Cross-reactivity of steroid hormone immunoassays: clinical significance and two-dimensional molecular similarity prediction
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Immunoassays are widely used in clinical laboratories for measurement of plasma/serum concentrations of steroid hormones such as cortisol and testosterone. Immunoassays can be performed on a variety of standard clinical chemistry analyzers, thus allowing even small clinical laboratories to do analysis on-site. One limitation of steroid hormone immunoassays is interference caused by compounds with structural similarity to the target steroid of the assay. Interfering molecules include structurally related endogenous compounds and their metabolites as well as drugs such as anabolic steroids and synthetic glucocorticoids. METHODS: Cross-reactivity of a structurally diverse set of compounds were determined for the Roche Diagnostics Elecsys assays for cortisol, dehydroepiandrosterone (DHEA) sulfate, estradiol, progesterone, and testosterone. These data were compared and contrasted to package insert data and published cross-reactivity studies for other marketed steroid hormone immunoassays. Cross-reactivity was computationally predicted using the technique of two-dimensional molecular similarity. RESULTS: The Roche Elecsys Cortisol and Testosterone II assays showed a wider range of cross-reactivity than the DHEA sulfate, Estradiol II, and Progesterone II assays. 6-Methylprednisolone and prednisolone showed high cross-reactivity for the cortisol assay, with high likelihood of clinically significant effect for patients administered these drugs. In addition, 21-deoxycortisol likely produces clinically relevant cross-reactivity for cortisol in patients with 21-hydroxylase deficiency, while 11-deoxycortisol may produce clinically relevant cross-reactivity in 11β-hydroxylase deficiency or following metyrapone challenge. Several anabolic steroids may produce clinically significant false positives on the testosterone assay, although interpretation is limited by sparse pharmacokinetic data for some of these drugs. Norethindrone therapy may impact immunoassay measurement of testosterone in women. Using two-dimensional similarity calculations, all compounds with high cross-reactivity also showed a high degree of similarity to the target molecule of the immunoassay. CONCLUSIONS: Compounds producing cross-reactivity in steroid hormone immunoassays generally have a high degree of structural similarity to the target hormone. Clinically significant interactions can occur with structurally similar drugs (e.g., prednisolone and cortisol immunoassays; methyltestosterone and testosterone immunoassays) or with endogenous compounds such as 21-deoxycortisol that can accumulate to very high concentrations in certain disease conditions. Simple similarity calculations can help triage compounds for future testing of assay cross-reactivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Serum T3 or free T3 (fT3) levels are generally not helpful in diagnosing CH; most patients with CH have low fT3 levels, but there is considerable overlap between CH and non-CH patients with pituitary MAY 4, 2016 disease (75,77).”
From Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline (2016) · cites this paper as [75]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Many patients with CH have undetectable TSH levels on presentation, and almost all CH patients adequately treated with L-T4 to maintain serum fT4 levels in the mid-to high-normal range will have undetectable TSH levels (75,80,127,129).”
From Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline (2016) · cites this paper as [75]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics
Burtis, E. B. C. A., Ashwood, E. R., & Bruns, D. E. (2011) · Medical Entomology and Zoology · Cited by 2,190
Molecular similarity: a key technique in molecular informatics
Bender, A., & Glen, R. C. (2004) · Organic & Biomolecular Chemistry · doi:10.1039/b409813g · Cited by 614 · cited 1×
“Comparison of similarity of test molecules to the target compounds of the steroid immunoassays used twodimensional (2D) similarity analysis, which determines the similarity between molecules independent of any in vitro data [52-54].”
In silico pharmacology for drug discovery: applications to targets and beyond
Ekins, S., Mestres, J., & Testa, B. (2007) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707306 · Cited by 365 · cited 2×
“Comparison of similarity of test molecules to the target compounds of the steroid immunoassays used twodimensional (2D) similarity analysis, which determines the similarity between molecules independent of any in vitro data [52-54].”
Self-citationVirtual Screening in Drug Discovery - A Computational Perspective
Reddy, A. S., Pati, S. P., Kumar, P. P., Pradeep, H. N., & Sastry, G. N. (2007) · Current Protein & Peptide Science · doi:10.2174/138920307781369427 · Cited by 350 · cited 1×
“Comparison of similarity of test molecules to the target compounds of the steroid immunoassays used twodimensional (2D) similarity analysis, which determines the similarity between molecules independent of any in vitro data [52-54].”
Septic Shock and Sepsis: A Comparison of Total and Free Plasma Cortisol Levels
Ho, J. T., Al-Musalhi, H., Chapman, M. J., Quach, T., Thomas, P. D., Bagley, C. J., Lewis, J. G., & Torpy, D. J. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0265 · Cited by 312 · cited 4×
“These methods have been applied in our previous publications on cross-reactivity of drug of abuse and therapeutic drug monitoring immunoassays [14-17].”
