The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone
Open accessAbstract
BACKGROUND: Polyurethane (PU) foam is widely used as a model for cancellous bone. The higher density foams are used as standard biomechanical test materials, but none of the low density PU foams are universally accepted as models for osteoporotic (OP) bone. The aim of this study was to determine whether low density PU foam might be suitable for mimicking human OP cancellous bone. METHODS: Quasi-static compression tests were performed on PU foam cylinders of different lengths (3.9 and 7.7 mm) and of different densities (0.09, 0.16 and 0.32 g cm(-3)), to determine the Young's modulus, yield strength and energy absorbed to yield. RESULTS: Young's modulus values were 0.08-0.93 MPa for the 0.09 g cm(-3) foam and from 15.1-151.4 MPa for the 0.16 and 0.32 g cm(-3) foam. Yield strength values were 0.01-0.07 MPa for the 0.09 g cm(-3) foam and from 0.9-4.5 MPa for the 0.16 and 0.32 g cm(-3) foam. The energy absorbed to yield was found to be negligible for all foam cylinders. CONCLUSION: Based on these results, it is concluded that 0.16 g cm(-3) PU foam may prove to be suitable as an OP cancellous bone model when fracture stress, but not energy dissipation, is of concern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Cited by
Hounsfield Units for Assessing Bone Mineral Density and Strength: A Tool for Osteoporosis Management
Schreiber, J. J., Anderson, P. A., Rosas, H. G., Buchholz, A. L., & Au, A. G. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00160 · Cited by 941
Lu, Y., Biswas, M. C., Guo, Z., Jeon, J.-W., & Wujcik, E. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.037 · Cited by 391
Metadata
- Authors
- Patel, P. S., Shepherd, D. E., & Hukins, D. W.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2008-10-09
- Volume
- 9
- Issue
- 1
- Pages
- 137-137
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W1983385949
- Cited by
- 197
- References
- 3
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone. https://app.cochat.ai/papers/10.1186/1471-2474-9-137
- The paper
- Patel, P. S., Shepherd, D. E., & Hukins, D. W. (2008). Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone. BMC Musculoskeletal Disorders. https://doi.org/10.1186/1471-2474-9-137
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.