CoChat

Sequencing bias: comparison of different protocols of MicroRNA library construction

Open access
Tian, Geng, Yin, XuYang, Luo, Hong, Xu, XiaoHong, Bolund, Lars, Zhang, XiuQing · 2010 · BMC Biotechnology
Cited by 85

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: MicroRNAs(miRNAs) are 18-25 nt small RNAs playing critical roles in many biological processes. The majority of known miRNAs were discovered by conventional cloning and a Sanger sequencing approach. The next-generation sequencing (NGS) technologies enable in-depth characterization of the global repertoire of miRNAs, and different protocols for miRNA library construction have been developed. However, the possible bias between the relative expression levels and sequences introduced by different protocols of library preparation have rarely been explored. Results: We assessed three different miRNA library preparation protocols, SOLiD, Illumina versions 1 and 1.5, using cloning or SBS sequencing of total RNA samples extracted from skeletal muscles from Hu sheep and Dorper sheep, and then validated 9 miRNAs by qRT-PCR. Our results show that SBS sequencing data highly correlate with Illumina cloning data. The SOLiD data, when compared to Illumina's, indicate more dispersed distribution of length, higher frequency variation for nucleotides near the 3'- and 5'-ends, higher frequency occurrence for reads containing end secondary structure (ESS), and higher frequency for reads that do not map to known miRNAs. qRT-PCR results showed the best correlation with SOLiD cloning data. Fold difference of Hu sheep and Dorper sheep between qRT-PCR result and SBS sequencing data correlated well (r = 0.937), and fold difference of miR-1 and miR-206 among SOLiD cloning data, qRT-PCR and SBS sequencing data was similar. Conclusions: The sequencing depth can influence the quantitative measurement of miRNA abundance, but the discrepancy caused by it was not statistically significant as high correlation was observed between Illumina cloning and SBS sequencing data. Bias of length distribution, sequence variation, and ESS was observed between data obtained with the different protocols. SOLiD cloning data differ from Illumina cloning data mainly because of distinct methods of adapter ligation. The good correlation between qRT-PCR result and SOLiD data might be due to the similarities of the hybridization-based methods. The fold difference analysis indicated that methods based on hybridization may be superior for quantitative measurement of miRNA abundance. Because of the genome sequence of the sheep is not available, our data may not explain how the entire miRNA bias in the natural miRNAs in sheep or other mammal miRNA expression, unbiased artificially synthesized miRNA will help on evaluating the methodology of miRNA library preparation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1472-6750-10-64

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 85

Metadata

Authors
Tian, G., Yin, X., Luo, H., Xu, X., Bolund, L., & Zhang, X.
Venue
BMC Biotechnology
Published
2010-09-06
Volume
10
Issue
1
Pages
64-64
ISSN
1472-6750 (ISSN-L)
OpenAlex
W2031837743
Cited by
85
References
3
FWCI
4.37
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sequencing bias: comparison of different protocols of MicroRNA library construction. https://app.cochat.ai/papers/10.1186/1472-6750-10-64
The paper
Tian, G., Yin, X., Luo, H., Xu, X., Bolund, L., & Zhang, X. (2010). Sequencing bias: comparison of different protocols of MicroRNA library construction. BMC Biotechnology. https://doi.org/10.1186/1472-6750-10-64

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.