A suite of recombinant luminescent bacterial strains for the quantification of bioavailable heavy metals and toxicity testing
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recombinant whole-cell sensors have already proven useful in the assessment of the bioavailability of environmental pollutants like heavy metals and organic compounds. In this work 19 recombinant bacterial strains representing various Gram-positive (Staphylococcus aureus and Bacillus subtilis) and Gram-negative (Escherichia coli, Pseudomonas fluorescens) bacteria were constructed to express the luminescence encoding genes luxCDABE (from Photorhabdus luminescens) as a response to bioavailable heavy metals ("lights-on" metal sensors containing metal-response elements, 13 strains) or in a constitutive manner ("lights-off" constructs, 6 strains). RESULTS: The bioluminescence of all 13 "lights-on" metal sensor strains was expressed as a function of the sub-toxic metal concentrations enabling the quantitative determination of metals bioavailable for these strains. Five sensor strains, constructed for detecting copper and mercury, proved to be target metal specific, whereas eight other sensor strains were simultaneously induced by Cd2+, Hg2+, Zn2+and Pb2+. The lowest limits of determination of the "lights-on" sensor strains for the metals tested in this study were (microg l-1): 0.002 of CH3HgCl, 0.03 of HgCl2, 1.8 of CdCl2, 33 of Pb(NO3)2, 1626 of ZnSO4, 24 of CuSO4 and 340 of AgNO3. In general, the sensitivity of the "lights-on" sensor strains was mostly dependent on the metal-response element used while the selection of host bacterium played a relatively minor role. In contrast, toxicity of metals to the "lights-off" strains was only dependent on the bacterial host so that Gram-positive strains were remarkably more sensitive than Gram-negative ones. CONCLUSION: The constructed battery of 19 recombinant luminescent bacterial strains exhibits several novel aspects as it contains i) metal sensor strains with similar metal-response elements in different host bacteria; ii) metal sensor strains with metal-response elements in different copies and iii) a "lights-off" construct (control) for every constructed recombinant metal sensor strain. To our knowledge, no Gram-positive metal sensor expressing a full bacterial bioluminescence cassette (luxCDABE) has been constructed previously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Cloning: A Laboratory Manual
Sambrook, J., Fritsch, E., & Maniatis, T. (1989) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 133,589
Molecular cloning: A laboratory manual
Deininger, P. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90595-z · Cited by 84,682
The Complete Genome Sequence of Escherichia coli K-12
Blattner, F. R., Plunkett, G., Bloch, C. A., Perna, N. T., Burland, V., Riley, M., Collado-Vides, J., Glasner, J. D., Rode, C. K., Mayhew, G. F., et al. (1997) · Science · doi:10.1126/science.277.5331.1453 · Cited by 7,452 · cited 1×
“Escherichia coli is an enteric Gram-negative bacterium with the sequenced genome [25], well developed methods for genetic modification [26] and various laboratory strains available.”
BackgroundSimon, R., Priefer, U., & Pühler, A. (1983) · Bio/Technology · doi:10.1038/nbt1183-784 · Cited by 7,219 · cited 1×
“Chromosomal insertions to P. fluorescens OS8 For chromosomal insertions, E. coli S17-1 λ pir [ 69 ] was transformed with the appropriate suicide plasmid by CaCl2 method [26] to obtain the donor strains.”
MethodAshburner, M. (1989) · Cold Spring Harbor Laboratory eBooks · Cited by 6,756
Analysis of gene control signals by DNA fusion and cloning in Escherichia coli
Casadaban, M. J., & Cohen, S. N. (1980) · Journal of Molecular Biology · doi:10.1016/0022-2836(80)90283-1 · Cited by 2,477
Miller, V. L., & Mekalanos, J. J. (1988) · Journal of Bacteriology · doi:10.1128/jb.170.6.2575-2583.1988 · Cited by 2,126 · cited 1×
“coli strain SY372 λpir [67] and were based on pTCR241 [68].”