InfluentialAdvantages and challenges of mass spectrometry assays for steroid hormones
Stanczyk, F. Z., & Clarke, N. J. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.05.001 · Cited by 265 · cited 1×
“However, a growing number of studies have documented differences between immunoassays and mass spectrometry methods (especially LC/ MS/MS) [6,7,58-63].”
Steroid Hormone Analysis by Tandem Mass Spectrometry
Soldin, S. J., & Soldin, O. P. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2007.100008 · Cited by 264 · cited 3×
“Cross-reactivity to endogenous or exogenous compounds other than the target steroid hormone of the assay may also contribute to differences between immunoassay and LC/MS/MS [4,7,34,60,61].”
Shackleton, C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.02.017 · Cited by 226 · cited 2×
“However, a growing number of studies have documented differences between immunoassays and mass spectrometry methods (especially LC/ MS/MS) [6,7,58-63].”
Huhtaniemi, I. T., Tajar, A., Lee, D. M., O'Neill, T. W., Finn, J. D., Bartfai, G., Boonen, S., Casanueva, F. F., Giwercman, A., Han, T. S., et al. (2012) · European Journal of Endocrinology · doi:10.1530/eje-11-1051 · Cited by 201 · cited 2×
“Estradiol immunoassays often do not perform well relative to LC/MS/MS in measuring the lower end of estradiol concentrations found in males, a limitation likely related primarily to differing lower limits of quantitation between the methods [59,62,64,65].”
Evans, T. R. J., di Salle, E., Ornati, G., Lassus, M., Benedetti, M. S., Pianezzola, E., & Coombes, R. C. (1992) · PubMed · Cited by 161
Research works printed but not linked: 1
- Powers DM Boyd JC Glick MR Interference testing in clinical chemistry (EP7-A) 1986 NCCLS: Villanova, PA
Cited by
Consensus on diagnosis and management of Cushing's disease: a guideline update
Fleseriu, M., Auchus, R., Bancos, I., Ben-Shlomo, A., Bertherat, J., Biermasz, N. R., Boguszewski, C. L., Bronstein, M. D., Buchfelder, M., Carmichael, J. D., et al. (2021) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00235-7 · Cited by 953
Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline
Fleseriu, M., Hashim, I. A., Karavitaki, N., Melmed, S., Murad, M. H., Salvatori, R., & Samuels, M. H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2118 · Cited by 945
Measuring cortisol in serum, urine and saliva—Are our assays good enough?
El-Farhan, N., Rees, D. A., & Evans, C. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216687335 · Cited by 395
Yeasmin, S., Wu, B., Liu, Y., Ullah, A., & Cheng, L.-J. “. (2022) · SSRN Electronic Journal · doi:10.1016/j.bios.2022.114142 · Cited by 162
High-Affinity Nucleic-Acid-Based Receptors for Steroids
Yang, K.-A., Chun, H.-S., Zhang, Y., Pecic, S., Nakatsuka, N., Andrews, A. M., Worgall, T. S., & Stojanović, M. N. (2017) · ACS Chemical Biology · doi:10.1021/acschembio.7b00634 · Cited by 134
Hormone Immunoassay Interference: A 2021 Update
Ghazal, K., Brabant, S., Prie, D., & Piketty, M.-L. (2022) · Annals of Laboratory Medicine · doi:10.3343/alm.2022.42.1.3 · Cited by 126
Electrochemical sensors for cortisol detections: Almost there
Zea, M., Bellagambi, F. G., Halima, H. B., Zine, N., Jaffrezic-Renault, N. J., Villa, R., Gabriel, G., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116058 · Cited by 128
Champagne, C. D., Kellar, N. M., Trego, M. L., Delehanty, B., Boonstra, R., Wasser, S. K., Booth, R. K., Crocker, D. E., & Houser, D. S. (2018) · General and Comparative Endocrinology · doi:10.1016/j.ygcen.2018.05.015 · Cited by 96
Manickam, P., Pasha, S. K., Snipes, S. A., & Bhansali, S. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.0781702jes · Cited by 78
Gold, A., Langlois, D. K., & Refsal, K. (2016) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.14589 · Cited by 71
“Conversely, some glucocorticoids could cross-react with the cortisol assay resulting in an erroneously high basal cortisol concentration in an animal with hypoadrenocorticism.(32) One limitation of our study was its retrospective nature.”
