The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care
Open accessThe DOI matches its Crossref record; 21 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Atrial fibrillation is very common in people aged 65 or older. This condition increases the risk of death, congestive heart failure and thromboembolic conditions. Many patients with atrial fibrillation are asymptomatic and a cerebrovascular accident (CVA) is often the first clinical presentation. Guidelines concerning the prevention of CVA recommend monitoring the heart rate in patients aged 65 or older. Recently, the MyDiagnostick (Applied Biomedical Systems BV, Maastricht, The Netherlands) was introduced as a new screening tool which might serve as an alternative for the less accurate pulse palpation. This study was designed to explore the diagnostic accuracy of the MyDiagnostick for the detection of atrial fibrillation. METHODS: A phase II diagnostic accuracy study in a convenience sample of 191 subjects recruited in primary care. The majority of participants were patients with a known history of atrial fibrillation (n=161). Readings of the MyDiagnostick were compared with electrocardiographic recordings. Sensitivity and specificity and their 95% confidence interval were calculated using 2x2 tables. RESULTS: A prevalence of 54% for an atrial fibrillation rhythm was found in the study population at the moment of the study. A combination of three measurements with the MyDiagnostick for each patient showed a sensitivity of 94% (95% CI 87 - 98) and a specificity of 93% (95% CI 85 - 97). CONCLUSION: The MyDiagnostick is an easy-to-use device that showed a good diagnostic accuracy with a high sensitivity and specificity for atrial fibrillation in a convenience sample in primary care. Future research is needed to determine the place of the MyDiagnostick in possible screening or case-finding strategies for atrial fibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879 · cited 1×
“In order to assess this risk, the CHADS2 score is used, along with the more recent and more accurate CHA2DS2VASc score [7,8].”
MethodGage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
Principles and Practice of Screening for Disease.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-5-1085_2 · Cited by 3,066 · cited 1×
“atrial fibrillation is a condition for which screening can or should be done [9].”
Background2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Wang, T. J., Larson, M. G., Levy, D., Vasan, R. S., Leip, E. P., Wolf, P. A., D’Agostino, R. B., Murabito, J. M., Kannel, W. B., & Benjamin, E. J. (2003) · Circulation · doi:10.1161/01.cir.0000072767.89944.6e · Cited by 1,970 · cited 1×
“Furthermore, this condition increases the risk of death, congestive heart failure and thromboembolic conditions [2,3].”
BackgroundPrinciples and Practice of Screening for Disease.
Zavon, M. R. (1969) · Archives of Internal Medicine · doi:10.1001/archinte.1969.00300130131020 · Cited by 1,356
Prineas, R. J., Crow, R. S., & BLACKBURN, H. W. (1982) · Cited by 701
The Minnesota Code Manual of Electrocardiographic Findings
Prineas, R. J., Crow, R. S., & Zhang, Z.-M. (2010) · Springer eBooks · doi:10.1007/978-1-84882-778-3 · Cited by 563
Minnesota Code Manual of Electrocardiographic Findings
Marty, A. T. (1983) · Critical Care Medicine · doi:10.1097/00003246-198307000-00029 · Cited by 310 · cited 2×
“The ECGs were analyzed off-line on the basis of the Minnesota Code Classification System for Electrocardiographic Findings [14] (code 8-3-1) by an experienced cardiologist (WM), blinded for the software interpretation and the results from the MyDiagnostick.”
Method
Cited by
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H. (2016) · Europace · doi:10.1093/europace/euw025 · Cited by 164
“9%) in other trials when compared with that of a simultaneous 12-lead ECG recording.(10,11) Most other studies screened less patients, probably in more controlled populations and conditions, e.”
ResultAronsson, M., Svennberg, E., Rosenqvist, M., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman-Kull, V., & Levin, L.-Å. (2015) · Europace · doi:10.1093/europace/euv083 · Cited by 154
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis
Welton, N. J., McAleenan, A., Thom, H. H., Davies, P., Hollingworth, W., Higgins, J. P., Okoli, G., Sterne, J. A., Feder, G., Eaton, D., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21290 · Cited by 141
“Applicability: patient selection Only those studies performed in primary care were judged to have a low level of concern with regard to applicability.(19,67,70,72) Applicability: index test Studies in which the index test was interpreted by a cardiologist were judged to be less applicable (high level of concern regard…”
BackgroundMethodInfluentialKotecha, D., BREITHARDT, G. E., Camm, A. J., Lip, G. Y. H., Schotten, U., Ahlsson, A., Arnar, D. O., Atar, D., Auricchio, A., Bax, J. J., et al. (2018) · EP Europace · doi:10.1093/europace/eux318 · Cited by 126
Taggar, J. S., Coleman, T., Lewis, S., Heneghan, C., & Jones, M. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487315611347 · Cited by 105
“Although the majority of studies avoided a case– controlled design, only four were prospective and seven studies were conducted in a primary care setting.(9,25,27,30,32,34,35) AF prevalence ranged from 5.”
BackgroundMobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77
“Only two studies provided the calculation of the sample size.(25,37) Seven studies (22%) were at low risk of bias.”
BackgroundEmerging Technologies for Identifying Atrial Fibrillation
Ding, E., Marcus, G. M., & McManus, D. D. (2020) · Circulation Research · doi:10.1161/circresaha.119.316342 · Cited by 87
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Approaches of wearable and implantable biosensor towards of developing in precision medicine
Ghazizadeh, E., Naseri, Z., Deigner, H.-P., Rahimi, H., & Altıntaş, Z. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1390634 · Cited by 91
How will machine learning inform the clinical care of atrial fibrillation?
Siontis, K. C., Yao, X., Pirruccello, J. P., Philippakis, A. A., & Noseworthy, P. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316401 · Cited by 61
FrWT-PPCA-Based R-peak Detection for Improved Management of Healthcare System
Gupta, V., Mittal, M., & Mittal, V. (2021) · IETE Journal of Research · doi:10.1080/03772063.2021.1982412 · Cited by 69
Kaasenbrood, F., Hollander, M., de Bruijn, S. H., Dolmans, C. P., Tieleman, R. G., Hoes, A. W., & Rutten, F. H. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x708161 · Cited by 62
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Ding, E., Han, D., Whitcomb, C., Bashar, S. K., Adaramola, O., Soni, A., Saczynski, J. S., Fitzgibbons, T. P., Moonis, M., Lubitz, S. A., et al. (2019) · JMIR Cardio · doi:10.2196/13850 · Cited by 59
“This is distinct from AliveCor’s Kardia device and other commercial ECG-based devices, such as the MyDiagnostick [39] and Zenicor [40] products, which have no passive monitoring component.”
MethodVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12795 · Cited by 54
Wong, K. C., Klimis, H., Lowres, N., Huben, A. V., Marschner, S. L., & Chow, C. K. (2020) · Heart · doi:10.1136/heartjnl-2020-316611 · Cited by 51
2021 Asia Pacific Heart Rhythm Society (APHRS) practice guidance on atrial fibrillation screening
Chan, N., Orchard, J. J., Agbayani, M. F., Boddington, D., Chao, T., Johar, S., John, B., Joung, B., Krishinan, S., Krittayaphong, R., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12669 · Cited by 57
A novel IRBF-RVM model for diagnosis of atrial fibrillation
Kong, D., Zhu, J., Wu, S., Duan, C., Lu, L., & Chen, D. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.05.028 · Cited by 45
Atrial Fibrillation Detection: Fishing for An Irregular Heartbeat Before and After Stroke
Thijs, V. (2017) · Stroke · doi:10.1161/strokeaha.117.017083 · Cited by 49
Seccia, T. M., Caroccia, B., Muiesan, M. L., & Rossi, G. P. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.01.007 · Cited by 51
“com)[58,59] and the MicrolifeWatchBP Home A (http://www.”
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12461 · Cited by 40
Uittenbogaart, S. B., Gurp, N. V.-V., Erkens, P. M. G., Lucassen, W. A. M., Knottnerus, J. A., Winkens, B., van Weert, H. C. P. M., & Stoffers, J. (2015) · Trials · doi:10.1186/s13063-015-1006-5 · Cited by 38
“Recordings are stored locally and are uploaded as a PDF in the local PC application [23].”
MethodDuarte, R., Stainthorpe, A., Mahon, J., Greenhalgh, J., Richardson, M., Nevitt, S., Kotas, E., Boland, A., Thom, H., Marshall, T., et al. (2019) · PLOS ONE · doi:10.1371/journal.pone.0226671 · Cited by 28
“Data from four studies[28, 33–35] were included in the meta-analyses (two studies of MyDiagnostick,[34, 35] one study of Kardia Mobile,[33] and one study MyDiagnostick and Kardia Mobile).”