MethodHeinlaan, M., Ivask, A., Blinova, I., Dubourguier, H.-C., & Kahru, A. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2007.11.047 · Cited by 1,522
Self-citationSmith, M. C. M. (1991) · FEBS Letters · doi:10.1016/0014-5793(91)80059-c · Cited by 1,519
Molecular biological methods for Bacillus
Harwood, C. R., & Cutting, S. M. (1990) · Cited by 1,430
The toxic shock syndrome exotoxin structural gene is not detectably transmitted by a prophage
Kreiswirth, B. N., Löfdahl, S., Betley, M. J., O'Reilly, M., Schlievert, P. M., Bergdoll, M. S., & Novick, R. P. (1983) · Nature · doi:10.1038/305709a0 · Cited by 1,326 · cited 10×
“The culture media were supplemented with antibiotics as follows: ampicillin 100 μg ml-1 (E. coli MC1061(pmerRBSBPmerlux), MC1061(pSLlux)), ampicillin 100 μg ml-1 plus tetracycline 10 μg ml-1 (E. coli MC106 (pSLcueR/ pDNPcopAlux), MC1061(pSLzntR/pDNPzntAlux)), tetracycline 10 μg ml-1 (MC1061(pDNlux)) and 20 μg ml-1 (P.…”
MethodInfluentialToxicity of nanoparticles of CuO, ZnO and TiO2 to microalgae Pseudokirchneriella subcapitata
Aruoja, V., Dubourguier, H.-C., Kasemets, K., & Kahru, A. (2009) · Science of The Total Environment · doi:10.1016/j.scitotenv.2008.10.053 · Cited by 1,259
Self-citationde Lorenzo, V., & Timmis, K. N. (1994) · Methods in Enzymology · doi:10.1016/0076-6879(94)35157-0 · Cited by 879
Parvez, S., Venkataraman, C., & Mukherji, S. (2006) · Environment International · doi:10.1016/j.envint.2005.08.022 · Cited by 461 · cited 1×
“The most popular such tests are Microtox®, BioToxTM, LUMIStoxTM, ToxAlertTM, which measure the effect of the sample on the luminescence of a naturally bioluminescent bacterium Vibrio fischeri [3].”
MethodRapid, Sensitive Bioluminescent Reporter Technology for Naphthalene Exposure and Biodegradation
King, J. M., DiGrazia, P. M., Applegate, B. M., Burlage, R. S., Sanseverino, J., Dunbar, P., Larimer, F. W., & Sayler, G. S. (1990) · Science · doi:10.1126/science.249.4970.778 · Cited by 459 · cited 1×
“The first recombinant luminescent "lights-on" sensors were constructed in 1991 for naphthalene [5] and mercury [6].”
BackgroundDaunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith-Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 445 · cited 3×
“In most of these sensors, the bioluminescence-encoding genes from Vibrio fischeri (that may become labile in temperatures above 30°C [4] and thus, restrict testing) has been used.”
BackgroundBioluminescent sensors for detection of bioavailable Hg(II) in the environment
Selifonova, O., Burlage, R., & Barkay, T. (1993) · Applied and Environmental Microbiology · doi:10.1128/aem.59.9.3083-3090.1993 · Cited by 358 · cited 3×
“Although the relevance of this bacterium for environmental testing is questionable, it has been widely used in the construction of various bacterial sensors [9,10,12,14,17], mainly due to its compatibility with the chemical-response elements used.”
BackgroundNunn, D., Bergman, S., & Lory, S. (1990) · Journal of Bacteriology · doi:10.1128/jb.172.6.2911-2919.1990 · Cited by 348 · cited 5×
“The resulting plasmid pSLcueRPcopAlux was digested with NaeI and the fragment containing the promoter of copA and the luxCDABE was inserted into BamHI-digested and Klenow-treated pDN18N [64].”
MethodInfluentialImproved method for electroporation of Staphylococcus aureus
Schenk, S., & Laddaga, R. A. (1992) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.1992.tb05302.x · Cited by 344
Outten, F. W., Outten, C. E., Hale, J., & O'Halloran, T. V. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m006508200 · Cited by 339 · cited 1×
“However, background luminescence values in the sensor strains were also registered in the absence of added heavy metals (Tables 1, 2, 3, 4). The reason for this could be either the leakage of the promoter controlling the expression of luxgenes and/or as proposed by [ 42 ] metal impurities of the test medium.”
BackgroundO'Halloran, T. V., Frantz, B., Shin, M. K., Ralston, D. M., & Wright, J. G. (1989) · Cell · doi:10.1016/0092-8674(89)90990-2 · Cited by 286 · cited 1×
“coli strains and it is well known that the regulatory protein in this sensor, MerR, is a strong repressor in the absence of mercury [43,44].”