Analytical techniques for steroid estrogens in water samples - A review
Fang, T. Y., Praveena, S. M., deBurbure, C., Aris, A. Z., Ismail, S. N. S., & Rasdi, I. B. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.09.051 · Cited by 69
“Cross binding to exogenous compounds rather than the target steroid hormone of the assay may also contribute to differences between immunoassay including ELISA (Krasowski et al., 2014).”
Liu, H., Qin, W., Li, X., Feng, L., Gu, C., Chen, J., Tian, Z., Chen, J., Yang, M., Qiao, H., et al. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c01715 · Cited by 68
Multicenter performance evaluation of a second generation cortisol assay
Vogeser, M., Kratzsch, J., Ju Bae, Y., Bruegel, M., Ceglarek, U., Fiers, T., Gaudl, A., Kurka, H., Milczynski, C., Prat Knoll, C., et al. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0400 · Cited by 65
“One major limitation of immunoassays is their specificity with interference of structurally similar compounds, for example endogenous steroids such as cortisone, or other steroid drugs such as prednisolone or dexamethasone [13, 14].”
Davis, S. R., Bell, R. J., Robinson, P. J., Handelsman, D. J., Gilbert, T., Phung, J., Desai, R., Lockery, J. E., Woods, R. L., Wolfe, R. S., et al. (2019) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2019-00743 · Cited by 60
Borresen, S. W., Klose, M., Baslund, B., Rasmussen, Å. K., Hilsted, L., Friis-Hansen, L., Locht, H., Hansen, A., Hetland, M. L., Lydolph, M. C., et al. (2017) · European Journal of Endocrinology · doi:10.1530/eje-17-0251 · Cited by 63
Rapidity and Precision of Steroid Hormone Measurement
Karashima, S., & Osaka, I. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11040956 · Cited by 63
“6-Methylprednisolone and prednisolone also showed high cross-reactivity in cortisol assays and were shown to be likely to have clinically significant effects in patients receiving these drugs [42].”
Endocrine Disruptors of the Bisphenol and Paraben Families and Bone Metabolism
Vítků, J., Kolátorová, L., Franeková, L., Blahoš, J., Šimková, M., Dušková, M., Škodová, T., & Stárka, L. (2018) · Physiological Research · doi:10.33549/physiolres.934005 · Cited by 52
“Nonetheless, a substantial number of studies report differences in analyte concentrations measured by immunoassays and mass spectrometric techniques (Fanelli et al. 2011, Krasowski et al. 2014, Wood et al. 2008).”
Circulating steroid hormone variations throughout different stages of prostate cancer
Snaterse, G., Visser, J. A., Arlt, W., & Hofland, J. (2017) · Endocrine Related Cancer · doi:10.1530/erc-17-0155 · Cited by 51
Jaff, N. G., Norris, S. A., Snyman, T., Toman, M., & Crowther, N. J. (2015) · Metabolism · doi:10.1016/j.metabol.2015.05.009 · Cited by 47
“[58] Krasowski MD, Drees D, Morris CS, Maakestad J, Blau JL, Ekins SE.”
BackgroundMethodAdrenal and thyroid function in the fetus and preterm infant
Chung, H. R. (2014) · Korean Journal of Pediatrics · doi:10.3345/kjp.2014.57.10.425 · Cited by 52
Salivary estradiol as a surrogate marker for serum estradiol in assisted reproduction treatment
Fiers, T., Dielen, C., Somers, S., Kaufman, J., & Gerris, J. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.09.016 · Cited by 42
Al‐Naamani, N., Krowka, M. J., Forde, K. A., Krok, K. L., Feng, R., Heresi, G. A., Dweik, R. A., Bartolome, S., Bull, T., Roberts, K. E., et al. (2020) · Hepatology · doi:10.1002/hep.31314 · Cited by 47
“This is consistent with previous literature given that LC-MS/MS provides a precise assessment of 17β-estradiol whereas immunoassay has some cross-reactivity with estrone and, to a lesser degree, with other estrogenic hormones,(41-43) which may actually more meaningfully capture the full extent of aromatase activity.”
ResultPrasad, S., Lassetter, B., Welker, K. M., & Mehta, P. H. (2019) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2019.104373 · Cited by 41
Approach to the Patient With Glucocorticoid-induced Adrenal Insufficiency
Borresen, S. W., Klose, M., Glintborg, D., Watt, T., Andersen, M., & Feldt‐Rasmussen, U. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac151 · Cited by 48
Burgess, E. A., Hunt, K. E., Kraus, S. D., & Rolland, R. M. (2017) · General and Comparative Endocrinology · doi:10.1016/j.ygcen.2017.07.026 · Cited by 42
Vogg, N., Kurlbaum, M., Deutschbein, T., Gräsl, B., Fassnacht, M., & Kroiss, M. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab056 · Cited by 38
“Dex in DST samples has historically been measured by radioimmunoassay (16–19) which is associated with lack of analytical specificity and cross-reactivity with structurally similar compounds (20, 21).”
