CoChat

Comparison of same day diagnostic tools including Gene Xpert and unstimulated IFN-γ for the evaluation of pleural tuberculosis: a prospective cohort study

Open access
Meldau, Richard, Peter, Jonny, Theron, Grant, Calligaro, Greg, Allwood, Brian, Symons, Greg, Khalfey, Hoosain, Ntombenhle, Gina, Govender, Ureshnie, Binder, Anke, van Zyl-Smit, Richard, Dheda, Keertan · 2014 · BMC Pulmonary Medicine
Cited by 75

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The accuracy of currently available same-day diagnostic tools (smear microscopy and conventional nucleic acid amplification tests) for pleural tuberculosis (TB) is sub-optimal. Newer technologies may offer improved detection. METHODS: Smear-microscopy, adenosine deaminase (ADA), interferon gamma (IFN-γ), and Xpert MTB/RIF [using an unprocessed (1 ml) and centrifuged (~20 ml) sample] test accuracy was evaluated in pleural fluid from 103 consecutive patients with suspected pleural TB. Culture for M.tuberculosis and/or histopathology (pleural biopsy) served as the reference standard. Patients were followed prospectively to determine their diagnostic categorisation. RESULTS: Of 93 evaluable participants, 40 had definite-TB (reference positive), 5 probable-TB (not definite but treated for TB) and 48 non-TB (culture and histology negative, and not treated for TB). Xpert MTB/RIF sensitivity and specificity (95% CI) was 22.5% (12.4 - 37.6) and 98% (89.2 - 99.7), respectively, and centrifugation did not improve sensitivity (23.7%). The Xpert MTB/RIF internal positive control showed no evidence of inhibition. Biomarker specific sensitivity, specificity, PPV, and NPVs were: ADA (48.85 IU/L; rule-in cut-point) 55.3% (39.8 - 69.9), 95.2% (83.9 - 98.7), 91.4 (73.4 - 95.4), 69.7% (56.7 - 80.1); ADA (30 IU/L; clinically used cut-point) 79% (63.7 - 89), 92.7% (80.6 - 97.5), 91.0 (73.4 - 95.4), 82.7% (69.3 - 90.1); and IFN-γ (107.7 pg/ml; rule-in cut-point) 92.5% (80.2 - 97.5), 95.9% (86.1 - 98.9), 94.9% (83.2 - 98.6), 93.9% (83.5 - 97.9), respectively (IFN-γ sensitivity and NPV better than Xpert [p < 0.05] and rule-in ADA [p < 0.05]). CONCLUSION: The usefulness of Xpert MTB/RIF to diagnose pleural TB is limited by its poor sensitivity. IFN-γ is an excellent rule-in test and, compared to ADA, has significantly better sensitivity and rule-out value in a TB-endemic setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2466-14-58

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 75

Metadata

Authors
Meldau, R., Peter, J., Theron, G., Calligaro, G., Allwood, B., Symons, G., Khalfey, H., Ntombenhle, G., Govender, U., Binder, A., van Zyl-Smit, R., & Dheda, K.
Venue
BMC Pulmonary Medicine
Published
2014-04-08
Volume
14
Issue
1
Pages
58-58
ISSN
1471-2466 (ISSN-L)
OpenAlex
W2081398921
Cited by
75
References
8
FWCI
5.82
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of same day diagnostic tools including Gene Xpert and unstimulated IFN-γ for the evaluation of pleural tuberculosis: a prospective cohort study. https://app.cochat.ai/papers/10.1186/1471-2466-14-58
The paper
Meldau, R., Peter, J., Theron, G., Calligaro, G., Allwood, B., Symons, G., Khalfey, H., Ntombenhle, G., Govender, U., Binder, A., van Zyl-Smit, R., & Dheda, K. (2014). Comparison of same day diagnostic tools including Gene Xpert and unstimulated IFN-γ for the evaluation of pleural tuberculosis: a prospective cohort study. BMC Pulmonary Medicine. https://doi.org/10.1186/1471-2466-14-58

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.