BackgroundMolecular Microbiology of Heavy Metals
(2007) · Microbiology Monographs · doi:10.1007/978-3-540-69771-8 · Cited by 282
Borremans, B., Hobman, J. L., Provoost, A., Brown, N. L., & van der Lelie, D. (2001) · Journal of Bacteriology · doi:10.1128/jb.183.19.5651-5658.2001 · Cited by 279 · cited 1×
“The heavy metal response elements used originated from resistance systems for Hg (from Serratia marcescens plasmid [27]; mer), Pb (from Ralstonia metallidurans CH34 plasmid pMOL30 [33]; pbr), Cd (from Pseudomonas putida choromosome [34]; cad), Cu (cue/cop) and Zn (znt) (both from E.”
BackgroundCorbisier, P., van der Lelie, D., Borremans, B., Provoost, A., de Lorenzo, V., Brown, N. L., Lloyd, J. R., Hobman, J. L., Csöregi, E., Johansson, G., et al. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00725-9 · Cited by 263
ZntR is a Zn(II)‐responsive MerR‐like transcriptional regulator of zntA in Escherichia coli
Brocklehurst, K. R., Hobman, J. L., Lawley, B., Blank, L., Marshall, S. J., Brown, N. L., & Morby, A. P. (1999) · Molecular Microbiology · doi:10.1046/j.1365-2958.1999.01229.x · Cited by 250 · cited 3×
“The heavy metal response elements used originated from resistance systems for Hg (from Serratia marcescens plasmid [27]; mer), Pb (from Ralstonia metallidurans CH34 plasmid pMOL30 [33]; pbr), Cd (from Pseudomonas putida choromosome [34]; cad), Cu (cue/cop) and Zn (znt) (both from E. coli chromosome [28, 29 ]) [see Add…”
BackgroundInfluentialStoyanov, J. V., Hobman, J. L., & Brown, N. L. (2001) · Molecular Microbiology · doi:10.1046/j.1365-2958.2001.02264.x · Cited by 241 · cited 2×
“... genes in response to subtoxic concentrations of bioavailable heavy metals ("lights-on" sensors) were constructed: E. coli MC1061(pmerRBSBPmerlux), E. coli MC1061(pSLcueR/ pDNPcopAlux) and E. coli MC1061(pSLzntR/pDNPzntAlux) (Table 1). All the strains harbour plasmid(s) containing metal-response elements from resis…”
BackgroundLuminescent bacterial sensor for cadmium and lead
Tauriainen, S., Karp, M., Chang, W., & Virta, M. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00027-x · Cited by 240 · cited 3×
“Gram-positive strains Plasmids pcadCPcadAlux and p602/22lux were constructed by inserting the SmaI-SpeI-digested 5700 bp luxCDABE from pSB2025 (translational signals before the genes have been optimized for Gram-positive bacteria) [37,70] into NheI-BamHI-digested (BamHI-digested end was filled with Klenow fragment) pT…”
MethodHakkila, K., Maksimow, M., Karp, M. T., & Virta, M. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5517 · Cited by 235 · cited 2×
“subtilis BR151(pcadCPcadAlux) – were similar in sensitivity with the most sensitive previously reported strains for Hg and Cd, respectively [10,11,16,52].”
BackgroundBiotests and Biosensors for Ecotoxicology of Metal Oxide Nanoparticles: A Minireview
Kahru, A., Dubourguier, H.-C., Blinova, I., Ivask, A., & Kasemets, K. (2008) · Sensors · doi:10.3390/s8085153 · Cited by 219 · cited 1×
“in quantification of solubilized bioavailable metals from metal-containing nanoparticles [57-59].”
BackgroundSelf-citationLee, S.-W., Glickmann, E., & Cooksey, D. A. (2001) · Applied and Environmental Microbiology · doi:10.1128/aem.67.4.1437-1444.2001 · Cited by 210 · cited 1×
“The heavy metal response elements used originated from resistance systems for Hg (from Serratia marcescens plasmid [27]; mer), Pb (from Ralstonia metallidurans CH34 plasmid pMOL30 [33]; pbr), Cd (from Pseudomonas putida choromosome [34]; cad), Cu (cue/cop) and Zn (znt) (both from E.”
BackgroundWhole-cell living biosensors—are they ready for environmental application?