BackgroundOccurrence and reproductive roles of hormones in seminal plasma
Vítků, J., Kolátorová, L., & Hampl, R. (2017) · Basic and Clinical Andrology · doi:10.1186/s12610-017-0062-y · Cited by 42
“In addition to endogenous structurally related molecules, some drugs (such as anabolic steroids and herbal medications) and natural products can cross-react with the antibody and thus increase the apparent analyte concentration [112].”
Ovarian hormones modulate endothelin A and B receptor expression
Gohar, E. Y., Yusuf, C., & Pollock, D. M. (2016) · Life Sciences · doi:10.1016/j.lfs.2016.01.010 · Cited by 41
“cial assay with a number of related steroid compounds already existing in serum samples [22].”
How low can you go? Analytical performance of five automated testosterone immunoassays
La'ulu, S. L., Kalp, K. J., & Straseski, J. A. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.05.008 · Cited by 37
Predictors of Steroid Hormone Concentrations in Early Pregnancy: Results from a Multi-Center Cohort
Barrett, E. S., Mbowe, O. B., Thurston, S. W., Butts, S. F., Wang, C., Nguyen, R. H. N., Bush, N. R., Redmon, J. B., Sheshu, S., Swan, S. H., et al. (2019) · Maternal and Child Health Journal · doi:10.1007/s10995-018-02705-0 · Cited by 36
Advances in Clinical Mass Spectrometry
French, D. (2016) · Advances in clinical chemistry · doi:10.1016/bs.acc.2016.09.003 · Cited by 52
England-Mason, G., Kimber, M., Khoury, J. E., Atkinson, L. R., MacMillan, H. L., & González, A. (2017) · Hormones and Behavior · doi:10.1016/j.yhbeh.2017.07.007 · Cited by 47
Glynne, S., Reisel, D., Kamal, A., Neville, A. M., McColl, L., Lewis, R., & Newson, L. R. (2024) · Menopause The Journal of The North American Menopause Society · doi:10.1097/gme.0000000000002459 · Cited by 38
Advances in Bioanalytical Techniques to Measure Steroid Hormones in Serum
French, D. (2016) · Bioanalysis · doi:10.4155/bio-2015-0025 · Cited by 38
Improving Science by Overcoming Laboratory Pitfalls With Hormone Measurements
Hillebrand, J. J., Wickenhagen, W. V., & Heijboer, A. C. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa923 · Cited by 34
“For other steroid hormones, similar cross-reactivity issues occur (7-11).”
BackgroundZha, L., Li, J., Krishnan, S. M., Brennan, M. R., Zhang, Y. V., Povse, P., Kerlin, R., Shively, K., Oleksik, F., Williams, J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.04.003 · Cited by 34
Measuring estrogens in women, men, and children: Recent advances 2012–2017
Smy, L., & Straseski, J. A. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.05.014 · Cited by 30
Steroid profiling in the diagnosis of mild and overt Cushing’s syndrome
Athimulam, S., Grebe, S. K. G., & Bancos, I. (2021) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2021.101488 · Cited by 34
“Finally, the automated assays also do not separate unconjugated hormones from conjugated hormones and hormone metabolites(51, 52) Another limitation of competitive immunoassays is their limited dynamic range of only 1–2 log.”
BackgroundFalsely elevated serum oestradiol due to exemestane therapy
Mandić, S., Kratzsch, J., Mandić, D., Debeljak, Ž., Lukić, I., Horvat, V., Gaudl, A., & Šerić, V. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563216674031 · Cited by 33
“Recently published data, obtained by Krasowski et al.15 indicated that AIs, including exemestane, do not cause any detectable cross-reaction in spiked samples measured using the Roche E2 kit for Elecsys and Modular E170 analyzers.”
Analytical bias of automated immunoassays for six serum steroid hormones assessed by LC-MS/MS
Debeljak, Ž., Marković, I., Šerić, V., Horvat, V., Mandić, S., Mandić, D., Lukić, I., & Pavela, J. (2020) · Biochemia Medica · doi:10.11613/bm.2020.030701 · Cited by 29
“Problems with the analytical bias of serum immunoassays for steroid quantification still persist: there is a long-lasting demand for more accurate methods and techniques that are less complex in terms of manual sample preparation than GC-MS (1-5).”