BackgroundMethodScreening for atrial fibrillation in hospitalised geriatric patients
Tavernier, R., Wolf, M., Kataria, V., Phlips, T., Huys, R., Taghji, P., Louw, R., Hoeyweghen, R. V., Vandekerckhove, Y. R., Knecht, S., et al. (2017) · Heart · doi:10.1136/heartjnl-2017-311981 · Cited by 30
Duarte, R. V., Stainthorpe, A., Greenhalgh, J., Richardson, M., Nevitt, S. J., Mahon, J., Kotas, E., Boland, A., Thom, H. H. Z., Marshall, T. P., et al. (2020) · Health Technology Assessment · doi:10.3310/hta24030 · Cited by 33
Broux, B., Clercq, D. D., Vera, L., Ven, S., Deprez, P. R., Decloedt, A., & van Loon, G. (2018) · BMC Veterinary Research · doi:10.1186/s12917-018-1650-6 · Cited by 22
Electrocardiogram Devices for Home Use: Technological and Clinical Scoping Review
Zepeda-Echavarria, A., van de Leur, R. R., van Sleuwen, M., Hassink, R. J., Wildbergh, T. X., Doevendans, P. A., Jaspers, J., & van Es, R. (2023) · JMIR Cardio · doi:10.2196/44003 · Cited by 33
“Of the 36 articles, 24 (66%) evaluated the devices’ capabilities to diagnose rhythm disorders [15-17,21,24,25,29-35, 37-43,49-56], whereas 7 (20%) reported on capabilities to detect rhythm disorders and other heart conditions, such as cardiomyopathy, conduction disorders, and cardiac ischemia [18,22,23,28,36,45,57].”
BackgroundFay, M., Fitzmaurice, D. A., & Freedman, B. (2017) · European Journal of General Practice · doi:10.1080/13814788.2017.1374366 · Cited by 24
Jiang, H., Tan, S. Y., Wang, J. K., Li, J., Tu, T. M., Tan, V. H., & Yeo, C. (2022) · Open Heart · doi:10.1136/openhrt-2022-002081 · Cited by 22
Karregat, E. P. M., Gurp, N. V.-V., Bouwman, A. C., Uittenbogaart, S. B., Himmelreich, J. C. L., Lucassen, W. A. M., Krul, S. P. J., van Kesteren, H. A. M., LUERMANS, J. G. L. M., van Weert, H. C. P. M., et al. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.10.021 · Cited by 20
Santala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Laitinen, T. P., Laitinen, T. M., Castrén, M. K., Väliaho, E., Rantula, O., et al. (2022) · JMIR Cardio · doi:10.2196/31230 · Cited by 16
“In the previous studies, the sensitivity of automatic AF detection ranged from 67% to 100% and the specificity from 84% to 100% depending on the mobile or digital technology and strategy used [21-36].”
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.11.004 · Cited by 19
“Studies across diverse populations have documented the diagnostic accuracy of handheld devices in detection of AF by shortterm rhythm monitoring (Desteghe 2017, Doliwa 2009, Hendrikx 2014, Kaasenbrood 2016, Poulsen 2017, Svennberg 2017, Tavernier 2018, Tieleman 2014, Vaes 2014) (Table 2).”
BackgroundPharmacists detecting atrial fibrillation in general practice: a qualitative focus group study
Savickas, V., Veale, E. L., Bhamra, S. K., Stewart, A. J., Mathie, A. A., & Corlett, S. A. (2020) · BJGP Open · doi:10.3399/bjgpopen20x101042 · Cited by 17
Screening For Atrial Fibrillation In The Community Using A Novel ECG Recorder.
Battipaglia, I., Gilbert, K., Hogarth, A. J., & Tayebjee, M. H. (2016) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1433 · Cited by 15
Opportunistic screening for atrial fibrillation with a single lead device in geriatric patients.
Zwart, L. A. R., Jansen, R. W. M. M., Ruiter, J. H., Germans, T., Şimşek, S., & Hemels, M. E. W. (2020) · PubMed Central · doi:10.11909/j.issn.1671-5411.2020.03.007 · Cited by 17
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab001 · Cited by 22
NICE atrial fibrillation guideline snubs wearable technology: a missed opportunity?
