Cited by 34Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyHeart Rate Variability and Autonomic Control

Estimation of cardiac output and systemic vascular resistance using a multivariate regression model with features selected from the finger photoplethysmogram and routine cardiovascular measurements

Open access
Lee, Qim Y, Redmond, Stephen J, Chan, Gregory SH, Middleton, Paul M, Steel, Elizabeth, Malouf, Philip, Critoph, Cristopher, Flynn, Gordon +2 more·2013·BioMedical Engineering OnLine

Abstract

BACKGROUND: Cardiac output (CO) and systemic vascular resistance (SVR) are two important parameters of the cardiovascular system. The ability to measure these parameters continuously and noninvasively may assist in diagnosing and monitoring patients with suspected cardiovascular diseases, or other critical illnesses. In this study, a method is proposed to estimate both the CO and SVR of a heterogeneous cohort of intensive care unit patients (N=48). METHODS: Spectral and morphological features were extracted from the finger photoplethysmogram, and added to heart rate and mean arterial pressure as input features to a multivariate regression model to estimate CO and SVR. A stepwise feature search algorithm was employed to select statistically significant features. Leave-one-out cross validation was used to assess the generalized model performance. The degree of agreement between the estimation method and the gold standard was assessed using Bland-Altman analysis. RESULTS: The Bland-Altman bias ±precision (1.96 times standard deviation) for CO was -0.01 ±2.70 L min-1 when only photoplethysmogram (PPG) features were used, and for SVR was -0.87 ±412 dyn.s.cm-5 when only one PPG variability feature was used. CONCLUSIONS: These promising results indicate the feasibility of using the method described as a non-invasive preliminary diagnostic tool in supervised or unsupervised clinical settings.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1475-925x-12-19

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cardiac output has been estimated from pulse wave shape and low-frequency PPG variations.

    “Cardiac output, monitored in peri-operative and critical care settings, has been estimated from pulse wave shape and low-frequency PPG variations”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [178]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Draper NR Smith H Pownell E Applied Regression Analysis, Volume 3 1966 New York: Wiley

Cited by

Sorted by citations

Authors
Lee, Q. Y., Redmond, S. J., Chan, G. S., Middleton, P. M., Steel, E., Malouf, P., Critoph, C., Flynn, G., O’Lone, E., & Lovell, N. H.
Affiliations
  • UNSW Sydney (AU)
  • The University of Sydney (AU)
  • Prince of Wales Hospital (AU)
Corresponding author
Lee, Qim Y
Venue
BioMedical Engineering OnLine
Published
2013
Volume
12
Issue
1
Pages
19
ISSN
1475-925X (ISSN-L)
OpenAlex
W2136022512
Cited by
34
References
27
Citations by year
2026: 1 · 2025: 4 · 2024: 1 · 2023: 1 · 2022: 6 · 2021: 1 · 2020: 1 · 2019: 4 · 2018: 2 · 2017: 6 · 2016: 2 · 2015: 4 · 2014: 1
FWCI
1.29
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BioMedical Engineering OnLine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
cardiac output estimation, systemic vascular resistance, noninvasive hemodynamic monitoring, multivariate regression, feature selection, intensive care unit patients, mean arterial pressure, heart rate
MeSH terms
Aged, Blood Pressure, Cardiac Output, Cardiovascular Diseases, Cardiovascular System, Female, Fingers, Heart Rate, Humans, Male, Monitoring, Physiologic, Regression Analysis, Signal Processing, Computer-Assisted, Vascular Resistance, Reproducibility of Results, Multivariate Analysis, Photoplethysmography, Arterial Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review