The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care
Open accessThe DOI matches its Crossref record; 21 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Atrial fibrillation is very common in people aged 65 or older. This condition increases the risk of death, congestive heart failure and thromboembolic conditions. Many patients with atrial fibrillation are asymptomatic and a cerebrovascular accident (CVA) is often the first clinical presentation. Guidelines concerning the prevention of CVA recommend monitoring the heart rate in patients aged 65 or older. Recently, the MyDiagnostick (Applied Biomedical Systems BV, Maastricht, The Netherlands) was introduced as a new screening tool which might serve as an alternative for the less accurate pulse palpation. This study was designed to explore the diagnostic accuracy of the MyDiagnostick for the detection of atrial fibrillation. METHODS: A phase II diagnostic accuracy study in a convenience sample of 191 subjects recruited in primary care. The majority of participants were patients with a known history of atrial fibrillation (n=161). Readings of the MyDiagnostick were compared with electrocardiographic recordings. Sensitivity and specificity and their 95% confidence interval were calculated using 2x2 tables. RESULTS: A prevalence of 54% for an atrial fibrillation rhythm was found in the study population at the moment of the study. A combination of three measurements with the MyDiagnostick for each patient showed a sensitivity of 94% (95% CI 87 - 98) and a specificity of 93% (95% CI 85 - 97). CONCLUSION: The MyDiagnostick is an easy-to-use device that showed a good diagnostic accuracy with a high sensitivity and specificity for atrial fibrillation in a convenience sample in primary care. Future research is needed to determine the place of the MyDiagnostick in possible screening or case-finding strategies for atrial fibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879 · cited 1×
“In order to assess this risk, the CHADS2 score is used, along with the more recent and more accurate CHA2DS2VASc score [7,8].”
MethodGage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
Principles and Practice of Screening for Disease.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-5-1085_2 · Cited by 3,066 · cited 1×
“atrial fibrillation is a condition for which screening can or should be done [9].”
Background2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Wang, T. J., Larson, M. G., Levy, D., Vasan, R. S., Leip, E. P., Wolf, P. A., D’Agostino, R. B., Murabito, J. M., Kannel, W. B., & Benjamin, E. J. (2003) · Circulation · doi:10.1161/01.cir.0000072767.89944.6e · Cited by 1,970 · cited 1×
“Furthermore, this condition increases the risk of death, congestive heart failure and thromboembolic conditions [2,3].”
BackgroundPrinciples and Practice of Screening for Disease.
Zavon, M. R. (1969) · Archives of Internal Medicine · doi:10.1001/archinte.1969.00300130131020 · Cited by 1,356
Prineas, R. J., Crow, R. S., & BLACKBURN, H. W. (1982) · Cited by 701
The Minnesota Code Manual of Electrocardiographic Findings
Prineas, R. J., Crow, R. S., & Zhang, Z.-M. (2010) · Springer eBooks · doi:10.1007/978-1-84882-778-3 · Cited by 563
Minnesota Code Manual of Electrocardiographic Findings
Marty, A. T. (1983) · Critical Care Medicine · doi:10.1097/00003246-198307000-00029 · Cited by 310 · cited 2×
“The ECGs were analyzed off-line on the basis of the Minnesota Code Classification System for Electrocardiographic Findings [14] (code 8-3-1) by an experienced cardiologist (WM), blinded for the software interpretation and the results from the MyDiagnostick.”
MethodAtrial fibrillation: classification, pathophysiology, mechanisms and drug treatment
Markides, V., & Schilling, R. J. (2003) · Heart · doi:10.1136/heart.89.8.939 · Cited by 244 · cited 1×
“9% in patients between 70 – 79 years to 24% in the group of patients between 80 – 89 years [4-6].”
BackgroundNieuwlaat, R., Olsson, S. B., Lip, G. Y. H., Camm, A. J., Breithardt, G., Capucci, A., Meeder, J. G., Prins, M. H., Lévy, S., & Crijns, H. J. G. M. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.03.008 · Cited by 208
Mant, J., Fitzmaurice, D. A., Hobbs, F. D. R., Jowett, S., Murray, E. T., Holder, R., Davies, M., & Lip, G. Y. H. (2007) · BMJ · doi:10.1136/bmj.39227.551713.ae · Cited by 166 · cited 2×
“found a sensitivity of 85% (95% CI 79 – 91) and a specificity of 86% (95% CI 85 – 88) with the use of a thoracic lead and a sensitivity of 83% (95% CI 75 – 89) and a specificity of 89% (95% CI 87 – 90) with the use of a peripheral lead [19].”
BackgroundResultSimple nomograms to calculate sample size in diagnostic studies
Carley, S. (2005) · Emergency Medicine Journal · doi:10.1136/emj.2003.011148 · Cited by 130 · cited 1×
“05), an estimated prevalence of atrial fibrillation of 50% in the study population, an expected sensitivity and specificity of 95% and a confidence interval of 4%, a sample size of 160 subjects was needed [13].”
BackgroundDetection of Atrial Fibrillation Using a Modified Microlife Blood Pressure Monitor
Wiesel, J., Fitzig, L., Herschman, Y., & Messineo, F. C. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2009.98 · Cited by 120 · cited 1×
“The Microlife BP monitor (Microlife Corporation, Taipei, Taiwan), a modified sphygmomanometer that records pulse intervals, gave a sensitivity of 100% and a specificity of 90% (95% CI 87 – 92) when multiple measurements were carried out [16].”