Harms, H., Wells, M. C., & van der Meer, J. R. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0319-4 · Cited by 197
agr Expression Precedes Escape of Internalized Staphylococcus aureus from the Host Endosome
Qazi, S. N. A., Counil, E., Morrissey, J., Rees, C. E. D., Cockayne, A., Winzer, K., Chan, W. C., Williams, P., & Hill, P. J. (2001) · Infection and Immunity · doi:10.1128/iai.69.11.7074-7082.2001 · Cited by 186 · cited 3×
“Plasmids pcadCPcadAlux and p602/22lux were constructed by inserting the SmaI-SpeI-digested 5700 bp lux-CDABE from pSB2025 (translational signals before the genes have been optimized for Gram-positive bacteria) [ 37 ,70] into NheI-BamHI-digested (BamHI-digested end was filled with Klenow fragment) pTOO24 [36] or p602/…”
MethodResultInfluentialApplication of a mer-lux biosensor for estimating bioavailable mercury in soil
Rasmussen, L. D., Sørensen, S. J., Turner, R. R., & Barkay, T. (2000) · Soil Biology and Biochemistry · doi:10.1016/s0038-0717(99)00190-x · Cited by 172 · cited 4×
“Although the relevance of this bacterium for environmental testing is questionable, it has been widely used in the construction of various bacterial sensors [9,10,12,14,17], mainly due to its compatibility with the chemical-response elements used.”
BackgroundMethodResultInfluentialRalston, D. M., & O’Halloran, T. V. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.10.3846 · Cited by 167 · cited 1×
“... elements (E. coli MC1061(pmerRBSBPmerlux), P. fluorescens OS8(pDNmerRBSBPmerlux) and OS8::KnmerRBSBPmerlux)) showed also relatively high specificity, by being induced only with inorganic and organic mercury compounds and Cd. However, induction with the latter occurred at concentrations 3-4 orders of magnitude high…”
ResultGriffin, H. G., Foster, T. J., Silver, S. D., & Misra, T. K. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.10.3112 · Cited by 149 · cited 2×
“All the strains harbour plasmid(s) containing metal-response elements from resistance systems for Hg (from Serratia marcescens plasmid [27]; mer), Cu (cue/cop) and Zn (znt) (both from E.”
BackgroundA microbial biosensor to predict bioavailable nickel in soil and its transfer to plants
Tibazarwa, C., Corbisier, P., Mench, M. J., Bossus, A., Solda, P., Mergeay, M., Wyns, L., & van der Lelie, D. (2001) · Environmental Pollution · doi:10.1016/s0269-7491(00)00177-9 · Cited by 144
Leedjärv, A., Ivask, A., & Virta, M. (2007) · Journal of Bacteriology · doi:10.1128/jb.01494-07 · Cited by 142 · cited 1×
“However, E. coli proved more sensitive than P. fluorescens towards Zn (about 3-fold), Cu (about 15-fold) and Cd (about 100-fold) (Tables 1, 2 and 3). Indeed, relatively low sensitivity of a Pseudomonas putida towards Cd (about 3 orders of magnitude lower than the sensitivity of E. coli) in a growth ihibition assay has…”
ResultSelf-citationHakkila, K., Green, T., Leskinen, P., Ivask, A., Marks, R. S., & Virta, M. (2004) · Journal of Applied Toxicology · doi:10.1002/jat.1020 · Cited by 136 · cited 2×
“Response of either metal sensor or control bacteria was expressed as normalised luminescence (NL) calculated as in [63] according to the following formula:”
MethodSelf-citationVersatile biosensor vectors for detection and quantification of mercury
Hansen, L. H., & Sørensen, S. J. (2000) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.2000.tb09413.x · Cited by 124
Transcriptional Regulation of the Mercury-resistance Genes of Transposon Tn501
Lund, P. A., Ford, S. J., & Brown, N. (1986) · Microbiology · doi:10.1099/00221287-132-2-465 · Cited by 123 · cited 1×
“coli strains and it is well known that the regulatory protein in this sensor, MerR, is a strong repressor in the absence of mercury [43,44].”
