A comparative analysis of swallowing accelerometry and sounds during saliva swallows
Open accessThe DOI matches its Crossref record; 50 of the 52 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accelerometry (the measurement of vibrations) and auscultation (the measurement of sounds) are both non-invasive techniques that have been explored for their potential to detect abnormalities in swallowing. The differences between these techniques and the information they capture about swallowing have not previously been explored in a direct comparison. METHODS: In this study, we investigated the differences between dual-axis swallowing accelerometry and swallowing sounds by recording data from adult participants and calculating a number of time and frequency domain features. During the experiment, 55 participants (ages 18-65) were asked to complete five saliva swallows in a neutral head position. The resulting data was processed using previously designed techniques including wavelet denoising, spline filtering, and fuzzy means segmentation. The pre-processed signals were then used to calculate 9 time, frequency, and time-frequency domain features for each independent signal. Wilcoxon signed-rank and Wilcoxon rank-sum tests were utilized to compare feature values across transducers and patient demographics, respectively. RESULTS: In addition to finding a number of features that varied between male and female participants, our statistical analysis determined that the majority of our chosen features were statistically significantly different across the two sensor methods and that the dependence on within-subject factors varied with the transducer type. However, a regression analysis showed that age accounted for an insignificant amount of variation in our signals. CONCLUSIONS: We conclude that swallowing accelerometry and swallowing sounds provide different information about deglutition despite utilizing similar transduction methods. This contradicts past assumptions in the field and necessitates the development of separate analysis and processing techniques for swallowing sounds and vibrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“previous work has shown little significant effect of age on cervical auscultation signals even for large age differences [28].”
From A statistical analysis of cervical auscultation signals from adults with unsafe airway protection (2016) · cites this paper as [28]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“when compared to their values for safe swallows, the values of many of the features corresponding to unsafe swallows are closer to the values found in a previous study corresponding to safe swallows made by healthy subjects [28].”
From A statistical analysis of cervical auscultation signals from adults with unsafe airway protection (2016) · cites this paper as [28]
In the citing paper
“Past studies have also demonstrated how the patient’s sex and the viscosity of the bolus affect cervical auscultation signals, so the independent effects of these variables were also analyzed in this study to determine if their effects remained constant [27, 28].”
From A statistical analysis of cervical auscultation signals from adults with unsafe airway protection (2016) · cites this paper as [28]
In the citing paper
“Past studies have also demonstrated how the patient’s sex and the viscosity of the bolus affect cervical auscultation signals, so the independent effects of these variables were also analyzed in this study to determine if their effects remained constant [27, 28].”
From A statistical analysis of cervical auscultation signals from adults with unsafe airway protection (2016) · cites this paper as [28]
In the citing paper
“our sex-based contrasts match our previous work (Dudik, JM, Kurosu, A, Coyle, JL, Sejdić, E: The effects of dysphagia on swallowing sounds and vibrations in adults, under review) and [28], with males demonstrating higher frequency components and greater kurtosis than female counterparts.”
From A statistical analysis of cervical auscultation signals from adults with unsafe airway protection (2016) · cites this paper as [28]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vetterli, M., & Kovačević, J. (1995) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 3,205
On the Complexity of Finite Sequences
Lempel, A., & Ziv, J. (1976) · IEEE Transactions on Information Theory · doi:10.1109/tit.1976.1055501 · Cited by 2,717 · cited 1×
“While the complexity of both signals is already quite low, this indicates that our discretized A-P accelerometer data can be compressed further without losing information about the signal [45].”
BackgroundThe Cambridge Dictionary of Statistics
SRJ, & Everitt, B. S. (1999) · Journal of the American Statistical Association · doi:10.2307/2670205 · Cited by 940 · cited 3×
“This means that swallows produce vibrations in the anterior-posterior direction that slowly increase in intensity before decreasing much faster, whereas swallowing sounds do not follow such a consistent pattern [35].”
BackgroundMethodGray, H., Gray, H., & Lewis, W. H. (1918) · Lea & Febiger eBooks · doi:10.5962/bhl.title.20311 · Cited by 840
The Cambridge Dictionary of Statistics: Fourth Edition
Everitt, B. S., & Skrondal, A. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511779633 · Cited by 820
Time–frequency feature representation using energy concentration: An overview of recent advances
Sejdić, E., Djurović, I., & Jiang, J. (2009) · Digital Signal Processing · doi:10.1016/j.dsp.2007.12.004 · Cited by 756
Self-citationComplications and Outcome After Acute Stroke: Does Dysphagia Matter?