BackgroundRandomised trial of two approaches to screening for atrial fibrillation in UK general practice.
Morgan, S., & Mant, D. (2002) · Europe PMC (PubMed Central) · Cited by 100
Coronary Ischemic Events after First Atrial Fibrillation: Risk and Survival
Miyasaka, Y., Barnes, M. E., Gersh, B. J., Cha, S. S., Bailey, K. R., Seward, J. B., Iwasaka, T., & Tsang, T. S. M. (2007) · The American Journal of Medicine · doi:10.1016/j.amjmed.2006.06.042 · Cited by 79 · cited 1×
“Furthermore, this condition increases the risk of death, congestive heart failure and thromboembolic conditions [2,3].”
BackgroundHow can we best detect atrial fibrillation?
Harris, K., Edwards, D., & Mant, J. (2012) · PubMed · doi:10.4997/jrcpe.2012.s02 · Cited by 61 · cited 2×
“Palpation of the pulse, to monitor the heart rate, has a good sensitivity but a low specificity, making this a useful method of ruling out atrial fibrillation but a less good method of confirming it [11].”
BackgroundMethodWiesel, J., Abraham, S., & Messineo, F. C. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.01.331 · Cited by 58 · cited 1×
“Pulse palpation to detect an irregular heartbeat gave a high sensitivity (87% – 97%) but a moderate to low specificity (71% – 81%) [11,15].”
BackgroundAtrial fibrillation: a comparison of methods to identify cases in general practice.
Somerville, S., Somerville, J., Croft, P. R., & Lewis, M. (2000) · Europe PMC (PubMed Central) · Cited by 56
Screening for atrial fibrillation: sensitivity and specificity of a new methodology
Lewis, M., Parker, D., Weston, C., & Bowes, M. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x548956 · Cited by 41 · cited 1×
“A finger probe that registered a pulse wave pattern for 30 seconds gave a sensitivity of 100% and a specificity of 91% [18].”
BackgroundProphylactic treatment of migraine; the patient's view, a qualitative study
Dekker, F., Neven, A. K., Andriesse, B., Kernick, D. P., Reis, R., Ferrari, M. D., & Assendelft, W. J. (2012) · BMC Family Practice · doi:10.1186/1471-2296-13-13 · Cited by 32
Collaborative Group DOFA-AP, Pérula-de-Torres, L., Martínez-Adell, M., González-Blanco, V., Baena-Díez, J. M., Martín-Rioboó, E., Rejano, J. M. P., González-Lama, J., Álvarez, R. M., Moral, R. R., et al. (2012) · BMC Family Practice · doi:10.1186/1471-2296-13-106 · Cited by 18
Cited by
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H. (2016) · Europace · doi:10.1093/europace/euw025 · Cited by 164
“9%) in other trials when compared with that of a simultaneous 12-lead ECG recording.(10,11) Most other studies screened less patients, probably in more controlled populations and conditions, e.”
ResultAronsson, M., Svennberg, E., Rosenqvist, M., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman-Kull, V., & Levin, L.-Å. (2015) · Europace · doi:10.1093/europace/euv083 · Cited by 154
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis
Welton, N. J., McAleenan, A., Thom, H. H., Davies, P., Hollingworth, W., Higgins, J. P., Okoli, G., Sterne, J. A., Feder, G., Eaton, D., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21290 · Cited by 141
“Applicability: patient selection Only those studies performed in primary care were judged to have a low level of concern with regard to applicability.(19,67,70,72) Applicability: index test Studies in which the index test was interpreted by a cardiologist were judged to be less applicable (high level of concern regard…”
BackgroundMethodInfluential
Metadata
- Authors
- Vaes, B., Stalpaert, S., Tavernier, K., Thaels, B., Lapeire, D., Mullens, W., & Degryse, J.
- Affiliations
- UCLouvain (BE)
- KU Leuven (BE)
- Corresponding author
- Vaes, Bert
- ORCID
- Vaes, Bert
- Venue
- BMC Family Practice
- Published
- 2014-06-09
- Volume
- 15
- Issue
- 1
- Pages
- 113-113
- ISSN
- 1471-2296 (ISSN-L)
- PMC
- PMC4069340
- OpenAlex
- W2107017489
- Semantic Scholar
- 877abe3429c58cbca56dd4d6a5a1bfa8648e0a5f
- Cited by
- 81
- References
- 24
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 12 · 2020: 11 · 2019: 6 · 2018: 7 · 2017: 9 · 2016: 5 · 2015: 3
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMC Family Practice (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Lirias (submittedVersion, cc-by)
- DIAL (Catholic University of Leuven) (submittedVersion, other-oa)
- Document Server@UHasselt (UHasselt) (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Health Promotion and Cardiovascular Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, pulse rate monitoring, diagnostic accuracy, screening, primary care, electrocardiogram, stroke prevention, older adults, case finding
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Diagnosis, Differential, Electrocardiography, Female, Humans, Male, Middle Aged, Primary Health Care, Sensitivity and Specificity, Prevalence, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.