BackgroundMethodInfluentialAnalytical Methods for the Determination of Neuroactive Steroids
Kaleta, M., Oklešťková, J., Novák, O., & Strnad, M. (2021) · Biomolecules · doi:10.3390/biom11040553 · Cited by 29
“IA saliva, serum glucocorticoids, mineralocorticoids [22] serum, CSF androgens, progestins, estrogens [35] serum androgens [39] plasma estrogens [44] plasma, serum androgens, progestins, estrogens, glucocorticoids [54] serum androgens [55] serum androgens [56] plasma androgens, estrogens [57] serum androgens, estrogen…”
BackgroundMethodKempe, H., & Kempe, M. (2022) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2022.02.035 · Cited by 26
Gillan, L., & Jansson, E. (2022) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac7187 · Cited by 26
“This result is superior to typical enzymelinked immunosorbent assays (ELISA), which commonly fail to differentiate cortisol from hormones such as prednisolone [58, 59].”
Reschly-Krasowski, J. M., & Krasowski, M. D. (2018) · Academic Pathology · doi:10.1177/2374289518811797 · Cited by 24
“This approach has been used to rationalize and predict crossreactivity of immunoassays used in UDT,(14,16,43,46) therapeutic drug monitoring,(47) and endocrinology.(48) Regardless of approach, it would help to have more consistency in crossreactivity testing, placing priority on compounds known to be cross-reactive in…”
Self-citationvan Winden, L. J., Kok, M., Acda, M., Dezentje, V., Linn, S., Shi, R.-Z., & van Rossum, H. H. (2021) · Journal of Chromatography B · doi:10.1016/j.jchromb.2021.122563 · Cited by 23
Garmes, H. M., Boguszewski, C. L., Miranda, P. A. C., Martins, M. R. A., Correa‐Silva, S. R., Abucham, J., Musolino, N. R. D. C., Vilar, L., Portari, L. H. C., Gadelha, M. R., et al. (2021) · Archives of Endocrinology and Metabolism · doi:10.20945/2359-3997000000335 · Cited by 32
“These drugs may cross-react with cortisol measurement assays at different extents, and the duration of their suppression on the hypothalamicpituitary-adrenal axis lacks consensus in the literature (54,55).”
Kehmeier, M. N., Bedell, B. R., Cullen, A. E., Khurana, A., D’Amico, H. J., Henson, G. D., & Walker, A. E. (2022) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00369.2022 · Cited by 26
Adrenal Cushing Syndrome Diagnosed During Pregnancy: Successful Medical Management With Metyrapone
Azzola, A., Eastabrook, G. D. M., Matsui, D. M., Berberich, A. J., Tirona, R. G., Gray, D., Gallego, P., & Uum, S. H. M. V. (2020) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaa167 · Cited by 23
“6%, but indicated to be clinically relevant in patients with 11β-hydroxylase deficiency or following metyrapone challenge [14].”
BackgroundDufour, P., Courtois, J., Seynaeve, Y., Peeters, S. D., Goff, C. M. L., Cavalier, E., & Ponthier, J. (2021) · Research in Veterinary Science · doi:10.1016/j.rvsc.2021.03.014 · Cited by 23
“…knowledge about endocrinology of the pregnancy in horse is potentially biased by this lack of specificity and accuracy and it should be updated and refined by the use of a more specific and accurate technology (Senger and Phillip, 1997; Krasowski et al., 2014; Raeside, 2017; Wudy et al., 2018).”
InfluentialFraissinet, F., Pereira, T., Violin, A., Feugray, G., Bach‐Ngohou, K., & Brunel, V. (2022) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2022.12.004 · Cited by 22
“They are adapted to emergency situations and allow a rapid rendering of results with low volumes of serum, but sometimes lack specificity due to the cross-reactivity of antibodies with other endogenous or exogenous steroids [3].”
Progesterone Analysis in Canine Breeding Management
Conley, A. J., Gonzales, K., Erb, H. N., & Christensen, B. W. (2023) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/j.cvsm.2023.05.007 · Cited by 25
Legacki, E. L., Scholtz, E. L., Ball, B. A., Esteller‐Vico, A., Stanley, S. D., & Conley, A. J. (2019) · Equine Veterinary Journal · doi:10.1111/evj.13109 · Cited by 23
Towards Improved Steroid Hormone Analysis: The Shift from Immunoassays to Mass Spectrometry
Deng, B., Bi, M., Zheng, Y., Hussain, D., Yang, S., & Chen, D. (2024) · Journal of Analysis and Testing · doi:10.1007/s41664-024-00326-x · Cited by 23
“Moreover, anabolic steroids also exhibit cross-reactivity with steroid hormone assays, including norethindrone and meth-yltestosterone in testosterone immunoassays, mifepristone in testosterone, and estradiol immunoassays, prednisolone and 6-methylprednisolone in cortisol immunoassays [44].”