Gala, A. R. P. B. E., Pope, M., Leo, M., Lobban, T., & Betts, T. R. (2022) · Clinical Medicine · doi:10.7861/clinmed.2021-0436 · Cited by 13
“12,16,17,21,22 The rationale for this is unclear.”
Screening for undiagnosed atrial fibrillation
Sandhu, R. K., & Healey, J. S. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2018.1496018 · Cited by 13
Atrial fibrillation detection with a portable device during cardiovascular screening in primary care
Diamantino, A. C., Nascimento, B. R., Beaton, A., Nunes, M. C. P., Oliveira, K., Rabelo, L. C., Barbosa, M. M., Tompsett, A., Olivieri, L., Mata, M. D. O., et al. (2020) · Heart · doi:10.1136/heartjnl-2019-316277 · Cited by 13
Gurp, N. V.-V., van Mil, D., van Kesteren, H. A. M., Knottnerus, J. A., & Stoffers, J. (2019) · BMC Family Practice · doi:10.1186/s12875-019-1064-y · Cited by 13
Detection of Atrial Fibrillation
Sörnmo, L., Petrėnas, A., & Marozas, V. (2018) · Series in bioengineering · doi:10.1007/978-3-319-68515-1_4 · Cited by 16
Identification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation
Halvaei, H., Svennberg, E., Sörnmo, L., & Stridh, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.672875 · Cited by 13
“Thanks to recent advances in low-cost technology for recording the ECG with a handheld device (Lau et al., 2013; Tieleman et al., 2014; Vaes et al., 2014), mass screening in the home environment has become feasible (Engdahl et al.”
BackgroundLead Systems and Recording Devices
Petrėnas, A., Marozas, V., & Sörnmo, L. (2018) · Series in bioengineering · doi:10.1007/978-3-319-68515-1_2 · Cited by 8
Mobile health adherence for the detection of recurrent recent-onset atrial fibrillation
van der Velden, R. M. J., Pluymaekers, N. A. H. A., Dudink, E. A. M. P., LUERMANS, J. G. L. M., Meeder, J. G., Heesen, W. F., Lenderink, T., Widdershoven, J. W. M. G., Bucx, J. J. J., Rienstra, M., et al. (2022) · Heart · doi:10.1136/heartjnl-2022-321346 · Cited by 8
Kao, W., Hou, S., Huang, C., Chao, C., Cheng, C.-C., & Chen, Y.-J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198852 · Cited by 8
Gahungu, N., Judkins, C., Gabbay, E., & Playford, D. A. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2019.01.036 · Cited by 7
Intelligent algorithms powered smart devices for atrial fibrillation discrimination
Xie, L., Wang, L., Mo, D., Zhang, Z., & Liang, M. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107480 · Cited by 7
Smartphone and new tools for atrial fibrillation diagnosis: evidence for clinical applicability
PAPACCIOLI, G., BASSI, G., Cecilia, L. U. G. I., Parente, E., D’ANDREA, A., PROIETTI, R., Imbalzano, E., TURKI, A. A., & Russo, V. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05841-0 · Cited by 8
Jones, I. D., Lane, D. A., Lotto, R. R., Oxborough, D., Neubeck, L., Penson, P. E., Czanner, G., Shaw, A., Smith, E. J., Santos, A., et al. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12040578 · Cited by 8
“The specificity of MyDiagnostick also compares well with other devices ranging between 93% (95% CI 85–97%) [28] to 95.”
BackgroundMethodIs machine learning the future for atrial fibrillation screening?