Smithard, D. G., O'Neill, P. A., Park, C., Morris, J., Wyatt, R., England, R., & Martin, D. F. (1996) · Stroke · doi:10.1161/01.str.27.7.1200 · Cited by 734 · cited 2×
“It commonly develops as a component of neurological conditions, particularly trauma or stroke [1,2].”
BackgroundA new autoregressive spectrum analysis algorithm
Marple, L. (1980) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1980.1163429 · Cited by 433 · cited 1×
“At an earlier date, the accelerometer’s baseline output was recorded and modified covariance auto-regressive modelling was used to characterize the device noise [29,30].”
MethodInterpretation of the Lempel-Ziv Complexity Measure in the Context of Biomedical Signal Analysis
Aboy, M., Hornero, R., Abasolo, D., & Alvarez, D. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883696 · Cited by 407 · cited 1×
“This allowed us to calculate the Lempel-Ziv complexity as C = k log100 n n (3) wherek is the number of unique sequences in the decomposed signal and n is the pattern length [36].”
MethodPreliminary observations on the effects of age on oropharyngeal deglutition
Tracy, J. F., Logemann, J. A., Kahrilas, P. J., Jacob, P., Kobara, M., & Krugler, C. (1989) · Dysphagia · doi:10.1007/bf02407151 · Cited by 334
Research works printed but not linked: 2
- Analog Devices ADXL322: Small and Thin 2g Accelerometer Data Sheet 2005 Norwood, MA Analog Devices
- AKG Acoustics MicroMic, The Original: C411 1991 Wien, AT AKG Acoustics
Cited by
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Dudik, J. M., Coyle, J. L., & Sejdic, E. (2015) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2408615 · Cited by 86
“maintain a “pure” signal [21], [49], [51], [65], [66], [83], [86], [90], others place it as high as 30 Hz or more in order to eliminate motion artifacts and other low-frequency noise [39], [42], [44],”
InfluentialSelf-citationDudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.01.007 · Cited by 76
“A third technique which strikes a balance between computation requirements and accuracy and has been used to automatically segment swallowing vibrations successfully is the k-means clustering technique [36,37,18,19].”
BackgroundMethodResultInfluentialSelf-citationAutomatic hyoid bone detection in fluoroscopic images using deep learning
Zhang, Z., Coyle, J. L., & Sejdić, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-30182-6 · Cited by 64
Self-citationDysphagia and its effects on swallowing sounds and vibrations in adults
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0501-9 · Cited by 58
“The age of the subjects was not utilized as a variable for any of our statistical tests since previous work has shown little significant effect of age on cervical auscultation signals even for large age differences [41].”
Self-citation
Metadata
- Authors
- Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Sejdić, Ervin
- Venue
- BioMedical Engineering OnLine
- Published
- 2015-01-12
- Volume
- 14
- Issue
- 1
- Pages
- 3-3
- ISSN
- 1475-925X (ISSN-L)
- PMC
- PMC4361156
- OpenAlex
- W2143014063
- Cited by
- 72
- References
- 52
- Citations by year
- 2026: 1 · 2025: 9 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 10 · 2020: 8 · 2019: 2 · 2018: 11 · 2017: 6 · 2016: 7 · 2015: 3
- FWCI
- 19.74
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- BioMedical Engineering OnLine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- D-Scholarship@Pitt (University of Pittsburgh) (acceptedVersion)
- Funders
- University of Pittsburgh (UL1TR000005, UL1RR024153, RR024153)
- National Institutes of Health (UL1TR000005, RR024153, TR000005)
- National Center for Research Resources (UL1RR024153)
- National Center for Advancing Translational Sciences
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD074819)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
- Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Keywords
- swallowing, accelerometry, swallowing sounds, auscultation, time-frequency features, sex differences, wavelet denoising
- MeSH terms
- Adolescent, Adult, Aged, Aging, Algorithms, Deglutition, Female, Humans, Male, Middle Aged, Saliva, Sex Characteristics, Signal Processing, Computer-Assisted, Sound, Transducers, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.