Fourkala, E.-O., Blyuss, O. B., Field, H. P., Gunu, R., Ryan, A., Barth, J. H., Jacobs, I. J., Zaikin, A. A., Dawnay, A., & Menon, U. (2016) · Steroids · doi:10.1016/j.steroids.2016.04.003 · Cited by 20
“In the last few years, assays with an organic extraction step and mass spectrometry are emerging as the ‘gold standard’ [19].”
Xu, W., Li, H., Guan, Q., Shen, Y., & Cheng, L. (2016) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22102 · Cited by 19
Sakai, H., Nagao, H., Sakurai, M., Okumura, T., Nagai, Y., Shikuma, J., Ito, R., Imazu, T., Miwa, T., & Odawara, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138864 · Cited by 19
“For measuring steroid hormones [19] and vitamin D (particularly 25-hydroxyvitamin D), the specificity of the currently used immunoassay is markedly low owing to cross-reactivity.”
Rossi, C., Cicalini, I., Verrocchio, S., Dalmazi, G. D., Federici, L., & Bucci, I. (2020) · Biomedicines · doi:10.3390/biomedicines8090314 · Cited by 21
A Contemporary Approach to the Diagnosis and Management of Adrenal Insufficiency
Charoensri, S., & Auchus, R. J. (2024) · Endocrinology and Metabolism · doi:10.3803/enm.2024.1894 · Cited by 28
“These medications must be withheld for at least 24 hours prior to testing, as hydrocortisone is cortisol, and prednisolone still cross-reacts in monoclonal immunoassays but not LC-MS/MS cortisol assays [23].”
Dimastrogiovanni, G., Fernandes, D., Bonastre, M., & Porte, C. (2015) · Aquatic Toxicology · doi:10.1016/j.aquatox.2015.05.018 · Cited by 18
Manickam, P., Arizaleta, F., Muneeswaran, G., & Bhansali, S. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.0101705jes · Cited by 18
“9 An important finding from this study is the increasing H-bond strength and binding energy with increasing number of double bonds around the carbonyl group at C 3 , which could be used as a basic clue to design a specific imprinted polymers.”
Holzhauer, C. G., Wemm, S., Wulfert, E., & Cao, Z. T. (2019) · Addictive Behaviors · doi:10.1016/j.addbeh.2019.106146 · Cited by 21
“Many psychological studies have relied on immunoassay techniques to measure salivary hormone levels, despite increasing evidence from the clinical chemistry field demonstrating that steroid hormones are prone to cross-reactivity between compounds of similar molecular structure (Krasowski et al., 2014; Miller, Plessow,…”
BackgroundLood, Y., Aardal, E., Ahlner, J., Ärlemalm, A., Björn Carlsson, A., Ekman, B., Wahlberg, J., & Josefsson, M. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113823 · Cited by 18
Emerging trends in wearable and non-invasive cortisol sensing technologies – a review
Balasamy, S., Atchudan, R., Arya, S. K., & Sundramoorthy, A. K. (2025) · Journal of Materials Chemistry B · doi:10.1039/d5tb01519g · Cited by 22
Krasowski, M. D., Ford, B. A., Klutts, J. S., Jensen, C. S., Briggs, A. S., Robinson, R. A., Bruch, L. A., & Karandikar, N. J. (2017) · Academic Pathology · doi:10.1177/2374289517722152 · Cited by 16
Self-citationOral estrogen leads to falsely low concentrations of estradiol in a common immunoassay
Cirrincione, L. R., Crews, B. O., Dickerson, J. A., Krasowski, M. D., Rongitsch, J., Imborek, K. L., Goldstein, Z., & Greene, D. N. (2022) · Endocrine Connections · doi:10.1530/ec-21-0550 · Cited by 17
Self-citationGlucocorticoid production in the thymus and brain: Immunosteroids and neurosteroids
Salehzadeh, M., & Soma, K. K. (2021) · Brain Behavior & Immunity - Health · doi:10.1016/j.bbih.2021.100352 · Cited by 21
Salivary cortisol measurement in horses: immunoassay or LC-MS/MS?
Sauer, F. J., Gerber, V., Frei, S., Bruckmaier, R. M., & Groessl, M. (2020) · Domestic Animal Endocrinology · doi:10.1016/j.domaniend.2020.106445 · Cited by 16
Lanfermeijer, M., van Winden, L. J., Starreveld, D. E. J., Razab-Sekh, S., van Faassen, M. H. J. R., Bleiker, E. M. A., & van Rossum, H. H. (2024) · Analytical Biochemistry · doi:10.1016/j.ab.2024.115496 · Cited by 16
Gomila, I., Leciñena, M. Á., Elorza, M. Á., Pastor, Y., Frías, L. S., Pieras, M. Á. S., Puiguriguer, J., & Martín, B. B. (2019) · Journal of Analytical Toxicology · doi:10.1093/jat/bkz026 · Cited by 14
Ivanova, N. M., Nenchovska, Z., Atanasova, M., Laudon, M., Mitreva, R., & Tchekalarova, J. D. (2021) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-021-01100-8 · Cited by 16
Retrospective Approach to Evaluate Interferences in Immunoassay.