BackgroundIvask, A., Green, T., Polyak, B., Mor, A., Kahru, A., Virta, M., & Marks, R. S. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.019 · Cited by 122 · cited 1×
“However, due to the complexity of the environmental samples (colour, turbidity, mixed pollution) and the sensitivity of the used reporter system (bioluminescence is closely related to the energetic status of the cell [18]), several researchers [13,17, 19-24 ] have recognized the need for relevant controls which enable…”
BackgroundSelf-citationRiether, K., Dollard, M.-A., & Billard, P. (2001) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-001-0852-0 · Cited by 114 · cited 4×
“Although the relevance of this bacterium for environmental testing is questionable, it has been widely used in the construction of various bacterial sensors [9,10,12,14,17], mainly due to its compatibility with the chemical-response elements used.”
BackgroundInfluentialBacterial Transition Metal Homeostasis
Nies, D. H. (2007) · Springer eBooks · doi:10.1007/7171_2006_075 · Cited by 101
A Recombinant Escherichia coli Sensor Strain for the Detection of Tetracyclines
Korpela, M., Kurittu, J. S., Karvinen, J. T., & Karp, M. T. (1998) · Analytical Chemistry · doi:10.1021/ac980740e · Cited by 101 · cited 1×
“Plasmid pmerRBSBPmerlux was constructed by ligating the 4600 bp BamHI-NheI-digested and Klenow-treated fragment of pmerRBSBluc [49] and 3200 bp EcoRI-XcmIdigested and T4-treated fragment of pTetlux [62].”
MethodTom‐Petersen, A., Hosbond, C., & Nybroe, O. (2001) · FEMS Microbiology Ecology · doi:10.1016/s0168-6496(01)00174-x · Cited by 92
A genomic approach to gene fusion technology
Dyk, T. K. V., Wei, Y. W., Hanafey, M. K., Dolan, M., Reeve, M. J. G., Rafalski, J. A., Rothman‐Denes, L. B., & LaRossa, R. A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.041620498 · Cited by 84 · cited 1×
“strains [ 54 ]. However, our data on P. fluorescens with chromosomal insertions showed lower background luminescence but not higher sensitivity than the respective plasmid-containing strains (Figure 1B, C).”
ResultPhysiological considerations of environmental applications of lux reporter fusions
Heitzer, A., Applegate, B. M., Kehrmeyer, S. R., Pinkart, H. C., Webb, O. F., Phelps, T. J., White, D. C., & Sayler, G. S. (1998) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(98)00043-8 · Cited by 83 · cited 1×
“However, due to the complexity of the environmental samples (colour, turbidity, mixed pollution) and the sensitivity of the used reporter system (bioluminescence is closely related to the energetic status of the cell [18]), several researchers [13,17,19-24] have recognized the need for relevant controls which enable a…”
BackgroundAnalysis of bioavailable phenols from natural samples by recombinant luminescent bacterial sensors
Leedjärv, A., Ivask, A., Virta, M., & Kahru, A. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2006.01.026 · Cited by 78 · cited 5×
“Plasmid pDNpbrRPpbrAlux was constructed by ligating the BamHI-XhoI-digested pSLlux [32] and BamHI-XhoIdigested 650 bp PCR product containing pbrR and promoter of pbrA (primers: 5' ATATCTCGAGGGGAGCCT-”
BackgroundMethodInfluentialSelf-citationCell-density-dependent sensitivity of a mer-lux bioassay
Rasmussen, L. D., Turner, R. R., & Barkay, T. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.8.3291-3293.1997 · Cited by 74 · cited 1×
“subtilis BR151(pcadCPcadAlux) – were similar in sensitivity with the most sensitive previously reported strains for Hg and Cd, respectively [10,11,16,52].”
BackgroundConstruction and evaluation of a metal ion biosensor
Tescione, L. D., & Belfort, G. (1993) · Biotechnology and Bioengineering · doi:10.1002/bit.260420805 · Cited by 73 · cited 4×
“Although the relevance of this bacterium for environmental testing is questionable, it has been widely used in the construction of various bacterial sensors [9,10,12,14,17], mainly due to its compatibility with the chemical-response elements used.”
BackgroundInfluentialENVIRONMENTAL HAZARD OF THE WASTE STREAMS OF ESTONIAN OIL SHALE INDUSTRY: AN ECOTOXICOLOGICAL REVIEW
Kahru, A., & Põllumaa, L. (2006) · Oil Shale · doi:10.3176/oil.2006.1.06 · Cited by 71 · cited 1×
“The "lights-off" bacterial strains have been extensively used for toxicity testing of pure compounds as well as environmental samples [1, 2 ] already for decades.”
