Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Polyurethane (PU) foam is widely used as a model for cancellous bone. The higher density foams are used as standard biomechanical test materials, but none of the low density PU foams are universally accepted as models for osteoporotic (OP) bone. The aim of this study was to determine whether low density PU foam might be suitable for mimicking human OP cancellous bone. METHODS: Quasi-static compression tests were performed on PU foam cylinders of different lengths (3.9 and 7.7 mm) and of different densities (0.09, 0.16 and 0.32 g cm(-3)), to determine the Young's modulus, yield strength and energy absorbed to yield. RESULTS: Young's modulus values were 0.08-0.93 MPa for the 0.09 g cm(-3) foam and from 15.1-151.4 MPa for the 0.16 and 0.32 g cm(-3) foam. Yield strength values were 0.01-0.07 MPa for the 0.09 g cm(-3) foam and from 0.9-4.5 MPa for the 0.16 and 0.32 g cm(-3) foam. The energy absorbed to yield was found to be negligible for all foam cylinders. CONCLUSION: Based on these results, it is concluded that 0.16 g cm(-3) PU foam may prove to be suitable as an OP cancellous bone model when fracture stress, but not energy dissipation, is of concern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666
Molecular mechanistic origin of the toughness of natural adhesives, fibres and composites
Smith, B. L., Schäffer, T. E., Viani, M., Thompson, J. B., Frederick, N. A., Kindt, J., Belcher, A., Stucky, G. D., Morse, D. E., & Hansma, P. K. (1999) · Nature · doi:10.1038/21607 · Cited by 1,218 · cited 1×
“One theory [27] suggests a 'modular' elongation mechanism for the toughness of natural composites such as bone, whereby the domains within a single molecule unfold (or loops open) upon pushing or pulling, so that "sacrificial bonds" are broken before a strong bond is broken (if the force is large enough).”
BackgroundBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961 · cited 1×
“A similar structural response to compression has been observed in the trabeculae of cancellous bone [29].”
BackgroundDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687 · cited 5×
“1–9800 MPa [20-22], and includes human cancellous bone located across the tibia, vertebral bodies and humerus, whilst the yield strength is reported to differ within the range of 0.”
BackgroundInfluentialPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 1×
“Open cell foams are favoured for their compressive fatigue behaviour, where the localised single-cell crush band has been found to be more characteristic of cancellous bone, unlike the expandable crush zone found in closed cell foam under the same strain [25,26].”
BackgroundYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653
Human Physiology: An Integrated Approach
Silverthorn, D. U. (1997) · Cited by 628
Factors Affecting the Pullout Strength of Cancellous Bone Screws
Chapman, J. R., Harrington, R. M., Lee, K. M., Anderson, P. A., Tencer, A. F., & Kowalski, D. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796022 · Cited by 503 · cited 1×
“The PU foam is available in blocks, which have been used to investigate fixation of bone screws [2,3], and will be used in this form for the current study.”
MethodLi, B., & Dr. Aspden, R. M. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.4.641 · Cited by 457 · cited 10×
“The yield strength was determined by the method described by Li and Aspden [14]; i.”
BackgroundMethodResultInfluentialSystematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Tensile and compressive properties of cancellous bone
Røhl, L., Larsen, E., Linde, F., Odgaard, A., & Jørgensen, J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90006-9 · Cited by 279
Widdle, R. D., Bajaj, A. K., & Davies, P. (2007) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2007.09.002 · Cited by 107 · cited 1×
“The reason for choosing this standard was to ensure that the specimens did not bulge during compression; rubbers have a Poisson's value of about 0.5 and so maintain an almost constant volume during compression; as a result, they bulge more than most other materials [17, 18 ].”
InfluentialTechnical note. Characterization of a synthetic foam as a model for human cancellous bone
Szivek, J. A., Thomas, M., & Benjamin, J. B. (1993) · Journal of Applied Biomaterials · doi:10.1002/jab.770040309 · Cited by 89 · cited 1×
“[9,10] measured the elastic modulus, yield and compressive strength of different, closed cell, PU foam compositions (prepared during their study), which provided reproducible mechanical properties falling within a range of cancellous bone properties from various types of patients.”
BackgroundSommers, M. B., Fitzpatrick, D. C., Madey, S. M., Zanderschulp, C. V., & Bottlang, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.04.024 · Cited by 66 · cited 1×
“The determination of such mechanical properties may help selection of the relevant PU foams as an OP cancellous bone model in other studies, for example, in the mechanical evaluation of implant performance [15].”
Szivek, J. A., THOMPSON, J. D., & Benjamin, J. B. (1995) · Journal of Applied Biomaterials · doi:10.1002/jab.770060207 · Cited by 63 · cited 1×
“[9,10] measured the elastic modulus, yield and compressive strength of different, closed cell, PU foam compositions (prepared during their study), which provided reproducible mechanical properties falling within a range of cancellous bone properties from various types of patients.”
BackgroundMechanical properties of open-cell foam synthetic thoracic vertebrae
Johnson, A. E., & Keller, T. S. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3158-7 · Cited by 46 · cited 4×
“Johnson and Keller [8] reported the mechanical properties of two open cell rigid PU foams, with densities of 0.09 g.cm -3 and 0.12 g.cm -3 , as models for synthetic thoracic vertebrae.”
BackgroundInfluentialPalissery, V., Taylor, M., & Browne, M. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/b:jmsm.0000010098.65572.3b · Cited by 45 · cited 2×
“Closed cell foam has been found to exhibit similar static mechanical properties to human cancellous bone, but different characteristics to human bone in fatigue [12], thus supporting the use of 0.”
BackgroundJutley, R. S., Watson, M. A., Shepherd, D. E. T., & Hukins, D. W. L. (2002) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544110260216586 · Cited by 12
Self-citation
Cited by
Hounsfield Units for Assessing Bone Mineral Density and Strength: A Tool for Osteoporosis Management
Schreiber, J. J., Anderson, P. A., Rosas, H. G., Buchholz, A. L., & Au, A. G. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00160 · Cited by 941
Lu, Y., Biswas, M. C., Guo, Z., Jeon, J.-W., & Wujcik, E. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.037 · Cited by 391
Metadata
- Authors
- Patel, P. S., Shepherd, D. E., & Hukins, D. W.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2008-10-09
- Volume
- 9
- Issue
- 1
- Pages
- 137-137
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W1983385949
- Cited by
- 197
- References
- 19
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.