CoChat

Comparative study of bacteriological culture and real-time fluorescence quantitative PCR (RT-PCR) and multiplex PCR-based reverse line blot (mPCR/RLB) hybridization assay in the diagnosis of bacterial neonatal meningitis

Open access
Wang, Yajuan, Guo, Gaili, Wang, Huixin, Yang, Xuefang, Shao, Fang, Yang, Caiyun, Gao, Wei, Shao, Zhujun, Zhang, Jinjing, Luo, Jie, Yang, Yonghong, Kong, Fanrong, Zhu, Bingqing · 2014 · BMC Pediatrics
Cited by 55

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Bacterial meningitis is more common in the neonatal period than any other time in life; however, it is still a challenge for the evidence based diagnosis. Strategy for identification of neonatal bacterial meningitis pathogens is presented by evaluating three different available methods to establish evidence-based diagnosis for neonatal bacterial meningitis. METHODS: The cerebrospinal fluid samples from 56 neonates diagnosed as bacterial meningitis in 2009 in Beijing Children's Hospital were analyzed in the study. Two PCR based molecular assays, real-time fluorescence quantitative PCR (RT-PCR) and multiplex PCR based-reverse line blot hybridization (mPCR/RLB), were used to assess 7 common neonatal meningitis bacterial pathongens, including Escherichia coli, Staphylococcus aureus, Listerisa monocytogenes, Neisseria meningitidis, Haemophilus influenzae, Streptococcus pneumoniae, and Streptococcus agalactiae. The findings in examinations of two assays were compared with the results obtained bacterial culture tests. RESULTS: Bacterial meningitis was identified in five cases (9%) by CSF cultures, 25 (45%) by RT-PCR and 16 (29%) by mPCR/RLB. One strain of S. epidermidis and one of E. faecalis were identified using mPCR/RLB but not by RT-PCR. In contrast, cultures identified one strain of S. pneumoniae which was missed by both PCR assays. Overall, the bacterial pathogens in 28 cases were identified with these three methods. Both RT-PCR and mPCR/RLB assays were more sensitive than bacterial culture, (p < 0.05). CONCLUSION: Our study confirmed that both RT-PCR and mPCR/RLB assays have better sensitivity than bacterial culture. They are capable of detecting the pathogens in CSF samples with negative culture results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2431-14-224

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 55

Metadata

Authors
Wang, Y., Guo, G., Wang, H., Yang, X., Shao, F., Yang, C., Gao, W., Shao, Z., Zhang, J., Luo, J., Yang, Y., Kong, F., & Zhu, B.
Venue
BMC Pediatrics
Published
2014-09-08
Volume
14
Issue
1
Pages
224-224
ISSN
1471-2431 (ISSN-L)
OpenAlex
W2077012660
Cited by
55
References
3
FWCI
4.60
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative study of bacteriological culture and real-time fluorescence quantitative PCR (RT-PCR) and multiplex PCR-based reverse line blot (mPCR/RLB) hybridization assay in the diagnosis of bacterial neonatal meningitis. https://app.cochat.ai/papers/10.1186/1471-2431-14-224
The paper
Wang, Y., Guo, G., Wang, H., Yang, X., Shao, F., Yang, C., Gao, W., Shao, Z., Zhang, J., Luo, J., Yang, Y., Kong, F., & Zhu, B. (2014). Comparative study of bacteriological culture and real-time fluorescence quantitative PCR (RT-PCR) and multiplex PCR-based reverse line blot (mPCR/RLB) hybridization assay in the diagnosis of bacterial neonatal meningitis. BMC Pediatrics. https://doi.org/10.1186/1471-2431-14-224

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.