Sivanandarajah, P., Wu, H., Bajaj, N., Khan, S. N., & Ng, F. S. (2022) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2022.04.001 · Cited by 9
Gurp, N. V.-V., Uittenbogaart, S. B., Lucassen, W. A. M., Erkens, P. M. G., Knottnerus, J. A., Winkens, B., Stoffers, J., & van Weert, H. C. P. M. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-059172 · Cited by 10
Gu, H., Huang, J., Liu, X., Qiao, S. Q., & Cao, X. (2023) · Worldviews on Evidence-Based Nursing · doi:10.1111/wvn.12667 · Cited by 14
Santala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Väliaho, E., Rantula, O., Naukkarinen, N. S., Hartikainen, J. E. K., Martikainen, T. J., et al. (2023) · Cardiology in Review · doi:10.1097/crd.0000000000000526 · Cited by 11
Malmqvist, J., Engdahl, J., Sjölund, G., & Doliwa, P. S. (2024) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2024.02.001 · Cited by 6
Varma, N., Cygankiewicz, I., & Turakhia, M. P. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4420 · Cited by 7
Approach to atrial fibrillation: Essentials for primary care
Bell, A., Andrade, J. G., Macle, L., Connelly, K. A., LaBine, L., & Singer, A. G. (2023) · Canadian Family Physician · doi:10.46747/cfp.6904245 · Cited by 5
Review of Screening Studies for Atrial Fibrillation in Rural Populations of 11 Countries
Gavino, A., & McLachlan, C. S. (2017) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2017.11929615 · Cited by 7
de Torres, L. Á. P., González-Blanco, V., Luque-Montilla, R., Martín-Rioboó, E., Martínez-Adell, M., & Castroviejo, J. R.-D. (2016) · Medicina de Familia SEMERGEN · doi:10.1016/j.semerg.2016.06.015 · Cited by 6
Diagnostic accuracies of screening for atrial fibrillation by cardiac nurses versus radiographers
Kvist, L. M., Vinter, N., Urbonavičienė, G., Lindholt, J. S., Diederichsen, A. C. P., & Frost, L. (2019) · Open Heart · doi:10.1136/openhrt-2018-000942 · Cited by 8
Jones, I. D., Lane, D. A., Lotto, R. R., Oxborough, D., Neubeck, L., Penson, P. E., Smith, E. J., Santos, A., McGinn, E. E., Ajiboye, A., et al. (2024) · American Heart Journal · doi:10.1016/j.ahj.2024.02.011 · Cited by 5
Relative utility of portable ECG devices in capturing arrhythmias in athletes
Davis, A. J., Driscoll, T., Orchard, J. W., Raju, H., Gray, B. R., & Orchard, J. J. (2024) · Expert Review of Medical Devices · doi:10.1080/17434440.2024.2438313 · Cited by 3
“Handheld monitors have been assessed for accuracy in a variety of populations, including athletes [33–42].”
The involvement of pharmacies in the screening of undiagnosed atrial fibrillation
Modesti, P. A., Donigaglia, G., Fabiani, P., Mumoli, N., Colella, A., & Boddi, M. (2017) · Internal and Emergency Medicine · doi:10.1007/s11739-017-1752-3 · Cited by 5
“The Elba-FA project was thus designed to determine the feasibility and impact of the combined involvement of pharmacies and general practices to screen undiagnosed AF in a confined area of Italy, the Isle of Elba, using innovative ECG technology [35, 36], with the ultimate aim of reducing the burden of stroke and thro…”
MethodValidation of MyDiagnostick tool to identify atrial fibrillation in a multi-ethnic Asian population
Yeo, C., Mon, A., Tan, V. H., & Wong, K. C. K. (2022) · Singapore Medical Journal · doi:10.11622/smedj.2022028 · Cited by 3
“Patients who were newly diagnosed with AF were given referral to their family physician with a copy of the ECG rhythm strip tracing of AF.”
BackgroundMethodInfluentialCarvalho, A. P. V., do Carmo, G. A. L., Silva, C. A., Oliveira, A. C. D. S., Perez, L. G., do Carmo, L. P. D. F., & Ribeiro, A. L. P. (2025) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240450i · Cited by 2
Digital health solutions in the screening of subclinical atrial fibrillation
König, S., Bollmann, A., & Hindricks, G. (2021) · Herz · doi:10.1007/s00059-021-05041-2 · Cited by 2
Zink, M. D., Napp, A., & Gramlich, M. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00711-w · Cited by 3
“[15] showed good diagnostic accuracy with high sensitivity and specificity in cohorts with a high proportion of patients suffering fromAF in a primary care environment.”
BackgroundHabibi, Z., Verhaert, D. V. M., Özgül, O. F., Betz, K., Hermans, B. J. M., Philippens, S., Chaldoupi, S., Maesen, B. A. E., Sandgren, E., Maessen, J. G., et al. (2026) · EP Europace · doi:10.1093/europace/euag044 · Cited by 2
“12,13 Despite the high accuracy of the MyDiagnostick, the single-lead ECGs from the MyDiagnostick were visually inspected by a certified physician to validate AF in the tracing.”
