Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: As a continuation of our earlier work, we present in this study a Kalman filtering based algorithm for the elimination of motion artifacts present in Near Infrared spectroscopy (NIR) measurements. Functional NIR measurements suffer from head motion especially in real world applications where movement cannot be restricted such as studies involving pilots, children, etc. Since head movement can cause fluctuations unrelated to metabolic changes in the blood due to the cognitive activity, removal of these artifacts from NIR signal is necessary for reliable assessment of cognitive activity in the brain for real life applications. METHODS: Previously, we had worked on adaptive and Wiener filtering for the cancellation of motion artifacts in NIR studies. Using the same NIR data set we have collected in our previous work where different speed motion artifacts were induced on the NIR measurements we compared the results of the newly proposed Kalman filtering approach with the results of previously studied adaptive and Wiener filtering methods in terms of gains in signal to noise ratio. Here, comparisons are based on paired t-tests where data from eleven subjects are used. RESULTS: The preliminary results in this current study revealed that the proposed Kalman filtering method provides better estimates in terms of the gain in signal to noise ratio than the classical adaptive filtering approach without the need for additional sensor measurements and results comparable to Wiener filtering but better suitable for real-time applications. CONCLUSIONS: This paper presented a novel approach based on Kalman filtering for motion artifact removal in NIR recordings. The proposed approach provides a suitable solution to the motion artifact removal problem in NIR studies by combining the advantages of the existing adaptive and Wiener filtering methods in one algorithm which allows efficient real time application with no requirement on additional sensor measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 3×
“Both techniques have been widely used for noise reduction in many biomedical, communication, speech processing applications [ 4-8 ].”
BackgroundMethodInfluential
Cited by
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Brigadoi, S., Ceccherini, L., Cutini, S., Scarpa, F., Scatturin, P., Selb, J., Gagnon, L., Boas, D. A., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.082 · Cited by 557
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
“In cases where real motion artifact contaminated NIRS data has been used, the utility of a correction technique has been quantified using some measure of improvement in signal-to-noise ratio of the corrected NIRS timecourse (Izzetoglu et al., 2010; Scholkmann et al., 2010; Molavi and Dumont, 2012).”
BackgroundMethodInfluentialChen, W.-L., Wagner, J., Heugel, N., Sugar, J., Lee, Y.-W., Conant, L., Malloy, M., Heffernan, J., Quirk, B., Zinos, A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00724 · Cited by 382
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
Barker, J. W., Aarabi, A., & Huppert, T. J. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001366 · Cited by 337
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Neuroimaging of Mobility in Aging: A Targeted Review
Holtzer, R., Epstein, N., Mahoney, J. R., Izzetoglu, M., & Blumen, H. M. (2014) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glu052 · Cited by 304
Self-citationQuaresima, V., Bisconti, S., & Ferrari, M. (2012) · Brain and Language · doi:10.1016/j.bandl.2011.03.009 · Cited by 276
Scarapicchia, V., Brown, C., Mayo, C., & Gawryluk, J. R. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00419 · Cited by 253
Online fronto-cortical control of simple and attention-demanding locomotion in humans
Holtzer, R., Mahoney, J. R., Izzetoglu, M., Wang, C., England, S., & Verghese, J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.002 · Cited by 208
Self-citationA review on spectral data preprocessing techniques for machine learning and quantitative analysis
Yan, C. (2025) · iScience · doi:10.1016/j.isci.2025.112759 · Cited by 193
“Time update propagates the prior state estimate ̂ x k (cid:0) 1 and error covariance P k (cid:0) 1 forward equations 174,175 : { State prediction: 98) Here, x (cid:0) k and P (cid:0) k represent the predicted state and error covariance, respectively, with A as the state transition matrix and Q as…”
Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
“…et al 2006c), PCA truncation (Wilcox et al 2005), local and global assessment of the variance (Holper et al 2009, White et al 2009), ICA over co-located channels (Robertson et al 2010), Kalman filtering (Izzetoglu et al 2010) and exploiting negative correlations among Hb species (Cui et al 2010).”
MethodYücel, M. A., Selb, J., Boas, D. A., Cash, S. S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.054 · Cited by 86
“, 2007)) and methods that do not require extra measurements (such as principal component analysis, Kalman filtering, wavelet based filtering and spline interpolation (Izzetoglu et al., 2010; Molavi and Dumont, 2012; Scholkmann et al., 2010; Zhang et al., 2005)).”
Movement artefact removal from NIRS signal using multi-channel IMU data
Siddiquee, M. R., Marquez, J. S., Atri, R., Ramon, R., Perry Mayrand, R., & Bai, O. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0554-9 · Cited by 33
Metadata
- Authors
- Izzetoglu, M., Chitrapu, P., Bunce, S., & Onaral, B.
- Venue
- BioMedical Engineering OnLine
- Published
- 2010
- Volume
- 9
- Issue
- 1
- Pages
- 16
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2148895235
- Cited by
- 153
- References
- 2
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.