Warade, J. P. (2017) · PubMed Central · Cited by 14
Sala, L. L., Tagliabue, E., Vieira, E. C., Pontiroli, A. E., & Folli, F. B. (2021) · Cardiovascular Diabetology · doi:10.1186/s12933-021-01310-w · Cited by 16
“Urinary cortisol levels were also assayed [28, 29].”
Mahlab‐Guri, K., Asher, I., & Sthoeger, Z. M. (2023) · Swiss Medical Weekly · doi:10.57187/smw.2023.40025 · Cited by 13
Gjorgoska, M., & Rižner, T. L. (2024) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2024.106578 · Cited by 16
“Measurement of endogenous steroid hormones in the blood often presents a clinical challenge owing to the very low concentrations (for example, picomolar range) and structural similarity of endogenous hormones and metabolites [7 – 9].”
BackgroundThe importance of estradiol measurement in patients undergoing in vitro fertilization
Garnett, E. R., Bruno-Gaston, J., Cao, J., Zarutskie, P. W., & Devaraj, S. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.09.021 · Cited by 13
Testosterone analysis in prostate cancer patients
van Winden, L. J., & van Rossum, H. H. (2022) · Advances in clinical chemistry · doi:10.1016/bs.acc.2021.07.007 · Cited by 15
Blackwell, B. R., & Ankley, G. T. (2020) · Journal of Chromatography B · doi:10.1016/j.jchromb.2020.122513 · Cited by 12
“these assays have demonstrated cross-reactivity with structurally similar compounds, which can lead to discrepancies in assay results [18, 19].”
Backgroundvan Winden, L. J., Lanfermeijer, M., Heijboer, A. C., van Tellingen, O., Bergman, A. M., van der Poel, H. G., Jonker, N., & van Rossum, H. H. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.06.030 · Cited by 11
Shayegan, B., Pouliot, F., So, A., Fernandes, J. R., & Macri, J. (2017) · Canadian Urological Association Journal · doi:10.5489/cuaj.4539 · Cited by 11
Hammami, M. M., Duaiji, N., Mutairi, G., Aklabi, S., Qattan, N., Abouzied, M., & Sous, M. W. (2015) · BMC Cancer · doi:10.1186/s12885-015-1620-3 · Cited by 11
Karaman, C., Aydemir, M., & Karaman, O. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118687 · Cited by 15
Boddu, S. K., & Madhavan, S. (2017) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2017-0166 · Cited by 10
Chemical similarity of molecules with physiological response
Redžepović, I., & Furtula, B. (2022) · Molecular Diversity · doi:10.1007/s11030-022-10514-5 · Cited by 10
“Also, the authors in [8] have shown that compounds producing cross-reactivity in steroid hormone immunoassays have a high degree of structural similarity to the target hormone.”
BackgroundImproving LC-MS/MS measurements of steroids with differential mobility spectrometry
Chai, Y., Grebe, S. K. G., & Maus, A. D. (2023) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2023.10.001 · Cited by 11
“However, due to the shared cholesterol backbone structure, there is a large amount of structural and chemical similarity among steroids, leading to a tendency for interference and cross-reactivity [2 – 4].”
BackgroundGunn, H. M., Rinne, I., Emilsson, H., Gabriel, M. A., Maguire, A., & Steinbeck, K. S. (2016) · Journal of Adolescent and Young Adult Oncology · doi:10.1089/jayao.2016.0007 · Cited by 12
Kunze, M., Wirthgen, E., Walz, C., Spitschak, M., Brenmoehl, J., Vanselow, J., Schwerin, M., Wimmers, K., & Hoeflich, A. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.10.010 · Cited by 10
Comparisons between commercial salivary testosterone enzyme-linked immunosorbent assay kits
Andersson, C., Bergquist, J., Theodorsson, E., & Ström, J. O. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1339231 · Cited by 10
“Furthermore, the different antibodies may react differently to matrix factors, including pH in saliva [9,10].”
van Helden, J., & Weiskirchen, R. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.09.009 · Cited by 10
Ong, M. L. Y., Green, C. G., Rowland, S. N., & Heaney, L. M. (2023) · Analytical Science Advances · doi:10.1002/ansa.202300003 · Cited by 9
“However, it is well known that the major limitation of immunoassay measurements of steroid hormones is the interference caused by structurally similar compounds and their metabolites, 145 with significant similarities between steroid hormones due to them all being derived from cholesterol.”