Mobile ECG Devices Selection: A Comprehensive Review
Sladojević, S., Anderla, A., Gutai, A., Arsenović, M., Sladojević, M., Stevanov, B., Sremčev, N., & Pržulj, Đ. (2024) · Tehnički glasnik · doi:10.31803/tg-20230615143201 · Cited by 2
“Another study that showed similar results, high sensitivity and specificity for atrial fibrillation was done by Vaes et al. [53].”
Carvalho, A. P. V., do Carmo, G. A. L., Silva, C. A., Oliveira, A. C. D. S., Perez, L. G., do Carmo, L. P. D. F., & Ribeiro, A. L. P. (2025) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240450 · Cited by 3
“13,14 MyDiagnostick ® is a rod-shaped wand that has sensitive electrodes on both ends of a metal handle.”
Lucassen, W. A. M., Himmelreich, J. C. L., Harskamp, R. E., & Selder, J. L. (2021) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2620-4_30 · Cited by 1
Voorkamerfibrillatie in de eerste lijn: Hoe kan de MyDiagnostick® ondersteuning bieden?
Maes, V., Corne, K., Vaes, B., & Degryse, J. (2016) · Huisarts Nu · doi:10.1007/s40954-016-0078-0
Self-citationHealth Economic Evaluations of Screening Programs - Applications and Method Improvements
Aronsson, M. (2017) · doi:10.3384/diss.diva-141556
“[52, 140, 143-146] Hence, a limitation of our study was to only include handheld ECG as the technique to find previously unknown AF.”
MethodOpsporen van atriumfibrilleren in de huisartsenpraktijk
Kaasenbrood, F. (2020) · Huisarts en Wetenschap · doi:10.1007/s12445-020-0881-5
Gurp, N. V.-V., & van Gurp (2022) · Research Publications (Maastricht University) · doi:10.26481/dis.20220325nv
Performance of the imPulse device for the detection of atrial fibrillation in hospital settings
McDonagh, S. T. J., Rhodes, S. G., Warren, F. C., Keenan, S., Pentecost, C., Keeling, P. J., James, M. A., Taylor, R. S., & Clark, C. E. (2022) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2022.05.002
Gu, H., Huang, J., Liu, X., Qiao, S. Q., & Cao, X. (2022) · doi:10.2196/preprints.43081
Top Portable ECGs in the Status Quo
Chellarapu, S. A., & Cavanaugh, C. (2023) · Journal of Student Research · doi:10.47611/jsrhs.v11i1.2494 · Cited by 1
Jones, I. D., Fitzsimmons, D. A., Musa, M. K., Carroll, P., Smith, E. J., Clowes, M., Carr, J., Fulstow, A., Yates, J., & Lip, G. Y. H. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-087974
Himmelreich, J. C. L., Lucassen, W. A. M., & Harskamp, R. E. (2026) · doi:10.1007/978-90-368-3158-1_28
Metadata
- Authors
- Vaes, B., Stalpaert, S., Tavernier, K., Thaels, B., Lapeire, D., Mullens, W., & Degryse, J.
- Affiliations
- UCLouvain (BE)
- KU Leuven (BE)
- Corresponding author
- Vaes, Bert
- ORCID
- Vaes, Bert
- Venue
- BMC Family Practice
- Published
- 2014-06-09
- Volume
- 15
- Issue
- 1
- Pages
- 113-113
- ISSN
- 1471-2296 (ISSN-L)
- PMC
- PMC4069340
- OpenAlex
- W2107017489
- Semantic Scholar
- 877abe3429c58cbca56dd4d6a5a1bfa8648e0a5f
- Cited by
- 81
- References
- 24
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 12 · 2020: 11 · 2019: 6 · 2018: 7 · 2017: 9 · 2016: 5 · 2015: 3
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMC Family Practice (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Lirias (submittedVersion, cc-by)
- DIAL (Catholic University of Leuven) (submittedVersion, other-oa)
- Document Server@UHasselt (UHasselt) (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Health Promotion and Cardiovascular Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, pulse rate monitoring, diagnostic accuracy, screening, primary care, electrocardiogram, stroke prevention, older adults, case finding
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Diagnosis, Differential, Electrocardiography, Female, Humans, Male, Middle Aged, Primary Health Care, Sensitivity and Specificity, Prevalence, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.


