or drop outs on non-adherence. RESULTS: Our analysis revealed that some assumptions were not fulfilled: 1) one cap malfunctioned (0.4%), 2) self-reported mismatches between bottle openings and actual drug intake occurred in 62% of the patients (n = 155), and 3) adherence decreased over the first 5 weeks of the monitoring, indicating that EM had a waning intervention effect. CONCLUSION: The validity assumptions presented in this article should be checked in future studies using EM as a measure of medication non-adherence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osterberg, L., & Blaschke, T. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050100 · Cited by 7,974
Denhaerynck, K., Steiger, J., Bock, A., Schäfer-Keller, P., Köfer, S., Thannberger, N., & De Geest, S. (2007) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2006.01611.x · Cited by 184
Self-citationComparing compliance patterns between randomized treatments
Vrijens, B., & Goetghebeur, E. (1997) · Controlled Clinical Trials · doi:10.1016/s0197-2456(96)00235-8 · Cited by 114
Cited by
Dobbels, F., Ruppar, T., De Geest, S., Decorte, A., Van Damme-Lombaerts, R., & Fine, R. N. (2009) · Pediatric Transplantation · doi:10.1111/j.1399-3046.2010.01299.x · Cited by 305
Self-citationDobbels, F., Berben, L., De Geest, S., Drent, G., Lennerling, A., Whittaker, C., & Kugler, C. (2010) · Transplantation · doi:10.1097/tp.0b013e3181e346cd · Cited by 220
Schäfer-Keller, P., Steiger, J., Bock, A., Denhaerynck, K., & De Geest, S. (2008) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2007.02127.x · Cited by 198
Self-citationA Proposal for Quality Standards for Measuring Medication Adherence in Research
Williams, A. B., Amico, K. R., Bova, C., & Womack, J. A. (2013) · AIDS and Behavior · doi:10.1007/s10461-012-0172-7 · Cited by 198
De Bleser, L., Dobbels, F., Berben, L., Vanhaecke, J., Verleden, G., Nevens, F., & De Geest, S. (2011) · Transplant International · doi:10.1111/j.1432-2277.2011.01296.x · Cited by 89
Metadata
- Authors
- Denhaerynck, K., Schäfer-Keller, P., Young, J., Steiger, J., Bock, A., & De Geest, S.
- Venue
- BMC Medical Research Methodology
- Published
- 2008-02-19
- Volume
- 8
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1471-2288 (ISSN-L)
- OpenAlex
- W2009138410
- Cited by
- 91
- References
- 3
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients. https://app.cochat.ai/papers/10.1186/1471-2288-8-5
- The paper
- Denhaerynck, K., Schäfer-Keller, P., Young, J., Steiger, J., Bock, A., & De Geest, S. (2008). Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients. BMC Medical Research Methodology. https://doi.org/10.1186/1471-2288-8-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.