BackgroundSelf-citationSarand, I., Haario, H., Jørgensen, K. S., & Romantschuk, M. (2000) · FEMS Microbiology Ecology · doi:10.1016/s0168-6496(99)00092-6 · Cited by 61
Expression of luciferase genes from different origins in Bacillus subtilis
Lampinen, J., Koivisto, L., Wahlsten, M., Mäntsälä, P., & Karp, M. T. (1992) · Molecular and General Genetics MGG · doi:10.1007/bf00266255 · Cited by 52 · cited 4×
“subtilis strain containing a helper plasmid pBL1 (expresses LacIrepressor) [38].”
BackgroundMethodResultInfluentialPetänen, T., Virta, M., Karp, M. T., & Romantschuk, M. (2001) · Microbial Ecology · doi:10.1007/s002480000095 · Cited by 48
Bioluminescence-based bioassays for rapid detection of nisin in food
Immonen, N., & Karp, M. T. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.029 · Cited by 47 · cited 1×
“Gram-positive strains Plasmids pcadCPcadAlux and p602/22lux were constructed by inserting the SmaI-SpeI-digested 5700 bp luxCDABE from pSB2025 (translational signals before the genes have been optimized for Gram-positive bacteria) [37,70] into NheI-BamHI-digested (BamHI-digested end was filled with Klenow fragment) pT…”
MethodGolding, G. R., Sparling, R., & Kelly, C. A. (2007) · Applied and Environmental Microbiology · doi:10.1128/aem.00717-07 · Cited by 44 · cited 1×
“... elements (E. coli MC1061(pmerRBSBPmerlux), P. fluorescens OS8(pDNmerRBSBPmerlux) and OS8::KnmerRBSBPmerlux)) showed also relatively high specificity, by being induced only with inorganic and organic mercury compounds and Cd. However, induction with the latter occurred at concentrations 3-4 orders of magnitude high…”
ResultBrandt, K. K., Holm, P. E., & Nybroe, O. (2006) · Environmental Toxicology and Chemistry · doi:10.1897/05-558r.1 · Cited by 42 · cited 3×
“Currently, recombinant bacterial "lights-on" heavy metal sensors expressing bacterial bioluminescence system as a reporter include sensors for Cd, Pb [8], Hg [8-12], Cr [8], Ni, Co [13], Zn, Cu [8,14,15] and As [16].”
BackgroundMethodPeltola, P., Ivask, A., Åström, M., & Virta, M. (2005) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2005.01.029 · Cited by 41 · cited 1×
“However, due to the complexity of the environmental samples (colour, turbidity, mixed pollution) and the sensitivity of the used reporter system (bioluminescence is closely related to the energetic status of the cell [18]), several researchers [13,17,19-24] have recognized the need for relevant controls which enable a…”
BackgroundSelf-citation
Cited by
From ecotoxicology to nanoecotoxicology
Kahru, A., & Dubourguier, H.-C. (2010) · Toxicology · doi:10.1016/j.tox.2009.08.016 · Cited by 788
Self-citationToxicity of nanoparticles of ZnO, CuO and TiO2 to yeast Saccharomyces cerevisiae
Kasemets, K., Ivask, A., Dubourguier, H.-C., & Kahru, A. (2009) · Toxicology in Vitro · doi:10.1016/j.tiv.2009.05.015 · Cited by 627
Self-citationToxicity Mechanisms in Escherichia coli Vary for Silver Nanoparticles and Differ from Ionic Silver
Ivask, A., ElBadawy, A., Kaweeteerawat, C., Boren, D., Fischer, H., Ji, Z., Chang, C. H., Liu, R., Tolaymat, T., Telesca, D., et al. (2014) · ACS Nano · doi:10.1021/nn4044047 · Cited by 599
Self-citationIvask, A., Kurvet, I., Kasemets, K., Blinova, I., Aruoja, V., Suppi, S., Vija, H., Käkinen, A., Titma, T., Heinlaan, M., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102108 · Cited by 591
Self-citationWhere microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Metadata
- Authors
- Ivask, A., Rõlova, T., & Kahru, A.
- Venue
- BMC Biotechnology
- Published
- 2009
- Volume
- 9
- Issue
- 1
- Pages
- 41
- ISSN
- 1472-6750 (ISSN-L)
- OpenAlex
- W2035004250
- Cited by
- 201
- References
- 58
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.