Sasaki, N., Oo, T., Yasuda, Y., Ichise, T., Nagata, N., Yokoyama, N., Sasaoka, K., Morishita, K., Nakayama, S. M. M., Ishizuka, M., et al. (2021) · Journal of Veterinary Medical Science · doi:10.1292/jvms.21-0406 · Cited by 12
“Meanwhile, the major limitation of immunoassay is lack of the specificity due to cross reactivity with structurally similar compounds [ 16].”
Congenital Hypopituitarism in Neonates
Cherella, C. E., & Cohen, L. E. (2018) · NeoReviews · doi:10.1542/neo.19-12-e742 · Cited by 9
Discordance between testosterone measurement methods in castrated prostate cancer patients
Rouleau, M., Lemire, F., Déry, M., Thériault, B., Dubois, G., Fradet, Y., Toren, P., Guillemette, C., Lacombe, L., Klotz, L. H., et al. (2019) · Endocrine Connections · doi:10.1530/ec-18-0476 · Cited by 9
Glucocorticoid signature of preterm infants developing bronchopulmonary dysplasia
Romijn, M., Onland, W., van Keulen, B. J., Heijboer, A. C., Rotteveel, J., van Kaam, A. H., & Finken, M. J. J. (2023) · Pediatric Research · doi:10.1038/s41390-023-02690-3 · Cited by 8
Mathy, A., Wessner, B., Haider, P., Tschan, H., & Triska, C. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1305895 · Cited by 9
Reliable in-house LC-MS/MS method for steroid hormone analysis: Validations and comparisons
He, Y., Luo, M., Hu, J., Li, Q., Yang, S., Zhen, Q., & Ma, L. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120610 · Cited by 8
Sait, S. T. L., Survilienė, V., Jüssi, M., González, S. V., Ciesielski, T. M., Jenssen, B. M., & Asimakopoulos, A. G. (2022) · Talanta · doi:10.1016/j.talanta.2022.124109 · Cited by 9
Kline, G. A., & Chin, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803412-5.00005-7 · Cited by 10
van Winden, L. J., Vermeulen, R. F. M., van der Noort, V., Gaarenstroom, K. N., Kenter, G. G., Zanten, M. M. A. B.-V., Korse, C. M., van Beurden, M., & van Rossum, H. H. (2022) · Journal of the Endocrine Society · doi:10.1210/jendso/bvac069 · Cited by 8
“This limitation has been extensively described in literature and emphasizes substantial discrepancies when serum testosterone is measured in women [27-31].”
Tiwari, R. V., Lajkosz, K., Berjaoui, M. B., Qaoud, Y., Kenk, M., Woffendin, C., Caron, P., Guillemette, C., & Fleshner, N. E. (2022) · Urologic Oncology Seminars and Original Investigations · doi:10.1016/j.urolonc.2022.03.011 · Cited by 7
The Mechanisms of Anabolic Steroids, Selective Androgen Receptor Modulators and Myostatin Inhibitors
Park, J., Mcllvain, V., Rosenberg, J., Donovan, L., Desai, P., & Kim, J. Y. (2022) · The Korean Journal of Sports Medicine · doi:10.5763/kjsm.2022.40.2.67 · Cited by 9
Metadata
- Authors
- Krasowski, M. D., Drees, D., Morris, C. S., Maakestad, J., Blau, J. L., & Ekins, S.
- Affiliations
- University of Iowa Hospitals and Clinics (US)
- University of Michigan (US)
- Corresponding author
- Krasowski, Matthew D
- Venue
- BMC Clinical Pathology
- Published
- 2014-07-14
- Volume
- 14
- Issue
- 1
- Pages
- 33-33
- ISSN
- 1472-6890 (ISSN-L)
- PMC
- PMC4112981
- OpenAlex
- W2043223954
- Semantic Scholar
- a9545d47c49699a6c80a80bc0eb4df29b3fff7b7
- Cited by
- 212
- References
- 65
- Citations by year
- 2026: 18 · 2025: 27 · 2024: 25 · 2023: 17 · 2022: 23 · 2021: 18 · 2020: 16 · 2019: 18 · 2018: 11 · 2017: 18 · 2016: 15 · 2015: 5 · 2014: 1
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- BMC Clinical Pathology (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
- Keywords
- cross-reactivity, immunoassay interference, cortisol, testosterone, dehydroepiandrosterone sulfate, estradiol, progesterone, 21-deoxycortisol, 11-deoxycortisol, 21-hydroxylase deficiency, 11beta-hydroxylase deficiency, anabolic steroids, synthetic glucocorticoids, norethisterone, false positives, structural similarity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.